I applied via Company Website and was interviewed in Jun 2024. There were 2 interview rounds.
One fault occurs in electrical panel fure same fault preventive action
Power generation involves converting mechanical energy into electrical energy using generators, which is then transmitted through power lines to reach consumers.
Power generation involves using generators to convert mechanical energy (from sources like turbines, windmills, or water wheels) into electrical energy
Generators produce electricity by rotating a coil of wire within a magnetic field, creating an electric curren...
I applied via Walk-in and was interviewed in Aug 2022. There was 1 interview round.
Precommissioning tests of transformers are essential to ensure their proper functioning.
Insulation resistance test
Turns ratio test
Vector group test
Winding resistance test
Magnetizing current test
No-load loss and excitation current test
Load loss and impedance voltage test
I applied via Company Website and was interviewed in May 2021. There were 3 interview rounds.
VCB and ACB transformers require regular maintenance to ensure optimal performance and prevent breakdowns.
Regular inspection of the transformer and its components
Cleaning of the transformer and its components
Checking and tightening of connections
Testing of protective devices
Replacement of worn out or damaged parts
Regular oil analysis
Following manufacturer's recommended maintenance schedule
Training of personnel on prope
VA Tech Wabag interview questions for designations
Top trending discussions
posted on 19 Jun 2024
posted on 2 Mar 2022
posted on 8 Apr 2022
I applied via Approached by Company and was interviewed before Apr 2021. There was 1 interview round.
I applied via Company Website and was interviewed in May 2024. There were 2 interview rounds.
CPC CABLE stands for Circuit Protective Conductor cable, which is used for earthing and providing protection against electric shock.
CPC CABLE is also known as the earth wire in electrical installations.
It is typically colored green and yellow to distinguish it from other cables.
The CPC CABLE is connected to metal parts of electrical equipment to prevent electric shock in case of a fault.
High pot test is done to check the insulation of electrical equipment.
High pot test is done to ensure the insulation in electrical equipment can withstand high voltage without breaking down.
It helps in identifying any weaknesses or defects in the insulation that could lead to electrical hazards.
The test involves applying a higher than normal voltage to the equipment to see if the insulation can handle it.
High pot testi...
HT cables are high tension cables used for transmitting electricity at high voltages.
HT cables are designed to carry high voltage electricity, typically above 11kV.
They are insulated to prevent leakage of current and ensure safety.
HT cables are usually made of materials like cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR).
They are often armored to protect against physical damage and environmental fa...
RCBO combines the functions of an RCD and a miniature circuit breaker, while RCCB and ELCB are older versions of RCDs.
RCBO combines overcurrent protection (like a circuit breaker) with earth fault protection (like an RCD)
RCCB is an older version of RCD that only detects earth faults
ELCB is an even older version of RCD that detects earth faults by measuring the current imbalance between live and neutral wires
RCBO is com...
The ten delta test is a diagnostic test used to assess the condition of power transformers.
The ten delta test measures the change in power factor between the initial and final stages of a transformer's life.
It is used to detect insulation deterioration and moisture content in the transformer oil.
Equipment used for the ten delta test includes a power factor test set, a transformer turns ratio tester, and a megohmmeter.
UPM in data centre involves managing electrical systems, ensuring uptime, and implementing energy efficiency measures.
Managing electrical systems to ensure continuous power supply
Implementing energy efficiency measures to reduce costs
Monitoring and maintaining backup power systems
Troubleshooting electrical issues to minimize downtime
Coordinating with other departments for electrical maintenance schedules
Isolation transformers are used to isolate electrical devices from the power source for safety and protection.
Isolation transformers have primary and secondary windings that are electrically separated to prevent direct current flow between the input and output.
They are commonly used in medical equipment, data centers, and sensitive electronic devices to protect them from electrical noise and voltage spikes.
Isolation tr...
posted on 19 Jun 2024
1 Interview rounds
based on 12 reviews
Rating in categories
Principal Engineer
79
salaries
| ₹7 L/yr - ₹16.5 L/yr |
Mechanical Engineer
62
salaries
| ₹2.8 L/yr - ₹7.8 L/yr |
Resident Engineer
57
salaries
| ₹6.1 L/yr - ₹13.7 L/yr |
Senior Engineer
56
salaries
| ₹5 L/yr - ₹10.5 L/yr |
Electrical Engineer
46
salaries
| ₹2.2 L/yr - ₹6.6 L/yr |
Ion Exchange India
Thermax Limited
Triveni Engineering & Industries
Kirloskar Brothers