RO plant stands for Reverse Osmosis plant. It is a water treatment system that uses a semi-permeable membrane to remove impurities from water.
RO plant is used to purify water by removing contaminants through the process of reverse osmosis.
It works by applying pressure to the water, forcing it through a membrane that only allows pure water molecules to pass through, leaving behind impurities.
RO plants are commonly used ...
RO membrane works by using pressure to separate water molecules from impurities.
RO membrane uses a semi-permeable membrane to remove dissolved solids, ions, and other contaminants from water.
Water is forced through the membrane under high pressure, allowing only water molecules to pass through while rejecting impurities.
The membrane has tiny pores that are smaller than most contaminants, allowing only water molecules t...
Top trending discussions
I applied via Referral and was interviewed before Aug 2021. There was 1 interview round.
I applied via Referral and was interviewed before Nov 2020. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Apr 2021. There were 2 interview rounds.
Group discussion
Coding test
Reality to my Electrician job and my family details
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
It is a measure of how efficiently electrical power is being used.
It ranges from 0 to 1, with 1 being the most efficient.
A low power factor can result in higher energy costs and equipment damage.
Capacitors can be used to improve power factor.
Example: A motor with a power factor of 0.8 requires 1.25 times more current than a motor with a power fa
I applied via Referral and was interviewed before Aug 2021. There were 2 interview rounds.
I appeared for an interview before Feb 2024.
The role of APFC (Automatic Power Factor Controller) is to maintain the power factor of electrical systems by automatically switching capacitors in and out of the circuit.
APFC monitors the power factor of the system and activates or deactivates capacitors accordingly.
It helps in reducing electricity bills by improving power factor and reducing reactive power consumption.
APFC ensures efficient utilization of electrical ...
Transformation ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding of a transformer.
Transformation ratio determines the voltage transformation between the primary and secondary windings of a transformer.
It is calculated as the ratio of the number of turns in the primary winding to the number of turns in the secondary winding.
For example, if a transformer has ...
based on 1 interview
Interview experience
Facility Executive
233
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Assistant Manager
126
salaries
| ₹3.8 L/yr - ₹10.1 L/yr |
Assistant Facility Manager
107
salaries
| ₹3.3 L/yr - ₹8 L/yr |
Technical Executive
80
salaries
| ₹3 L/yr - ₹5.2 L/yr |
Facility Manager
79
salaries
| ₹4.2 L/yr - ₹12 L/yr |
Sodexo
Compass Group Support Services
Leadec India
OCS Group