Filter interviews by
I was interviewed in Dec 2019.
Motor coil condition can be checked by measuring the resistance and insulation resistance.
Measure the resistance of each coil using a multimeter.
Compare the measured resistance with the manufacturer's specifications.
Measure the insulation resistance between the coil and the motor frame using a megohmmeter.
Check for any signs of physical damage or wear on the coils.
Perform a visual inspection of the motor windings for a...
The procedure for spindle dismandle involves several steps to ensure safety and proper disassembly.
Disconnect power supply and lockout/tagout equipment
Remove any attachments or accessories from the spindle
Remove the spindle from the machine using appropriate tools
Disassemble the spindle by removing the retaining nut, bearings, and other components
Inspect all components for wear or damage and replace as necessary
Clean a...
To check lube oil flow in guideways, use flow meters or pressure gauges.
Install flow meters or pressure gauges in the lube oil system
Monitor the readings to ensure proper flow rate
Check for any abnormalities or fluctuations in the readings
Perform regular maintenance and cleaning of the flow meters or pressure gauges
Consult the manufacturer's guidelines for recommended flow rates and maintenance procedures
The procedure to change a drive involves several steps to ensure safety and proper installation.
Disconnect power supply to the drive
Remove the old drive and disconnect all cables
Install the new drive and connect all cables
Configure the new drive settings
Test the new drive to ensure proper operation
Spindle drive alarm is a warning system that indicates a problem with the spindle drive.
Alarm number 300 is related to spindle drive overload
Remedy for this alarm is to reduce the load on the spindle drive
Alarm number 301 is related to spindle drive overheat
Remedy for this alarm is to check the cooling system and reduce the load on the spindle drive
Alarm number 302 is related to spindle drive communication error
Remedy ...
Top trending discussions
posted on 27 Mar 2023
I applied via Recruitment Consulltant and was interviewed in Feb 2023. There were 4 interview rounds.
Maintenance is the process of ensuring that equipment, machinery, or facilities are in good working condition.
Regular inspection and repair of equipment
Preventive maintenance to avoid breakdowns
Corrective maintenance to fix issues
Predictive maintenance to anticipate problems
Maintenance scheduling and record-keeping
Training and development of maintenance staff
Continuous improvement of maintenance processes
Examples: oil ...
Maintenance has several benefits including increased equipment lifespan, improved safety, reduced downtime, and cost savings.
Increased equipment lifespan: Regular maintenance helps identify and address issues before they become major problems, extending the lifespan of equipment.
Improved safety: Maintenance ensures that equipment is functioning properly, reducing the risk of accidents and injuries.
Reduced downtime: Reg...
An aptitude test is an exam used to determine an individual's skill or propensity to succeed in a given activity.
Benefits of maintenance of electrical instrument
Current can be measured using an ammeter, which measures the flow of electric charge in a circuit.
Use an ammeter to measure current
Connect the ammeter in series with the circuit
Ensure the ammeter is set to the appropriate range for the expected current
Read the current value displayed on the ammeter
Example: To measure the current flowing through a light bulb, connect the ammeter in series with the bulb and read the disp
When encountering technical issues, it is important to follow a systematic approach to identify, troubleshoot, and resolve the problem.
Start by gathering information about the issue, such as error messages, symptoms, and any recent changes or events that may have triggered the problem.
Analyze the available data to narrow down the possible causes of the issue.
Use diagnostic tools and techniques to further investigate an...
MCB stands for Miniature Circuit Breaker. It is an electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit.
MCB is a type of circuit breaker that automatically switches off the electrical circuit when it detects an overload or short circuit.
It is commonly used in residential and commercial buildings to protect electrical appliances and wiring from damage.
MCBs are more ...
I applied via Campus Placement and was interviewed in Oct 2021. There were 3 interview rounds.
posted on 22 Aug 2017
I was interviewed in Apr 2017.
The hydraulic pack pressure varies depending on the specific system and application.
Hydraulic pack pressure is the force exerted by the hydraulic fluid in a hydraulic system.
It is typically measured in pounds per square inch (psi) or bar.
The pressure can vary based on the load requirements, system design, and component specifications.
Higher pressure is often required for heavy-duty applications, while lower pressure ma...
2 phase and 3 phase are different types of electrical power distribution systems.
2 phase system has two conductors and produces a single alternating current waveform.
3 phase system has three conductors and produces three alternating current waveforms.
2 phase system is less common and used in older applications.
3 phase system is more efficient and widely used in industrial and commercial settings.
2 phase system requires...
posted on 26 Feb 2024
I applied via LinkedIn and was interviewed in Jan 2024. There were 2 interview rounds.
Converter current flowing one direction in the circuit convert ac into dc is semiconductor devices, cycloconverter are easily used in 1 phase to 3 phase convert power also
A multimeter is a versatile tool used to measure voltage, current, and resistance in electrical circuits. Calibration ensures accuracy of measurements.
Multimeters are used to measure voltage, current, and resistance in electrical circuits
Calibration involves adjusting the multimeter to ensure accurate readings
Regular calibration is important to maintain the accuracy of the instrument
Examples of calibration methods incl...
To measure current device's other voltages and electromotive force, use a multimeter set to the appropriate range.
Set the multimeter to the voltage or electromotive force setting depending on what you want to measure.
Connect the multimeter leads to the appropriate terminals of the device being measured.
Read the measurement displayed on the multimeter.
Ensure the multimeter is set to the correct range to avoid damaging t...
posted on 9 Jul 2024
I applied via Recruitment Consulltant and was interviewed in Jan 2024. There were 3 interview rounds.
I was interviewed in Feb 2023.
The question is unclear and lacks context. Please provide more information.
posted on 10 Apr 2023
I applied via Walk-in
I applied via Link hr and was interviewed in Oct 2022. There were 2 interview rounds.
posted on 16 Feb 2022
based on 1 review
Rating in categories
Junior Engineer
22
salaries
| ₹2 L/yr - ₹3.8 L/yr |
Quality Inspector
11
salaries
| ₹1.8 L/yr - ₹2.5 L/yr |
Quality Engineer
11
salaries
| ₹2.7 L/yr - ₹4 L/yr |
Production Engineer
10
salaries
| ₹2.4 L/yr - ₹5 L/yr |
Senior Engineer
9
salaries
| ₹5 L/yr - ₹8 L/yr |
John Deere
KONE
Sigma Electric Manufacturing Corporation
Caterpillar Inc