A 3-phase 4 wire system is a type of electrical system commonly used for power distribution.
Consists of three conductors carrying alternating current at the same frequency, with a fourth neutral conductor
Provides a more balanced and efficient power distribution compared to single-phase systems
Commonly used in industrial and commercial applications for higher power requirements
Example: Used in large factories, office bu
A characteristic of digital signal is that it is discrete and represented by binary numbers.
Digital signals are represented by discrete values
Digital signals are represented by binary numbers (0s and 1s)
Digital signals are less susceptible to noise compared to analog signals
Norton representation is preferred when the load impedance is known and fixed.
Norton representation is preferred when the load impedance is known and fixed, as it simplifies calculations.
Thevenin representation is preferred when the load impedance is unknown or variable.
Norton equivalent circuits are easier to analyze in terms of current flow and power calculations.
Thevenin equivalent circuits are easier to analyze in
Diploma in electrical engineering
Top trending discussions
posted on 24 Apr 2021
I applied via Naukri.com and was interviewed before Apr 2020. There were 3 interview rounds.
posted on 15 Jan 2024
posted on 3 Apr 2021
I applied via Referral and was interviewed in Oct 2020. There were 5 interview rounds.
I applied via Campus Placement and was interviewed before Apr 2019. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed before Jun 2020. There was 1 interview round.
MCB components are typically made of materials such as copper, silver, thermoplastics, and ceramics.
Copper is commonly used for conducting electricity in MCBs.
Silver is sometimes used as a contact material for better conductivity.
Thermoplastics like polyamide are used for insulation and housing of MCB components.
Ceramics are used for arc chutes to extinguish the arc when the MCB trips.
Other materials like steel, brass,...
based on 2 interviews
2 Interview rounds
based on 6 reviews
Rating in categories
Engineer
108
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Senior Engineer
104
salaries
| ₹2.8 L/yr - ₹8.6 L/yr |
Service Engineer
54
salaries
| ₹1 L/yr - ₹5 L/yr |
Design Engineer
49
salaries
| ₹2 L/yr - ₹7.3 L/yr |
Production Engineer
42
salaries
| ₹1.9 L/yr - ₹6 L/yr |
Havells
CG Power and Industrial Solutions
KEI Industries
Finolex Cables