Filter interviews by
Clear (1)
I applied via Referral and was interviewed before Dec 2023. There were 3 interview rounds.
I am a Senior Engineer with 10+ years of experience in designing and implementing complex systems.
10+ years of experience in engineering
Specialize in designing and implementing complex systems
Strong problem-solving skills
Experience with project management and team leadership
I want to join Symphony because of its reputation for innovation and collaborative work environment.
I am impressed by Symphony's track record of developing cutting-edge technology solutions.
I am excited about the opportunity to work with a team of talented engineers at Symphony.
I believe that Symphony's culture of collaboration and continuous learning aligns with my own values and career goals.
Design standards for AHU include ASHRAE standards and types of AHU include constant volume, variable air volume, and energy recovery units.
ASHRAE standards provide guidelines for the design and operation of AHUs
Types of AHU include constant volume, which deliver a constant airflow regardless of demand
Variable air volume AHUs adjust airflow based on demand to improve energy efficiency
Energy recovery units capture and re...
Psychometric test of 1 hour
Top trending discussions
I applied via Campus Placement and was interviewed before Apr 2019. There was 1 interview round.
I applied via Referral and was interviewed before Jun 2022. There were 5 interview rounds.
I applied via Apna Jobs and was interviewed in Mar 2022. There were 3 interview rounds.
I will immediately investigate the cause of the NG lot and work with the team to find a solution to make it usable.
Investigate the cause of the NG lot
Work with the team to find a solution
Prioritize urgent use of the lot
Ensure quality control measures are in place
Communicate with stakeholders about the situation
I applied via Approached by Company and was interviewed before Jun 2022. There were 5 interview rounds.
Sub cooling in air conditioning is the process of cooling the refrigerant below its saturation temperature to improve system efficiency.
Sub cooling increases the efficiency of the air conditioning system by ensuring the refrigerant is in a liquid state before entering the expansion valve.
It helps in preventing flash evaporation of the refrigerant, which can lead to inefficiencies in the system.
Sub cooling is typically ...
ISEER rating is calculated based on the weighted average of the cooling performance of an air conditioner under different conditions.
ISEER = (Weighted Cooling Capacity at 100% load x 0.4) + (Weighted Cooling Capacity at 75% load x 0.2) + (Weighted Cooling Capacity at 50% load x 0.4)
The higher the ISEER rating, the more energy efficient the air conditioner is.
ISEER rating helps consumers compare the energy efficiency of...
The refrigeration cycle is a thermodynamic cycle used in refrigerators and air conditioning systems to transfer heat from a low temperature to a high temperature environment.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant enters the compressor as a low-pressure gas and leaves as a high-pressure, high-temperature gas.
The high-pressure gas then flows into...
Mainstream refrigerants used in household air conditioning include R-410A, R-22, and R-134a.
R-410A is a popular refrigerant known for its high efficiency and environmental friendliness.
R-22, although being phased out due to its ozone-depleting properties, is still commonly found in older air conditioning systems.
R-134a is commonly used in automotive air conditioning systems but can also be found in some household units
1 ton cooling concept refers to the amount of heat required to melt one ton of ice in a 24-hour period.
1 ton of cooling is equal to 12,000 BTUs per hour
It is commonly used in the HVAC industry to measure the cooling capacity of air conditioning systems
For example, a 2-ton air conditioner can remove 24,000 BTUs of heat per hour
The relationship between current, voltage, and power is described by Ohm's Law, which states that current is directly proportional to voltage and inversely proportional to resistance.
Ohm's Law states that V = I * R, where V is voltage, I is current, and R is resistance.
Power (P) is calculated using the formula P = V * I, where P is power, V is voltage, and I is current.
In a circuit with a constant resistance, an increa...
1 BTU is approximately equal to 0.29307107 watts. To convert BTU to watts, multiply by 0.29307107. To convert watts to BTU, divide by 0.29307107.
1 BTU = 0.29307107 watts
To convert BTU to watts, multiply by 0.29307107
To convert watts to BTU, divide by 0.29307107
I was interviewed before Feb 2024.
I applied via Recruitment Consulltant and was interviewed before Jan 2021. There were 4 interview rounds.
I applied via Naukri.com and was interviewed before Sep 2021. There were 2 interview rounds.
based on 2 interviews
Interview experience
Area Business Head
49
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Territory Sales Executive
32
salaries
| ₹0 L/yr - ₹0 L/yr |
Area Sales Manager
18
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
15
salaries
| ₹0 L/yr - ₹0 L/yr |
Territory Sales Head
15
salaries
| ₹0 L/yr - ₹0 L/yr |
Blue Star
Voltas
Havells
Whirlpool