Meter testing as per IS standard involves verifying the accuracy and functionality of meters used for measuring electricity, water, gas, etc.
Meter testing should be conducted in accordance with the relevant IS standard (e.g. IS 13779 for electricity meters).
Testing involves checking the accuracy of the meter readings under various load conditions.
Calibration of the meter should be done periodically to ensure accurate m...
Distance relay configuration involves setting the relay to operate based on the distance of a fault from the relay location.
Distance relay settings include reach, time delay, and pickup values.
Testing involves injecting a fault at a known distance and verifying the relay operates within the set parameters.
Secondary injection testing can be used to simulate fault conditions for testing purposes.
Top trending discussions
posted on 2 Jun 2023
Aptitiude, Reasoning , EEE basic Questions
A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction.
Consists of two coils of wire, known as primary and secondary coils
Primary coil receives electrical energy and creates a magnetic field
Magnetic field induces a voltage in the secondary coil, transferring energy
Used in power distribution, voltage regulation, and electrical isolation
Exampl...
Mutual induction is the process where a changing current in one coil induces a voltage in another coil.
Mutual induction occurs when two coils are placed close to each other and the magnetic field produced by one coil induces a voltage in the other coil.
The induced voltage in the second coil is directly proportional to the rate of change of current in the first coil.
This phenomenon is the basis for the operation of tran...
Flux is the flow of electric or magnetic field lines through a surface, while current is the flow of electric charge.
Flux is a measure of the flow of a physical property through a given area.
In electromagnetism, flux refers to the flow of electric or magnetic field lines through a surface.
Current is the flow of electric charge through a conductor.
Flux and current are related through Faraday's law of electromagnetic ind
posted on 23 Jun 2023
I applied via Company Website and was interviewed before Jun 2022. There were 3 interview rounds.
DTR stands for Dead Time Recovery. It is a structure used in the oil and gas industry to separate gas and liquid phases.
DTR is typically made of steel or other corrosion-resistant materials.
The structure is designed to handle high pressure and temperature conditions.
Common materials used in the construction of DTR include carbon steel, stainless steel, and duplex stainless steel.
The choice of material depends on factor...
A Bucoz relay is a type of protective relay used in power systems to detect faults and isolate them to prevent damage.
Bucoz relay is a type of protective relay used in power systems.
It functions by detecting faults in the system and isolating them to prevent damage.
It helps in maintaining the stability and reliability of the power system.
Bucoz relay operates based on the principle of electromagnetic induction.
Examples ...
Pipe earthing of DTR involves using a metal pipe buried in the ground to provide a low-resistance path for fault currents.
Metal pipe is buried vertically in the ground near the DTR
The pipe is filled with alternate layers of charcoal and salt to improve conductivity
A copper wire is connected to the pipe and then to the DTR for grounding purposes
I appeared for an interview before Mar 2024, where I was asked the following questions.
I applied via Company Website and was interviewed in Feb 2022. There were 4 interview rounds.
Discuss work related questions
Distribution voltage refers to the voltage level at which electricity is distributed from substations to consumers.
Distribution voltage typically ranges from 4 kV to 33 kV for residential and commercial areas.
Higher distribution voltages, such as 66 kV or 132 kV, are used for industrial areas or large consumers.
The choice of distribution voltage depends on factors like distance, load requirements, and cost.
Transformers...
I applied via Referral and was interviewed before Nov 2023. There were 2 interview rounds.
based on 2 interviews
Interview experience
based on 8 reviews
Rating in categories
Assistant Manager
60
salaries
| ₹4.5 L/yr - ₹10.5 L/yr |
Executive
34
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Deputy Manager
33
salaries
| ₹5.6 L/yr - ₹13.9 L/yr |
Executive Engineer
19
salaries
| ₹3.2 L/yr - ₹7.2 L/yr |
Assistant General Manager
12
salaries
| ₹16 L/yr - ₹27 L/yr |
Suzlon Group
Tata Power
Dhoot Transmission
SAEL Industries Limited