Filter interviews by
Be the first one to contribute and help others!
posted on 27 Jan 2025
Diesel Generator: A Reliable Power Source
A diesel generator is a self-contained power generating unit that combines a diesel engine with an electric generator (often an alternator). It's a versatile and widely used source of electricity, particularly in situations where a reliable power supply is crucial.
How Diesel Generators Work
* Diesel Engine: The diesel engine, fueled by diesel fuel, acts as the prime mover. It converts the chemical energy of the fuel into mechanical energy through combustion.
* Electric Generator: The mechanical energy from the engine is transferred to the generator, which converts it into electrical energy. This electrical energy can then be used to power various appliances and equipment.
Applications of Diesel Generators
* Backup Power: Diesel generators are commonly used as backup power sources for homes, businesses, hospitals, and critical infrastructure during power outages.
* Remote Locations: In areas with limited or no access to the grid, diesel generators provide a reliable source of electricity for various applications.
* Construction Sites: Diesel generators power tools and equipment on construction sites, ensuring work can continue even in remote locations.
* Off-Grid Living: Individuals living off the grid often rely on diesel generators for their electricity needs.
* Data Centers: Diesel generators provide backup power to ensure the continuous operation of critical data centers.
Advantages of Diesel Generators
* Reliability: Diesel engines are known for their durability and reliability, making them suitable for demanding applications.
* Fuel Efficiency: Modern diesel engines offer excellent fuel efficiency, reducing operating costs.
* Wide Power Range: Diesel generators are available in a wide range of sizes and power capacities, catering to various needs.
* Easy Maintenance: Diesel generators are relatively easy to maintain and service.
Disadvantages of Diesel Generators
* Noise: Diesel generators can be noisy, which may be a concern in certain settings.
Panel and protection systems are essential components in electrical engineering for controlling and safeguarding electrical circuits.
Different types of panels include distribution panels, control panels, and instrumentation panels.
Protection systems include overcurrent protection, earth fault protection, and differential protection.
Panels are used to house electrical components and provide a safe environment for operat...
posted on 27 Feb 2025
posted on 25 Feb 2025
posted on 15 Jan 2025
I applied via AmbitionBox and was interviewed in Dec 2024. There were 5 interview rounds.
An overload relay works by monitoring the current flowing through a motor and tripping when the current exceeds a set limit.
Monitors the current flowing through a motor
Trips and interrupts power when current exceeds a set limit
Protects the motor from damage due to overloading
Can be reset manually after tripping
Insulation resistance is measured using a megohmmeter to apply a high voltage and measure the resistance of the insulation material.
Use a megohmmeter to apply a high voltage to the insulation material
Measure the resistance of the insulation material to determine its insulation resistance
Insulation resistance is typically measured in megaohms (MΩ)
Regular insulation resistance testing helps prevent electrical failures an
Electrical safety can be ensured by following proper procedures, using appropriate equipment, and staying vigilant.
Always use insulated tools when working on live circuits
Ensure circuits are de-energized before working on them
Wear appropriate personal protective equipment (PPE) such as gloves and goggles
Regularly inspect and maintain electrical equipment to prevent malfunctions
Follow safety guidelines and procedures ou
Preventive maintenance on a motor involves inspecting, cleaning, lubricating, and testing the motor to ensure optimal performance and prevent breakdowns.
Inspect the motor for any signs of wear or damage
Clean the motor and its components to remove dirt and debris
Lubricate moving parts to reduce friction and wear
Test the motor's performance using appropriate tools and equipment
Replace any worn out parts or components as
To succeed in an interview, it is important to prepare thoroughly, practice common interview questions, research the company, dress professionally, and demonstrate enthusiasm and confidence.
Thoroughly research the company and the position you are applying for
Practice common interview questions and prepare examples of your skills and experiences
Dress professionally and appropriately for the interview
Demonstrate enthusia...
A star-delta starter is used to reduce the starting current of a motor by initially connecting the motor windings in a star configuration and then switching to a delta configuration.
The motor windings are initially connected in a star configuration during starting to reduce the starting current.
After a certain period, the windings are switched to a delta configuration to achieve full speed and torque.
This transition fr...
Undervoltage faults occur when the voltage in a system drops below the normal operating level, leading to potential equipment damage or malfunction.
Undervoltage faults can be caused by issues such as power supply fluctuations, equipment failures, or overloaded circuits.
These faults can lead to equipment damage, reduced efficiency, or complete shutdown of systems.
Examples include a power surge causing a drop in voltage,...
Overvoltage faults are electrical faults that occur when the voltage in a circuit exceeds the normal operating range.
Overvoltage faults can damage electrical components and equipment.
They can be caused by lightning strikes, power surges, or faulty equipment.
Protective devices like surge protectors and voltage regulators can help prevent overvoltage faults.
Examples include a power surge from a lightning strike damaging ...
A thermal relay is used to protect electrical circuits from overloads by monitoring the temperature of the circuit and tripping when it exceeds a certain threshold.
Monitors the temperature of the electrical circuit
Trips and disconnects the circuit when temperature exceeds a set limit
Protects against overloads and overheating
Commonly used in motor protection applications
An RDOL starter is a type of reduced voltage starter used in electrical systems to reduce the starting current and torque of a motor.
RDOL stands for Reduced Direct Online starter.
It is used to start induction motors in a controlled manner.
RDOL starters reduce the voltage supplied to the motor during starting to limit the inrush current.
This helps in reducing mechanical stress on the motor and connected equipment.
Common...
posted on 22 Jan 2025
Bachelor of Commerce degree with a GPA of 6.79 and an accompanying resume.
I was interviewed in Jan 2025.
I applied via Campus Placement
It was a technicaL + aptitude test with 60 minutes duration.
posted on 27 Jan 2025
ICP-OES stands for Inductively Coupled Plasma - Optical Emission Spectroscopy, used for elemental analysis in various industries.
ICP-OES is a technique used for elemental analysis in various industries such as environmental, pharmaceutical, and food testing.
It works by ionizing the sample in an inductively coupled plasma and then measuring the emitted light at specific wavelengths.
Troubleshooting of ICP-OES involves ch...
The type of titration refers to the method used to determine the concentration of a substance in a solution by reacting it with a known volume and concentration of another substance.
There are different types of titrations such as acid-base titrations, redox titrations, and complexometric titrations.
In acid-base titrations, the pH of the solution is monitored to determine the endpoint of the reaction.
Redox titrations in...
based on 18 reviews
Rating in categories
Mechanical Maintenance Engineer
6
salaries
| ₹2.5 L/yr - ₹5.2 L/yr |
Assistant Manager
5
salaries
| ₹6 L/yr - ₹6.8 L/yr |
Engineer
5
salaries
| ₹2.5 L/yr - ₹6 L/yr |
Senior Engineer
5
salaries
| ₹4.2 L/yr - ₹5 L/yr |
Manager
4
salaries
| ₹8.2 L/yr - ₹10.8 L/yr |
Larsen & Toubro Limited
Tata Steel
Shapoorji Pallonji Group
Cummins