i
GRUNE DESIGNS
Filter interviews by
I applied via Naukri.com and was interviewed before Jul 2022. There were 4 interview rounds.
Load estimation of system method.
Transformers fault calculations
APFC sizing
System planing
HT ring main design
posted on 22 Dec 2024
The output voltage of an AAAC Rabbit conductor is typically around 600 volts.
The output voltage of an AAAC Rabbit conductor is usually around 600 volts.
The exact output voltage may vary depending on the specific application and conditions.
It is important to consult the manufacturer's specifications for accurate information.
My execution work plan involves setting clear goals, creating a timeline, assigning tasks, monitoring progress, and adjusting as needed.
Set clear goals and objectives for the project
Create a detailed timeline with milestones and deadlines
Assign tasks to team members based on their strengths and expertise
Regularly monitor progress and make adjustments as needed
Communicate effectively with team members and stakeholders
Ut...
posted on 18 Jan 2024
I applied via Naukri.com and was interviewed in Feb 2023. There were 2 interview rounds.
posted on 17 Jan 2021
I applied via Referral
posted on 15 Aug 2024
posted on 2 Nov 2022
I applied via Recruitment Consulltant
posted on 22 Dec 2024
The output voltage of an AAAC Rabbit conductor is typically around 600 volts.
The output voltage of an AAAC Rabbit conductor is usually around 600 volts.
The exact output voltage may vary depending on the specific application and conditions.
It is important to consult the manufacturer's specifications for accurate information.
My execution work plan involves setting clear goals, creating a timeline, assigning tasks, monitoring progress, and adjusting as needed.
Set clear goals and objectives for the project
Create a detailed timeline with milestones and deadlines
Assign tasks to team members based on their strengths and expertise
Regularly monitor progress and make adjustments as needed
Communicate effectively with team members and stakeholders
Ut...
posted on 18 Jan 2024
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Substations use various equipment for power distribution and control.
Transformers: Step up or step down voltage levels.
Circuit breakers: Protect the system from overloads and faults.
Switchgear: Control and isolate electrical circuits.
Busbars: Distribute power to different parts of the substation.
Relays: Monitor and protect the system from abnormalities.
Capacitors: Improve power factor and voltage stability.
Disconnect s...
CTs, PTs, LAs, and Transformers are electrical devices used in power systems for measurement, protection, and voltage transformation.
CTs (Current Transformers) are used to measure and transform high currents into manageable levels for instruments and relays.
PTs (Potential Transformers) are used to measure and transform high voltages into low voltages for instruments and relays.
LAs (Lightning Arresters) are used to prot...
Circuit breakers are safety devices that protect electrical circuits from damage caused by overload, short circuit, or ground fault.
Circuit breakers are used to prevent damage to electrical equipment and wiring.
They interrupt the flow of electricity when there is an overload, short circuit, or ground fault.
Circuit breakers are commonly used in homes, businesses, and industrial settings.
They come in different sizes and ...
The rating of copper and aluminium cables depends on their size, insulation, and intended use.
Copper cables have higher conductivity and are therefore rated higher than aluminium cables of the same size.
The rating of a cable also depends on its insulation material and thickness.
Cables used for high voltage transmission have higher ratings than those used for low voltage applications.
For example, a 10 AWG copper cable m...
Types of protection on Transformer side line side
Overcurrent protection
Differential protection
Restricted earth fault protection
Overvoltage protection
Under voltage protection
Different types of relays are used for protection system such as overcurrent, differential, distance, and directional relays.
Overcurrent relays are used to protect against overloads and short circuits.
Differential relays are used to protect transformers and generators from internal faults.
Distance relays are used to protect transmission lines from faults.
Directional relays are used to protect against faults in specific...
Electrical Design Engineer
10
salaries
| ₹4 L/yr - ₹7.1 L/yr |
Sustainability Consultant
5
salaries
| ₹2.8 L/yr - ₹3.5 L/yr |
Senior Design Engineer
4
salaries
| ₹9.5 L/yr - ₹11.5 L/yr |
Senior Engineer Mechanical
4
salaries
| ₹15 L/yr - ₹15.2 L/yr |
Electrical Draughtsman
4
salaries
| ₹2.7 L/yr - ₹4.8 L/yr |
Urban Ladder
Pepperfry
LivSpace
HomeLane