Pressure gauges are instruments used to measure the pressure of gases or liquids in a system.
They typically consist of a dial, a pointer, and a Bourdon tube or diaphragm that responds to changes in pressure.
They are commonly used in industrial, commercial, and residential settings to monitor and control pressure in various systems.
Examples include tire pressure gauges, boiler pressure gauges, and blood pressure gauges.
...
WIKA Group is a leading manufacturer of pressure and temperature measurement instruments.
WIKA offers a wide range of products including pressure gauges, transmitters, switches, and diaphragm seals.
Their products are used in various industries such as oil and gas, chemical, and food and beverage.
WIKA has a global presence with manufacturing facilities and sales offices in over 100 countries.
Some of their popular product...
Top trending discussions
I applied via Recruitment Consulltant and was interviewed before Dec 2021. There were 2 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Jan 2022. There was 1 interview round.
I applied via Naukri.com and was interviewed in Dec 2023. There was 1 interview round.
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
I applied via Referral and was interviewed in Oct 2023. There was 1 interview round.
Design engineers must adhere to applicable standards to ensure quality and safety of products.
Design engineers should be familiar with industry-specific standards such as ISO 9001, ASME Y14.5, and ASTM.
Adherence to standards ensures product quality, safety, and compliance with regulations.
Standards may vary depending on the industry and type of product being designed.
Regular updates and training on new standards are es
The difference between == and === is that == compares the values of two variables, while === compares both the values and the data types.
The == operator performs type coercion, meaning it converts the operands to a common type before comparison.
The === operator does not perform type coercion and requires both the values and the data types to be the same for a true comparison.
For example, 1 == '1' returns true because t...
Senior Engineer
58
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
48
salaries
| ₹0 L/yr - ₹0 L/yr |
Project Engineer
35
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
32
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Sales Engineer
26
salaries
| ₹0 L/yr - ₹0 L/yr |
EMERSON PROCESS MANAGEMENT
Endress Hauser
ABB
Siemens