Filter interviews by
I applied via Walk-in and was interviewed in May 2022. There were 2 interview rounds.
Top trending discussions
posted on 23 Jan 2025
I was interviewed in Dec 2024.
Maintenance procedures involve regular inspections, testing, and repairs to ensure equipment functionality and safety.
Regularly schedule maintenance tasks to prevent breakdowns and ensure equipment longevity
Conduct thorough inspections to identify potential issues before they escalate
Keep detailed records of maintenance activities and equipment history
Train staff on proper maintenance procedures and safety protocols
Uti...
To maintain a battery bank, regular inspections, proper charging, temperature control, and monitoring electrolyte levels are essential.
Perform regular inspections to check for signs of corrosion, leaks, or damage
Ensure proper charging by following manufacturer's guidelines and avoiding overcharging
Control temperature to prevent overheating or freezing, which can reduce battery life
Monitor electrolyte levels and top up ...
posted on 24 Jan 2024
I applied via Walk-in and was interviewed in Dec 2023. There was 1 interview round.
Earthing is the process of connecting electrical equipment or installations to the earth to prevent electric shock and protect against electrical faults.
Earthing involves creating a connection between the electrical system and the earth.
It is done by burying a metal conductor, such as a copper rod, in the ground.
The metal conductor is connected to the electrical system using a wire or cable.
Earthing provides a path for...
The type of DGs used at our site are diesel generators.
Diesel generators are commonly used as backup power sources in various industries.
They are reliable and can provide a continuous power supply during electrical outages.
DGs are often used in remote locations or areas with unreliable grid power.
They require regular maintenance and fuel supply to operate efficiently.
Examples of DGs used at our site include Cummins, Ca
LT line refers to Low Tension line while HT line refers to High Tension line.
LT line carries low voltage and is used for domestic and small-scale commercial purposes.
HT line carries high voltage and is used for industrial and large-scale commercial purposes.
LT line voltage is typically up to 440 volts, while HT line voltage is above 440 volts.
LT lines are usually overhead lines, while HT lines can be both overhead and ...
We used different types of circuit breakers at the site depending on the specific requirements.
We used air circuit breakers (ACBs) for low voltage applications.
For medium voltage applications, we used vacuum circuit breakers (VCBs) or oil circuit breakers (OCBs).
In high voltage installations, we used sulfur hexafluoride (SF6) circuit breakers.
For specialized applications like generator protection, we used differential ...
The size of transformers used at the site varied depending on the specific requirements of the project.
Transformers used at the site were of different sizes based on the power demand of the electrical system.
For smaller projects, transformers with a capacity of around 100 kVA were used.
For medium-sized projects, transformers with a capacity ranging from 250 kVA to 500 kVA were used.
For larger projects, transformers wit...
We used a stationary type batching plant at the site.
We used a stationary type batching plant for our construction project.
The stationary batching plant had a higher production capacity compared to mobile plants.
It was equipped with multiple storage bins for different types of aggregates.
The plant had a conveyor belt system to transfer the aggregates to the mixer.
We used this type of batching plant because it provided
Ohm's law states that the current flowing through a conductor between two points is directly proportional to the voltage across the two points.
Ohm's law is represented by the equation V = IR, where V is voltage, I is current, and R is resistance.
It is commonly used in electrical engineering to calculate the relationship between voltage, current, and resistance in a circuit.
For example, if a circuit has a voltage of 12V...
I applied via Campus Placement and was interviewed before May 2023. There was 1 interview round.
posted on 15 Feb 2024
I applied via Referral and was interviewed before Feb 2023. There was 1 interview round.
posted on 16 Apr 2022
I applied via Recruitment Consultant and was interviewed in Oct 2020. There was 1 interview round.
posted on 23 Nov 2020
I applied via Referral and was interviewed before Nov 2019. There were 3 interview rounds.
Civil Site Engineer
17
salaries
| ₹2.1 L/yr - ₹5.4 L/yr |
Project Manager
17
salaries
| ₹4.2 L/yr - ₹15.4 L/yr |
Project Engineer
15
salaries
| ₹4.2 L/yr - ₹8.4 L/yr |
Civil Foreman
12
salaries
| ₹3.2 L/yr - ₹5 L/yr |
Accountant
11
salaries
| ₹2.5 L/yr - ₹8.8 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
GMR Group