Filter interviews by
Voltage is the potential difference between two points in an electrical circuit, while current is the flow of electric charge through a conductor.
Voltage is measured in volts (V) and current is measured in amperes (A).
Voltage is the driving force that pushes current through a circuit.
Ohm's Law states that voltage is equal to current multiplied by resistance (V=IR).
Voltage can be stepped up or down using transformers, w...
E-Plan, AutoCAD, and E-CAD are all software used in electrical design engineering, but they have differences.
E-Plan is a specialized software for electrical engineering design and documentation.
AutoCAD is a general-purpose computer-aided design (CAD) software used in various industries.
E-CAD refers to the use of CAD software specifically for electronic design and circuit board layout.
E-Plan focuses on electrical schema...
CT and PT are used for current and voltage measurement respectively. Primary winding is connected to the source and secondary to the load.
CT measures the current flowing in a circuit and steps down the current to a level that can be measured by an ammeter
PT measures the voltage of a circuit and steps down the voltage to a level that can be measured by a voltmeter
Primary winding is connected to the source and secondary ...
Pragati Electricals is a company that specializes in electrical design and engineering services.
Provides electrical design and engineering services
Offers solutions for power distribution, lighting, and control systems
Works with clients in various industries such as commercial, industrial, and residential
Has a team of experienced electrical engineers and designers
Uses advanced software and technology to ensure high-qual
Top trending discussions
I applied via Company Website and was interviewed in Aug 2022. There were 3 interview rounds.
Technical parameters with respect to electrical like standards, parameters, basic calculations and knowledge about plc and drives wrt material handling systems
posted on 13 Apr 2020
I applied via Recruitment Consultant and was interviewed in Oct 2019. There was 1 interview round.
SCCR stands for Short-Circuit Current Rating.
SCCR is a measure of the maximum amount of current that a device or system can safely withstand during a short circuit.
It is an important consideration in electrical design to ensure the protection of equipment and personnel.
SCCR is typically expressed in amperes (A) and is determined through testing or calculations.
It helps in selecting appropriate protective devices such a...
OLR setting in a star-delta connection determines the transition point between star and delta mode.
OLR stands for Overload Relay.
In a star-delta connection, the motor is initially started in star mode to reduce the starting current.
After a certain time, the motor is switched to delta mode for normal operation.
The OLR setting determines the current threshold at which the transition from star to delta occurs.
The OLR sett...
HRC fuse stands for High Rupturing Capacity fuse. It is a type of fuse that is designed to safely interrupt high fault currents.
HRC fuse is used in electrical systems to protect against overcurrents and short circuits.
It has a high breaking capacity, which means it can safely interrupt high fault currents without causing damage.
The fuse contains a fuse element made of a material that can withstand high temperatures and...
The two earthing terminals in a motor provide redundancy and ensure safety in case of a fault.
The first earthing terminal is connected to the motor frame, providing a path for fault current to flow and preventing electric shock to personnel.
The second earthing terminal is connected to the motor winding, providing a path for fault current to flow and protecting the motor from damage.
Having two earthing terminals ensures...
posted on 11 Oct 2020
I applied via Recruitment Consultant and was interviewed before Oct 2019. There was 1 interview round.
posted on 24 Jan 2023
I applied via Walk-in
I applied via Company Website and was interviewed in Aug 2022. There were 3 interview rounds.
Technical parameters with respect to electrical like standards, parameters, basic calculations and knowledge about plc and drives wrt material handling systems
posted on 2 Jun 2022
I applied via Naukri.com and was interviewed in May 2022. There were 3 interview rounds.
posted on 13 Apr 2020
I applied via Recruitment Consultant and was interviewed in Oct 2019. There was 1 interview round.
SCCR stands for Short-Circuit Current Rating.
SCCR is a measure of the maximum amount of current that a device or system can safely withstand during a short circuit.
It is an important consideration in electrical design to ensure the protection of equipment and personnel.
SCCR is typically expressed in amperes (A) and is determined through testing or calculations.
It helps in selecting appropriate protective devices such a...
OLR setting in a star-delta connection determines the transition point between star and delta mode.
OLR stands for Overload Relay.
In a star-delta connection, the motor is initially started in star mode to reduce the starting current.
After a certain time, the motor is switched to delta mode for normal operation.
The OLR setting determines the current threshold at which the transition from star to delta occurs.
The OLR sett...
HRC fuse stands for High Rupturing Capacity fuse. It is a type of fuse that is designed to safely interrupt high fault currents.
HRC fuse is used in electrical systems to protect against overcurrents and short circuits.
It has a high breaking capacity, which means it can safely interrupt high fault currents without causing damage.
The fuse contains a fuse element made of a material that can withstand high temperatures and...
The two earthing terminals in a motor provide redundancy and ensure safety in case of a fault.
The first earthing terminal is connected to the motor frame, providing a path for fault current to flow and preventing electric shock to personnel.
The second earthing terminal is connected to the motor winding, providing a path for fault current to flow and protecting the motor from damage.
Having two earthing terminals ensures...
posted on 11 Oct 2020
I applied via Recruitment Consultant and was interviewed before Oct 2019. There was 1 interview round.
based on 1 review
Rating in categories
Design Engineer
21
salaries
| ₹1.2 L/yr - ₹3.7 L/yr |
Transformer Testing Engineer
7
salaries
| ₹1.8 L/yr - ₹2.2 L/yr |
Draughtsman Mechanical
7
salaries
| ₹1.1 L/yr - ₹3 L/yr |
Quality Engineer
7
salaries
| ₹1.7 L/yr - ₹2.8 L/yr |
Test Engineer
7
salaries
| ₹1.5 L/yr - ₹2.2 L/yr |
Siemens
ABB