Filter interviews by
Top trending discussions
I applied via Approached by Company and was interviewed before Apr 2021. There were 2 interview rounds.
Group discussion
Coding test
posted on 11 Jun 2021
We are delivering electrical products and equipment for various industries and applications.
Our products include transformers, switchgear, motors, and control panels.
We provide electrical solutions for industries such as manufacturing, construction, and energy.
Our equipment is responsible for powering machinery, lighting, and other electrical systems.
We ensure that all our products meet safety standards and are install...
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
It is a measure of how efficiently electrical power is being used.
It ranges from 0 to 1, with 1 being the most efficient.
A low power factor can result in higher energy costs and equipment damage.
Capacitors can be used to improve power factor.
Example: A motor with a power factor of 0.8 requires 1.25 times more current than a motor with a power fa
I applied via Company Website and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
33 kV to 220 SLD refers to a switchgear system for electrical distribution at medium voltage levels.
33 kV to 220 SLD likely refers to a switchgear system designed to handle voltages between 33 kV and 220 kV.
SLD stands for Single Line Diagram, which is a schematic representation of the electrical distribution system.
This switchgear system would be used for distributing electricity from a higher voltage transmission syst...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that operates in the air where the arc is drawn in the air and extinguished using air.
VCB is a type of circuit breaker that operates in a vacuum where the arc is drawn in a vacuum and extinguished using vacuum.
ACBs are commonly used in low voltage applications while VCBs are used in medium voltage applications.
...
I applied via Naukri.com and was interviewed in May 2022. There were 5 interview rounds.
Psychometric test on pc
I appeared for an interview in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
I applied via Referral and was interviewed before Mar 2023. There were 2 interview rounds.
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Technical Supervisor
47
salaries
| ₹2 L/yr - ₹4.1 L/yr |
Electrical Supervisor
23
salaries
| ₹2 L/yr - ₹3.5 L/yr |
Electrical Technician
22
salaries
| ₹1.9 L/yr - ₹3 L/yr |
Multi Skill Technician
19
salaries
| ₹1.4 L/yr - ₹3 L/yr |
Electrical Maintenance Engineer
12
salaries
| ₹2.7 L/yr - ₹3.5 L/yr |
Sodexo
ISS Facility Services
BVG India
Leadec India