Calibration is the process of adjusting or verifying the accuracy of a measuring instrument or device.
Calibration ensures that measurements taken by an instrument are accurate and reliable.
It involves comparing the measurements of a device to a known standard.
Calibration may involve adjusting the device to bring it in line with the standard.
It is important in various fields like engineering, manufacturing, and scientif...
Calibrating temperature indicators involves adjusting them to ensure accurate readings.
Calibration of temperature indicators involves comparing their readings to a known standard.
Adjustments are made to the indicators to align their readings with the standard.
Calibration may involve adjusting the zero point and span of the indicators.
Examples of temperature indicators include thermometers, temperature sensors, and temp
Calibration of RTDs involves comparing the sensor's output to a known reference and adjusting it accordingly.
RTDs (Resistance Temperature Detectors) are calibrated to ensure accurate temperature measurements.
Calibration involves comparing the RTD's resistance values at different temperatures to a known reference.
Adjustments are made to the RTD's output signal to align it with the reference values.
Calibration can be don...
There are several types of flow meters used in various industries to measure the flow rate of fluids or gases.
Some common types of flow meters include electromagnetic flow meters, ultrasonic flow meters, turbine flow meters, and positive displacement flow meters.
Electromagnetic flow meters use Faraday's law of electromagnetic induction to measure the flow rate of conductive fluids.
Ultrasonic flow meters utilize ultraso...
To check door interlock systems, inspect the physical components, test the electrical connections, and verify proper functioning.
Inspect the door hinges, latches, and locks for any damage or misalignment.
Check the wiring connections and ensure they are secure and not damaged.
Test the interlock switch by opening and closing the door to see if it activates properly.
Verify that the interlock system prevents the door from ...
To calibrate pressure gauges, vacuum gauges, and compound gauges, follow these steps:
Use a known reference pressure source to compare the readings of the gauges.
Adjust the gauges if there is any deviation from the reference pressure.
Repeat the process multiple times to ensure accuracy.
Document the calibration process and results for future reference.
Perform regular calibrations to maintain accuracy.
Example: For pressur...
I applied via Naukri.com and was interviewed before May 2022. There were 4 interview rounds.
Technician questions on lab instruments like as pH meter, ir, uv, kf, hplc, titration and autotitrator etc
I applied via Company Website and was interviewed before Feb 2023. There were 2 interview rounds.
It's was based on vigilance
I applied via Naukri.com and was interviewed before Jun 2020. There was 1 interview round.
posted on 19 Dec 2019
I applied via Referral and was interviewed before Dec 2018. There were 3 interview rounds.
The Ich limit for methanol is 0.6% and it is classified as a class 3 solvent.
The Ich limit for methanol refers to the maximum allowable amount of methanol in a pharmaceutical product.
The Ich limit for methanol is set at 0.6%, meaning that the concentration of methanol should not exceed 0.6% in the product.
Methanol is classified as a class 3 solvent according to the International Council for Harmonisation of Technical R...
The specification limit for known and unknown impurities varies depending on the specific substance being tested.
The specification limit for known impurities is typically set by regulatory agencies or pharmacopoeias.
For example, the United States Pharmacopeia (USP) sets limits for known impurities in pharmaceutical substances.
The specification limit for unknown impurities is usually determined through method validation...
I applied via Approached by Company and was interviewed before Jun 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Nov 2020. There was 1 interview round.
based on 1 interview
Interview experience
based on 32 reviews
Rating in categories
Senior Officer
266
salaries
| ₹3.2 L/yr - ₹8.6 L/yr |
Executive
238
salaries
| ₹3.8 L/yr - ₹10 L/yr |
Senior Executive
214
salaries
| ₹4.9 L/yr - ₹12.4 L/yr |
Officer
194
salaries
| ₹2.2 L/yr - ₹5.4 L/yr |
Assistant Manager
189
salaries
| ₹7.2 L/yr - ₹15 L/yr |
Hetero
Micro Labs
Biological E
Gland Pharma