Add office photos
Employer?
Claim Account for FREE

Symed Labs

3.9
based on 122 Reviews
Filter interviews by

10+ Alfanar Interview Questions and Answers

Updated 25 Apr 2024

Q1. What. Is the range of UV , make and principle ?How to do UV Calibration with briefly?

Ans.

UV range is 190-400 nm, common makes include Agilent and Shimadzu, principle is based on absorption of UV light. UV calibration involves using standard solutions and adjusting wavelength and absorbance.

  • UV range typically falls between 190-400 nm

  • Common makes of UV instruments include Agilent and Shimadzu

  • Principle of UV analysis is based on the absorption of UV light by the sample

  • UV calibration involves using standard solutions of known concentrations

  • Calibration includes adjust...read more

Add your answer

Q2. Why are the using for the DST and Methanol in KF titration (reason for uses)

Ans.

DST is used to break down the sample matrix and release water for titration, while Methanol is used as a solvent for the sample.

  • DST (Di Sodium Tartrate) is used to break down the sample matrix and release water molecules for titration.

  • Methanol is used as a solvent to dissolve the sample and ensure accurate titration results.

  • Both DST and Methanol help in ensuring precise and reliable Karl Fischer titration results.

Add your answer

Q3. How to identify functional group in IR spectroscopy and make also

Ans.

Functional groups in IR spectroscopy can be identified by analyzing characteristic peaks in the spectrum and comparing them to reference data.

  • Identify the presence of functional groups by looking for specific peaks in the IR spectrum

  • Use reference tables or databases to match the observed peaks with known functional groups

  • Look for characteristic peaks such as C=O stretch for carbonyl groups, O-H stretch for alcohols, and N-H stretch for amines

  • Consider the intensity and positio...read more

Add your answer

Q4. What are the chemical using in Melting point calibration with Ranges

Ans.

Chemicals commonly used in melting point calibration include naphthalene, benzophenone, and biphenyl.

  • Naphthalene is commonly used as a primary standard for melting point calibration.

  • Benzophenone is used as a secondary standard for melting point calibration.

  • Biphenyl is another common chemical used for melting point calibration.

  • Mixtures of these chemicals can also be used to create calibration standards with specific melting point ranges.

Add your answer
Discover Alfanar interview dos and don'ts from real experiences

Q5. What are the chemical in KF Reagent solutions like formation and make also

Ans.

KF Reagent solutions contain chemicals like methanol, sulfur dioxide, and iodine in specific ratios for accurate moisture determination.

  • KF Reagent solutions typically contain methanol as a solvent

  • Sulfur dioxide is added to prevent side reactions

  • Iodine is the titrant used in the Karl Fischer titration method

  • The chemicals in KF Reagent solutions are carefully balanced to ensure accurate moisture determination

Add your answer

Q6. What type of pH using and explain about calibration

Ans.

I use a pH meter for testing and calibrate it regularly to ensure accurate results.

  • I use a pH meter to measure the acidity or alkalinity of a solution.

  • Calibration involves adjusting the pH meter to ensure accurate readings.

  • I calibrate the pH meter using buffer solutions of known pH levels.

  • Regular calibration is important to maintain the accuracy of the pH meter.

  • Examples of buffer solutions used for calibration include pH 4.01, 7.00, and 10.01 solutions.

Add your answer

Q7. Explain about calibration of polarimeter and why are using sucrose

Ans.

Calibration of polarimeter is essential for accurate measurements. Sucrose is commonly used as it has a known specific rotation.

  • Calibration of polarimeter involves adjusting the instrument to ensure accurate readings.

  • Sucrose is often used for calibration as it has a well-known specific rotation value.

  • By calibrating the polarimeter with sucrose, the instrument can accurately measure the specific rotation of other substances.

  • Regular calibration ensures the reliability and accur...read more

Add your answer

Q8. Why are using muffler furnace with Range Why are using H2SO4

Ans.

Muffler furnace is used for controlled heating and H2SO4 is used for acid digestion in analytical testing.

  • Muffler furnace provides controlled heating for accurate analysis of samples

  • H2SO4 is used for acid digestion to break down samples for analysis

  • Both tools are essential for accurate and precise analytical testing

Add your answer

Q9. How can you manage when work pressure is there?

Ans.

I manage work pressure by prioritizing tasks, taking breaks, and seeking support when needed.

  • I prioritize tasks based on urgency and importance

  • I take short breaks to recharge and refocus

  • I seek support from colleagues or supervisors when necessary

  • I practice stress-reducing techniques such as deep breathing or meditation

  • I maintain a healthy work-life balance to prevent burnout

Add your answer

Q10. ICH guidelines and regulations

Ans.

ICH guidelines and regulations are international standards for the quality, safety, and efficacy of pharmaceutical products.

  • ICH stands for International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use

  • Guidelines cover topics such as clinical trials, pharmacovigilance, and quality management

  • Regulations ensure consistency in drug development and approval processes across different regions

  • Examples include ICH E6 for Good Clinical Practice and...read more

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories

Top Interview Questions from Similar Companies

4.2
 • 288 Interview Questions
3.7
 • 264 Interview Questions
4.0
 • 192 Interview Questions
3.6
 • 178 Interview Questions
3.4
 • 167 Interview Questions
4.1
 • 154 Interview Questions
View all
Top Symed Labs Interview Questions And Answers
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions
Get AmbitionBox app

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter