i
Raychem RPG
Filter interviews by
I applied via Naukri.com and was interviewed in Feb 2024. There were 2 interview rounds.
PPAP stands for Production Part Approval Process.
PPAP is a standardized process in the automotive industry to ensure that suppliers can consistently deliver high-quality parts.
It involves submitting documentation such as design records, process flow diagrams, control plans, and measurement system analysis.
PPAP is typically required for new parts or parts with design changes.
The goal of PPAP is to demonstrate that the s...
APQP stands for Advanced Product Quality Planning. It is a structured method for developing and introducing new products and processes.
APQP is a framework used in the automotive industry to ensure quality and reliability of new products.
It involves defining and documenting the steps needed to ensure that a product satisfies the customer.
APQP includes activities such as design and process FMEAs, control plans, and produ
Top trending discussions
I applied via Naukri.com and was interviewed before Jun 2020. There was 1 interview round.
MCB components are typically made of materials such as copper, silver, thermoplastics, and ceramics.
Copper is commonly used for conducting electricity in MCBs.
Silver is sometimes used as a contact material for better conductivity.
Thermoplastics like polyamide are used for insulation and housing of MCB components.
Ceramics are used for arc chutes to extinguish the arc when the MCB trips.
Other materials like steel, brass,...
posted on 24 Apr 2021
I applied via Naukri.com and was interviewed before Apr 2020. There were 3 interview rounds.
I applied via Campus Placement and was interviewed before Apr 2019. There was 1 interview round.
I applied via Walk-in and was interviewed before Apr 2021. There were 3 interview rounds.
Basic
posted on 5 Nov 2023
I applied via Naukri.com and was interviewed in May 2023. There were 3 interview rounds.
Electrical testing for equipment involves verifying functionality and safety through various tests.
Perform insulation resistance tests to check for any leakage currents
Conduct continuity tests to ensure proper electrical connections
Verify voltage and current ratings are within acceptable limits
Test for proper grounding to prevent electrical hazards
Use specialized equipment like multimeters and insulation testers
Documen
Different cable types have varying current carrying capacities and methods of laying, impacting overall electrical system performance.
Different cable types such as PVC, XLPE, and rubber have different current carrying capacities.
Current carrying capacity is influenced by factors like conductor size, insulation material, and ambient temperature.
Methods of laying cables include direct burial, conduit installation, and ov...
I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.
I applied via Company Website and was interviewed in Jul 2021. There were 3 interview rounds.
based on 1 interview
Interview experience
Assistant Manager
133
salaries
| ₹5.7 L/yr - ₹15.5 L/yr |
Senior Executive
102
salaries
| ₹4.5 L/yr - ₹10.1 L/yr |
Deputy Manager
53
salaries
| ₹8.6 L/yr - ₹18.3 L/yr |
Executive
50
salaries
| ₹3.2 L/yr - ₹9 L/yr |
Quality Inspector
43
salaries
| ₹1.3 L/yr - ₹3 L/yr |
Havells
Polycab Wires
CG Power and Industrial Solutions
C&S Electric