LEL stands for Lower Explosive Limit, which is the minimum concentration of a gas or vapor in air that will ignite if a source of ignition is present.
LEL is used to determine the potential for a fire or explosion in a confined space.
Procedures for LEL testing involve using gas detection equipment to measure the concentration of a specific gas in the air.
If the LEL of a gas is exceeded, it indicates a potentially hazard...
Control of confined spaces is essential for ensuring the safety of workers in potentially hazardous environments.
Implementing a permit-to-work system to control access to confined spaces
Conducting thorough risk assessments before entry
Providing appropriate training for workers on confined space entry procedures
Using gas detectors and ventilation systems to monitor and control atmospheric conditions
Having a rescue plan
I applied via Campus Placement and was interviewed before Aug 2022. There were 2 interview rounds.
posted on 15 Jul 2024
I applied via Approached by Company and was interviewed in Jun 2024. There was 1 interview round.
I applied via Naukri.com and was interviewed before May 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed in Sep 2020. There was 1 interview round.
HIRA stands for Hazard Identification and Risk Assessment. Hierarchy of Control Measures is a systematic approach to eliminate or minimize hazards.
HIRA is a process of identifying potential hazards and analyzing the associated risks.
Hierarchy of Control Measures is a step-by-step approach to eliminate or minimize hazards.
The hierarchy includes five levels: elimination, substitution, engineering controls, administrative...
Precautions must be taken to ensure safe lifting work.
Assess the weight of the load and ensure it is within the safe lifting limit.
Use proper lifting techniques, such as bending at the knees and keeping the back straight.
Wear appropriate personal protective equipment, such as gloves and safety shoes.
Ensure the lifting area is clear of obstacles and hazards.
Use mechanical aids, such as cranes or forklifts, for heavy loa...
I applied via Recruitment Consulltant and was interviewed in Mar 2021. There were 2 interview rounds.
There are several types of ducts and joints used in HVAC systems.
There are four main types of ducts: round, rectangular, oval, and flexible.
Duct joints can be classified as slip joints, drive connections, flanged joints, and snap-lock joints.
The type of duct and joint used depends on the specific HVAC system and its requirements.
Proper installation and sealing of ducts and joints is crucial for efficient and effective
The question is unclear. Please provide more context.
I applied via Company Website and was interviewed before Oct 2021. There were 2 interview rounds.
posted on 9 Oct 2020
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Safety Officer
10
salaries
| ₹5.4 L/yr - ₹15.5 L/yr |
HSE Officer
7
salaries
| ₹1 L/yr - ₹9.8 L/yr |
Senior Safety Officer
7
salaries
| ₹8 L/yr - ₹12 L/yr |
Electrical Engineer
6
salaries
| ₹3.5 L/yr - ₹12.2 L/yr |
Store Keeper
6
salaries
| ₹4.1 L/yr - ₹9 L/yr |
Saudi Binladin Group
Eversendai
Descon Engineering
Amara Raja Infra