Composite error and ratio error are two types of errors in current transformers.
Composite error is the combination of ratio error and phase angle error in a current transformer.
Ratio error is the difference between the actual turns ratio and the specified turns ratio of a current transformer.
Phase angle error is the angular difference between the primary and secondary currents of a current transformer.
Composite error a...
An AC drive circuit diagram controls the speed of an AC motor by varying the frequency and voltage of the power supplied to it.
An AC drive consists of a rectifier, DC link, inverter, and control circuitry.
The rectifier converts AC power to DC power, which is stored in the DC link.
The inverter converts the DC power back to AC power with variable frequency and voltage.
The control circuitry adjusts the frequency and volta...
A single line diagram of a distribution system is required with proper specifications.
The diagram should show the flow of power from the source to the load
It should include all components such as transformers, switchgear, and cables
The specifications should include voltage levels, power ratings, and protection devices
The diagram should follow standard symbols and conventions
Example: A 11 kV distribution system with a 5
Dewpoint test is done in transformer to check the moisture content in the insulation oil.
Moisture in insulation oil can cause breakdown of transformer insulation
Dewpoint test helps to determine the moisture content in the oil
It is a preventive maintenance measure to avoid transformer failure
The test involves cooling a mirror until dew forms on it, and measuring the temperature at which dew forms
Power transformers are used in transmission systems to step up or down voltage, while distribution transformers are used in distribution systems to step down voltage.
Power transformers are used in high voltage transmission systems to step up or down voltage for long distance transmission.
Distribution transformers are used in low voltage distribution systems to step down voltage for local distribution.
Power transformers...
Buchholz relay is used to protect transformers from faults by detecting gas and oil flow abnormalities.
Buchholz relay is installed in the pipe connecting the transformer tank and conservator tank.
It operates based on the principle that faults in the transformer generate gases and cause oil flow disturbances.
When gas or oil flow abnormalities occur, the relay trips and sends a signal to the control panel to isolate the ...
I applied via Campus Placement and was interviewed before Sep 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Feb 2021. There were 4 interview rounds.
I applied via Naukri.com and was interviewed before Oct 2021. There were 2 interview rounds.
I applied via Company Website and was interviewed in Jul 2021. There were 3 interview rounds.
EOt crane is an electric overhead traveling crane used for lifting and moving heavy loads in industrial settings.
EOt stands for Electric Overhead Traveling
It is operated by an electrical control system
It consists of a bridge, hoist, trolley, and electrical components
It is commonly used in factories, warehouses, and construction sites
It can lift and move heavy loads up to several tons
It requires regular maintenance and
I applied via LinkedIn and was interviewed in Aug 2024. There was 1 interview round.
I applied via Naukri.com and was interviewed in Nov 2022. There were 2 interview rounds.
A thermocouple is a device that measures temperature by detecting the voltage difference between two different metals.
Consists of two different metal wires joined at one end
Produces a voltage that varies with temperature
Used in temperature measurement and control systems
Commonly used in industrial applications such as furnaces and boilers
The ohmic value of PT-100 is 100 ohms at 0°C.
PT-100 is a type of platinum resistance thermometer.
It has a resistance of 100 ohms at 0°C.
The resistance increases with temperature at a rate of 0.385 ohms/°C.
PT-100 is commonly used in industrial temperature measurement applications.
Calibration 3.0 and 5.0 refer to the accuracy level of a measuring instrument.
Calibration 3.0 means the instrument has an accuracy level of 0.3% of the full scale reading.
Calibration 5.0 means the instrument has an accuracy level of 0.5% of the full scale reading.
The higher the calibration number, the more accurate the instrument is.
Calibration is the process of adjusting an instrument to ensure its accuracy.
Calibratio...
I applied via Company Website and was interviewed before Jan 2022. There were 2 interview rounds.
I applied via Company Website and was interviewed in Feb 2022. There was 1 interview round.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Executive
81
salaries
| ₹2.4 L/yr - ₹6.5 L/yr |
Executive Engineer
78
salaries
| ₹3 L/yr - ₹6.5 L/yr |
Assistant Manager
25
salaries
| ₹5.1 L/yr - ₹10.7 L/yr |
Junior Supervisor
24
salaries
| ₹1.7 L/yr - ₹3.2 L/yr |
Production Engineer
20
salaries
| ₹3.5 L/yr - ₹6.1 L/yr |
Tata Steel
JSW Steel
Jindal Stainless
Jindal Saw