i
Jindal Saw
Filter interviews by
I applied via Company Website and was interviewed in Nov 2023. There were 2 interview rounds.
Top trending discussions
I applied via Naukri.com and was interviewed before Mar 2020. There was 1 interview round.
An overhead crane operator is responsible for operating and controlling overhead cranes to lift, move, and position heavy loads.
Operate and control overhead cranes
Lift, move, and position heavy loads
Ensure safety protocols are followed
Inspect and maintain equipment
Communicate with team members and follow instructions
posted on 24 Jan 2024
I applied via Company Website and was interviewed in Dec 2023. There was 1 interview round.
I applied via Approached by Company and was interviewed before Jun 2021. There was 1 interview round.
This question seems to be related to electrical or technical terminology.
The question may be asking about the status of a DSL (Digital Subscriber Line) connection being full from a LT (Local Terminal) connection being full.
It could be related to network or internet connectivity issues.
The question may be seeking troubleshooting steps or solutions for resolving the issue.
The question seems to be asking about the full capacity of an EOT crane.
EOT crane refers to Electric Overhead Traveling crane, which is used for lifting and moving heavy loads.
The 'c t full' likely refers to the full capacity of the crane, which is the maximum weight it can lift safely.
To determine the full capacity of an EOT crane, you need to consider factors like the type of crane, its design specifications, and any...
I applied via Company Website and was interviewed in Oct 2024. There were 4 interview rounds.
EOT crane stands for Electric Overhead Traveling crane, which is a type of crane used for lifting and moving heavy loads in industrial settings.
EOT crane is commonly used in factories, warehouses, and construction sites.
It is operated using electricity for lifting and moving heavy objects.
EOT cranes are equipped with a hoist, trolley, and bridge for efficient material handling.
Examples of EOT crane manufacturers includ
Light/hooter Runing time mobile phone not use
2prakar gravit/rotary
Digital Subscriber Line
DSL stands for Digital Subscriber Line
It is a type of technology that provides internet access through telephone lines
DSL allows for faster internet speeds compared to traditional dial-up connections
I applied via Naukri.com and was interviewed in Jan 2024. There was 1 interview round.
EOT stands for Electric Overhead Traveling crane, which is a type of crane used for lifting and moving heavy loads in industrial settings.
EOT stands for Electric Overhead Traveling crane
It is commonly used in industrial settings for lifting and moving heavy loads
EOT cranes are operated using electricity for smooth and efficient operation
Limit switches are safety devices used to prevent the crane from overtraveling or overloading.
Limit switches are installed on cranes to set boundaries for the crane's movement.
They are used to prevent the crane from overtraveling in any direction.
Limit switches can also be used to prevent overloading by stopping the crane when it reaches a certain weight limit.
Common types of limit switches include lever-operated, push
I appeared for an interview in Dec 2016.
I applied via Company Website and was interviewed in Jul 2018. There were 5 interview rounds.
Implemented a new customer feedback system resulting in increased customer satisfaction and retention rates.
Identified the need for a more efficient feedback system
Researched and implemented a new software to collect and analyze customer feedback
Analyzed the data to identify trends and areas for improvement
Implemented changes based on feedback leading to improved customer satisfaction and retention rates
I have a strong passion for leadership and a proven track record of motivating teams to achieve success.
Proven track record of successfully leading teams in previous roles
Passionate about developing and mentoring team members
Strong communication and interpersonal skills
Ability to problem-solve and make quick decisions under pressure
Composite error and ratio error are two types of errors in current transformers.
Composite error is the combination of ratio error and phase angle error in a current transformer.
Ratio error is the difference between the actual turns ratio and the specified turns ratio of a current transformer.
Phase angle error is the angular difference between the primary and secondary currents of a current transformer.
Composite error a...
An AC drive circuit diagram controls the speed of an AC motor by varying the frequency and voltage of the power supplied to it.
An AC drive consists of a rectifier, DC link, inverter, and control circuitry.
The rectifier converts AC power to DC power, which is stored in the DC link.
The inverter converts the DC power back to AC power with variable frequency and voltage.
The control circuitry adjusts the frequency and volta...
A single line diagram of a distribution system is required with proper specifications.
The diagram should show the flow of power from the source to the load
It should include all components such as transformers, switchgear, and cables
The specifications should include voltage levels, power ratings, and protection devices
The diagram should follow standard symbols and conventions
Example: A 11 kV distribution system with a 5
Dewpoint test is done in transformer to check the moisture content in the insulation oil.
Moisture in insulation oil can cause breakdown of transformer insulation
Dewpoint test helps to determine the moisture content in the oil
It is a preventive maintenance measure to avoid transformer failure
The test involves cooling a mirror until dew forms on it, and measuring the temperature at which dew forms
Power transformers are used in transmission systems to step up or down voltage, while distribution transformers are used in distribution systems to step down voltage.
Power transformers are used in high voltage transmission systems to step up or down voltage for long distance transmission.
Distribution transformers are used in low voltage distribution systems to step down voltage for local distribution.
Power transformers...
Buchholz relay is used to protect transformers from faults by detecting gas and oil flow abnormalities.
Buchholz relay is installed in the pipe connecting the transformer tank and conservator tank.
It operates based on the principle that faults in the transformer generate gases and cause oil flow disturbances.
When gas or oil flow abnormalities occur, the relay trips and sends a signal to the control panel to isolate the ...
based on 1 interview
Interview experience
Assistant Manager
391
salaries
| ₹4.4 L/yr - ₹13.9 L/yr |
Senior Executive
343
salaries
| ₹3 L/yr - ₹8.8 L/yr |
Deputy Manager
250
salaries
| ₹6.5 L/yr - ₹17 L/yr |
Senior Engineer
189
salaries
| ₹3 L/yr - ₹9 L/yr |
Manager
132
salaries
| ₹8.2 L/yr - ₹19.6 L/yr |
Tata Steel
JSW Steel
Jindal Steel and Power
ArcelorMittal Nippon Steel