Power factor is a measure of how effectively electrical power is being used in a circuit.
Power factor is the ratio of real power to apparent power in an electrical circuit.
It is a number between 0 and 1, with 1 representing perfect efficiency.
A low power factor indicates that a circuit is not using electrical power efficiently.
Power factor can be improved by adding power factor correction capacitors to the circuit.
It i...
Primary winding receives electrical energy from the source while secondary winding delivers the transformed energy to the load.
Primary winding is connected to the input voltage source
Secondary winding is connected to the load
Primary winding has fewer turns than secondary winding to step up voltage
Secondary winding has more turns than primary winding to step down voltage
I was interviewed before Sep 2021.
I applied via Naukri.com and was interviewed in Mar 2021. There were 3 interview rounds.
Preventive maintenance involves scheduled inspections and repairs to prevent equipment failure. MTTR and MTBF are used to measure equipment reliability. PLC interlock with ladder logic ensures safe operation.
Preventive maintenance involves regular inspections and repairs to prevent equipment failure
MTTR (Mean Time to Repair) measures the average time it takes to repair equipment
MTBF (Mean Time Between Failures) measure...
1st angle projection is commonly used in the United States, while 3rd angle projection is more commonly used in Europe and Asia.
1st angle projection places the object in the first quadrant, with the front view on the right and the top view on top.
3rd angle projection places the object in the third quadrant, with the front view on the left and the top view on top.
1st angle projection is commonly used in the United State...
Two-stroke engines have a power stroke every revolution, while four-stroke engines have a power stroke every other revolution.
Two-stroke engines have a simpler design with fewer moving parts compared to four-stroke engines.
Two-stroke engines require a fuel-oil mixture for lubrication, while four-stroke engines have a separate oil system.
Two-stroke engines are lighter and have a higher power-to-weight ratio than four-st...
5S is a workplace organization method, Kaizen is continuous improvement, and Poka Yoke is error-proofing.
5S types refer to Sort, Set in order, Shine, Standardize, and Sustain for workplace organization.
Kaizen is a Japanese term for continuous improvement in processes and products.
Poka Yoke is a mistake-proofing technique to prevent errors in manufacturing processes.
Example: Implementing 5S in a factory to improve effic...
SQTCM stands for Software Quality Testing and Control Management. It is a process that ensures software products meet quality standards.
SQTCM involves creating test plans and test cases to ensure software functionality meets requirements
It includes conducting various types of testing such as unit testing, integration testing, and system testing
SQTCM also involves tracking defects and issues found during testing and ens
posted on 11 Oct 2020
I applied via Naukri.com and was interviewed in Sep 2020. There was 1 interview round.
posted on 14 Sep 2023
I applied via Naukri.com and was interviewed before Sep 2022. There were 3 interview rounds.
Diagrammatically Reasoning questions ask him
posted on 7 Aug 2024
3 phase power has three conductors carrying three alternating currents, while 1 phase power has only one conductor carrying one alternating current.
3 phase power is more efficient for high power applications
1 phase power is commonly used in residential buildings
3 phase power provides a more balanced power supply compared to 1 phase power
kW is a unit of real power while kVA is a unit of apparent power in electrical engineering.
kW stands for kilowatts and represents the actual power consumed by a device or system.
kVA stands for kilovolt-amperes and represents the total power in an electrical system, including both real and reactive power.
The difference between kW and kVA is due to the presence of reactive power in the system.
In an ideal system with unit...
Transformer works on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.
Transformers consist of two coils of wire, known as the primary and secondary coils.
When an alternating current flows through the primary coil, it creates a changing magnetic field around it.
This changing magnetic field induces a voltage in the secondary coil, transferring electrical energy between...
Types of AC motors include induction motors, synchronous motors, and brushed and brushless DC motors.
Induction motors: most commonly used type, simple design, reliable, low cost
Synchronous motors: maintain constant speed, used in applications requiring precise speed control
Brushed DC motors: use brushes to conduct current, simple design, easy to control speed
Brushless DC motors: more efficient, longer lifespan, no brus
posted on 17 Mar 2022
I applied via Approached by Company and was interviewed in Sep 2021. There were 2 interview rounds.
I applied via Recruitment Consultant and was interviewed before Mar 2019. There were 4 interview rounds.
posted on 15 Dec 2019
I applied via Naukri.com and was interviewed in Jul 2019. There were 5 interview rounds.
based on 1 interview
Interview experience
Junior Engineer
27
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
14
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
13
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
12
salaries
| ₹0 L/yr - ₹0 L/yr |
Production Engineer
11
salaries
| ₹0 L/yr - ₹0 L/yr |
Becton Dickinson
Romsons Group Of Industries
Essilor
SMC Corporation