Slump test is a method to measure the workability of concrete by observing the consistency and flow of the concrete mix.
Prepare a slump cone by lubricating the inside surface and placing it on a smooth, flat surface.
Fill the cone with concrete in three layers, each layer tamped with a rod 25 times.
Remove excess concrete, level the top, and lift the cone vertically. Measure the slump of the concrete.
Record the slump mea...
To fill a cube, ensure all sides are properly aligned and filled with the material. Check for any gaps or air pockets.
Ensure the cube mold is clean and dry before filling.
Pour the material into the mold slowly and evenly to prevent air pockets.
Use a vibrating table to help settle the material and remove any air bubbles.
Check for any leaks or cracks in the mold before filling to prevent material from leaking out.
After f...
The test is very difficult you have to complete all 20 questions which consist GC , subject related
A wave trap is a device used in electrical engineering to prevent unwanted signals or frequencies from entering a system.
Wave traps are typically used in power systems to filter out specific frequencies that can cause interference.
They are designed to allow only desired signals to pass through while blocking unwanted signals.
Wave traps can be used in substations, transmission lines, and other electrical systems to impr...
Types of circuit breakers used in substations include air circuit breakers, oil circuit breakers, vacuum circuit breakers, and SF6 circuit breakers.
Air circuit breakers are commonly used in low voltage applications.
Oil circuit breakers are used in high voltage applications.
Vacuum circuit breakers are compact and reliable, suitable for medium voltage applications.
SF6 circuit breakers are used in high voltage substations
Global warming ,covid-19, current affairs
posted on 12 Oct 2023
I applied via Recruitment Consulltant and was interviewed in Sep 2023. There were 2 interview rounds.
Quality lab and site test of concrete involves testing the strength, durability, and consistency of concrete samples.
Quality lab tests include compressive strength test, slump test, air content test, and temperature test.
Site tests involve sampling concrete from the construction site, conducting field tests like slump test and air content test, and monitoring curing conditions.
Quality engineers ensure that concrete mee...
I applied via Recruitment Consulltant and was interviewed in Aug 2023. There were 2 interview rounds.
Types of compressors include reciprocating, rotary, centrifugal, and axial compressors.
Reciprocating compressors use pistons to compress air or gas.
Rotary compressors use rotating mechanisms such as screws or vanes.
Centrifugal compressors use a rotating impeller to create centrifugal force.
Axial compressors use rotating blades to compress air in a straight line.
Examples include reciprocating air compressors, rotary scr...
The procedure to install centrifugal axial compressors involves proper planning, alignment, assembly, and testing.
Ensure proper foundation is prepared to support the compressor
Align the compressor with the piping system for proper flow
Assemble the compressor components according to manufacturer's instructions
Test the compressor for performance and efficiency before final installation
Types of pumps include centrifugal, positive displacement, and axial flow pumps.
Centrifugal pumps: use centrifugal force to move fluid through the pump
Positive displacement pumps: move fluid by trapping a fixed amount and forcing it through the discharge port
Axial flow pumps: move fluid parallel to the pump shaft
A lifting plan procedure is a detailed plan outlining the steps and precautions to be taken when lifting heavy objects.
Identify the weight and dimensions of the object to be lifted
Determine the appropriate lifting equipment needed
Assess the location and environment for any obstacles or hazards
Assign roles and responsibilities to team members involved in the lift
Communicate clearly and follow the plan step by step
Conduc...
Pumps capacity refers to the maximum flow rate a pump can handle.
Pumps capacity is typically measured in gallons per minute (GPM) or liters per minute (LPM).
It is important to consider the required flow rate when selecting a pump for a specific application.
Factors such as pump size, motor power, and system pressure affect the capacity of a pump.
For example, a centrifugal pump may have a capacity of 500 GPM, while a dia
Methods statement for maintaining rotating and static equipment in mechanical engineering.
Regular inspection and maintenance schedules for both rotating and static equipment
Use of proper lubrication for rotating equipment to prevent wear and tear
Checking alignment and balance of rotating equipment to ensure smooth operation
Testing and calibrating static equipment for accuracy and efficiency
Following manufacturer's guid...
posted on 22 Apr 2024
I applied via Approached by Company and was interviewed in Mar 2024. There was 1 interview round.
posted on 6 Jun 2024
QA (Quality Assurance) focuses on preventing defects in the process, while QC (Quality Control) focuses on identifying defects in the product.
QA involves processes and procedures to ensure quality standards are met
QC involves testing and inspection to identify defects in the product
Example: QA - creating test plans, QC - executing test cases
posted on 3 May 2023
posted on 16 Feb 2024
Concrete temperature refers to the temperature of freshly mixed concrete before it sets.
Concrete temperature affects the setting time and strength development of concrete.
It is important to monitor and control the temperature of concrete during mixing, transportation, and placement.
The ideal temperature range for concrete is typically between 50-75 degrees Fahrenheit.
Extreme temperatures can lead to issues such as ther...
posted on 13 Aug 2021
I was interviewed in Jul 2022.
based on 4 reviews
Rating in categories
Civil Site Engineer
67
salaries
| ₹2.1 L/yr - ₹7 L/yr |
Site Engineer
62
salaries
| ₹2 L/yr - ₹6 L/yr |
Civil Engineer
44
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Senior Engineer
33
salaries
| ₹3.2 L/yr - ₹11.5 L/yr |
Mechanical Engineer
30
salaries
| ₹2.4 L/yr - ₹6 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
Punj Lloyd