Q1. 2) what are tests performed for autoclave?
Tests performed for autoclave include biological indicator testing, temperature mapping, and pressure testing.
Biological indicator testing is done to ensure that the autoclave is effectively killing microorganisms.
Temperature mapping is performed to ensure that the autoclave is maintaining the required temperature throughout the sterilization process.
Pressure testing is conducted to verify that the autoclave is maintaining the necessary pressure for sterilization.
Other tests ...read more
Q2. 1) what are HVAC tests?
HVAC tests are tests conducted to ensure the proper functioning and efficiency of heating, ventilation, and air conditioning systems.
HVAC tests involve checking the temperature control and distribution systems.
Tests may include measuring airflow, checking for leaks, and inspecting ductwork.
Performance tests are conducted to assess the overall efficiency and effectiveness of the HVAC system.
Examples of HVAC tests include air balance testing, refrigerant charge verification, an...read more
Q3. 10) what are input logs and out put logs, where we use these?
Input and output logs are records of data entering and leaving a system. They are used for troubleshooting and auditing purposes.
Input logs record data that enters a system, such as user input or data from another system.
Output logs record data that leaves a system, such as responses to user requests or data sent to another system.
These logs are used for troubleshooting issues with the system, as well as for auditing and compliance purposes.
Examples of systems that use input ...read more
Q4. 3) what are tests performed for tunnel?
Tests performed for tunnel include connectivity, throughput, latency, and security.
Connectivity tests ensure that the tunnel is properly established and data can be transmitted.
Throughput tests measure the amount of data that can be transmitted through the tunnel in a given time period.
Latency tests measure the delay between data being sent and received through the tunnel.
Security tests ensure that the tunnel is secure and data cannot be intercepted or tampered with.
Examples ...read more
Q5. 8) what is the speed(rpm) ratio for tunnel?
The speed ratio for a tunnel depends on various factors such as the size and type of the tunnel.
The speed ratio for a tunnel can range from 10 to 100 rpm depending on the size and type of the tunnel.
The speed ratio is calculated by dividing the speed of the conveyor belt by the speed of the tunnel.
For example, if the conveyor belt is moving at a speed of 100 feet per minute and the tunnel is 10 feet long, the speed ratio would be 10 rpm.
The speed ratio is important for ensuri...read more
Q6. 9) Different types of Gamp categorisation and what are they?
GAMP categorisation refers to the different levels of software used in the pharmaceutical industry.
GAMP stands for Good Automated Manufacturing Practice
There are five categories of GAMP: Category 1, 2, 3, 4, and 5
Each category has different requirements for validation and documentation
Category 1 includes software that has no impact on product quality
Category 5 includes software that has a direct impact on product quality
Q7. 7) what is F°= value in autoclave?
F°= value in autoclave refers to the temperature at which sterilization is carried out.
F°= value is the temperature at which autoclave sterilizes the equipment.
It is usually set at 121°C for 15 minutes for most applications.
The F°= value ensures that all microorganisms are killed during the sterilization process.
It is important to monitor and validate the F°= value to ensure proper sterilization.
Different F°= values may be required for different types of equipment or material...read more
Q8. 6) Define span, spread and equilibrium time?
Explanation of span, spread and equilibrium time.
Span refers to the duration of time over which a process or event occurs.
Spread refers to the distribution of values or results within a given set of data.
Equilibrium time is the time required for a system to reach a steady state or balance.
For example, the span of a clinical trial may be several years, the spread of test results may vary widely, and the equilibrium time for a chemical reaction may be minutes or hours.
Q9. 5) Flow of automation (CSV validation)?
Automation flow for CSV validation involves identifying data sources, creating test cases, executing tests, and generating reports.
Identify data sources and ensure data integrity
Create test cases based on requirements and expected outcomes
Execute tests using automation tools and scripts
Validate results and identify any discrepancies
Generate reports to document test results and findings
Q10. 4) Flow of equipment Qualifications?
Equipment qualifications follow a defined flow to ensure compliance with regulations and standards.
The first step is to define the equipment and its intended use.
Next, the equipment is installed and tested to ensure it meets specifications.
Operational qualifications are then performed to ensure the equipment functions correctly.
Performance qualifications are conducted to ensure the equipment consistently produces accurate and reliable results.
Finally, maintenance and calibrat...read more