Q1. area classification as per USFDA guidelines and ISO guidelines
Area classification is the process of determining the cleanliness level required for different areas in a pharmaceutical facility.
USFDA guidelines classify areas into four categories: A, B, C, and D based on the level of cleanliness required.
ISO guidelines classify areas into different classes such as ISO 5, ISO 7, and ISO 8 based on particle count limits.
The classification of areas is crucial for maintaining the quality of pharmaceutical products and ensuring compliance with...read more
Q2. What is filter integrity test and how to do.
Filter integrity test is a method to ensure the filter is functioning properly by testing its ability to retain particles of a certain size.
Filter integrity test is performed to verify the effectiveness of a filter in retaining particles of a specific size.
Common methods include bubble point test, diffusion test, pressure hold test, and water intrusion test.
The test results are compared against established acceptance criteria to determine if the filter is functioning properly...read more
Q3. How can perform PAO test. And concentration ratio
Performing PAO test involves measuring the concentration ratio of a substance in a solution.
Prepare a known concentration of the substance to be tested
Measure the absorbance of the solution at a specific wavelength using a spectrophotometer
Plot a standard curve using known concentrations of the substance
Calculate the concentration of the unknown sample using the standard curve
Concentration ratio can be calculated by dividing the concentration of the substance in the solution ...read more
Q4. How can calculate HVAC efficiency
HVAC efficiency can be calculated by dividing the useful output by the total input.
Calculate the useful output of the HVAC system, such as the amount of heating or cooling provided to the space.
Determine the total input of the HVAC system, including the energy consumed by the system.
Divide the useful output by the total input to get the efficiency percentage.
Efficiency (%) = (Useful Output / Total Input) * 100
For example, if a HVAC system provides 10,000 BTUs of cooling while...read more
Q5. What is DX coil
DX coil is a type of coil used in air conditioning systems to transfer heat between the indoor and outdoor units.
DX coil stands for Direct Expansion coil
It is a key component in air conditioning systems
DX coils are used to transfer heat between the refrigerant and the air being circulated in the system
They are commonly found in split air conditioning systems
Q6. Class ISO 7 partical count
ISO 7 particle count refers to the cleanliness level of air in a controlled environment.
ISO 7 classifies air cleanliness based on the number of particles per cubic meter.
Lower particle counts indicate cleaner air and higher particle counts indicate more contamination.
ISO 7 is commonly used in cleanrooms and controlled environments to maintain quality standards.
Example: ISO 7 particle count may be 10,000 particles per cubic meter.