Filter interviews by
I applied via Recruitment Consultant and was interviewed in Nov 2020. There were 3 interview rounds.
There are three types of multimeters: analog, digital, and clamp.
Analog multimeters use a needle to display readings.
Digital multimeters display readings on a digital screen.
Clamp multimeters measure current by clamping around a wire.
Examples of multimeter brands include Fluke, Klein Tools, and Extech.
LV cables typically have a voltage rating of 600V or less in construction use.
LV cables are used for low voltage applications in construction.
The voltage rating of LV cables is typically 600V or less.
LV cables are commonly used for power distribution, lighting, and control circuits.
Examples of LV cables include THHN, XHHW, and MC cables.
Yellow lights are used in the field for safety and warning purposes.
Yellow lights are used to indicate caution or warning in the field.
They are often used in construction sites, road work, and other hazardous areas.
Yellow lights can also be used to signal the presence of heavy machinery or equipment.
They are an important safety measure to prevent accidents and injuries.
Yellow lights are easily visible and catch the att
AC voltage is alternating current that changes direction periodically, while DC voltage is direct current that flows in one direction only.
AC voltage changes direction periodically, while DC voltage flows in one direction only
AC voltage is used in household appliances, while DC voltage is used in electronic devices
AC voltage is measured in volts RMS, while DC voltage is measured in volts
Examples of AC voltage sources i...
Star connection is used in motors to reduce the starting current and increase the torque.
Star connection reduces the voltage applied to each winding, resulting in lower starting current.
It also increases the torque produced by the motor.
Star connection is commonly used in motors with high starting current, such as induction motors.
It is also used in motors that require a high starting torque, such as compressors and pu
There are several types of cables used in construction, including power cables, control cables, communication cables, and more.
Power cables are used to transmit electrical power, such as high voltage cables for transmission lines and low voltage cables for distribution networks.
Control cables are used to transmit signals for controlling machinery and equipment, such as motor control cables and instrumentation cables.
Co...
CT stands for Current Transformer and CPT stands for Capacitor Potential Transformer.
CT is used to measure the current flowing in a circuit and step down the current to a level that can be measured by instruments.
CPT is used to measure the voltage of a circuit and step down the voltage to a level that can be measured by instruments.
Both CT and CPT are types of transformers used in electrical systems.
CT and CPT are comm...
Top trending discussions
I applied via Instahyre and was interviewed before May 2023. There were 2 interview rounds.
The speed difference between stator's rotating magnetic field and rotor's rmf is called slip.
The slip is necessary for inducing current in the rotor and producing torque.
The slip is typically around 1-3% in most induction motors.
Higher slip values can indicate issues with the motor such as overload or mechanical problems.
An induction motor is a type of AC motor where power is supplied to the rotor by electromagnetic induction.
Induction motors are commonly used in various applications such as industrial machinery, pumps, fans, and compressors.
They do not require brushes to transfer power to the rotor, making them more reliable and maintenance-free compared to brushed DC motors.
The speed of an induction motor is determined by the frequen...
Synchronisation is the process of coordinating multiple systems or devices to work together in harmony.
Synchronisation ensures that different components or processes are aligned in time.
It is commonly used in electrical systems to ensure that multiple generators are running in phase with each other.
In data communication, synchronisation is important for ensuring that data is transmitted and received at the correct timi...
The speed of a rotor with respect to the stator magnetic field in an induction motor is known as slip speed.
The slip speed is the difference between the synchronous speed of the rotating magnetic field in the stator and the actual speed of the rotor.
It is necessary for the rotor to operate at a speed slightly slower than the synchronous speed in order to induce current and generate torque.
The slip speed allows the roto...
Slip is the difference between synchronous speed and actual rotor speed in an induction motor. Per unit slip is the slip expressed as a fraction of synchronous speed.
Slip is the difference between synchronous speed (speed of the rotating magnetic field) and the actual rotor speed in an induction motor.
Per unit slip is the slip expressed as a fraction of synchronous speed, typically denoted as a percentage.
For example, ...
I appeared for an interview before Apr 2024, where I was asked the following questions.
I applied via Company Website and was interviewed before Aug 2020. There were 3 interview rounds.
I applied via Company Website and was interviewed in Apr 2023. There were 2 interview rounds.
Ohm's law states that the current through a conductor between two points is directly proportional to the voltage across the two points.
Ohm's law is represented by the equation I = V/R, where I is the current, V is the voltage, and R is the resistance.
It is named after Georg Simon Ohm, a German physicist who first formulated this law.
This law is applicable to all types of circuits, including DC and AC circuits.
It is use...
I appeared for an interview in Mar 2025, where I was asked the following questions.
Single phase and three phase are two types of electrical power distribution systems.
Single phase has one live conductor and one neutral conductor, while three phase has three live conductors and one neutral conductor.
Single phase is commonly used in residential and small commercial applications, while three phase is used in industrial and large commercial applications.
Single phase power supply is suitable for low power...
R, Y, B phases are the three phases of AC power supply. They differ in their phase angle and voltage level.
R phase has a phase angle of 0 degrees and is usually connected to the red wire.
Y phase has a phase angle of 120 degrees and is usually connected to the yellow wire.
B phase has a phase angle of 240 degrees and is usually connected to the blue wire.
The voltage level of each phase is the same, but they are out of ph...
In series, voltage adds up while current remains the same. In parallel, voltage remains the same while current adds up.
In series, batteries are connected end-to-end, positive to negative. In parallel, batteries are connected positive to positive and negative to negative.
Series connection increases voltage but does not increase current. Parallel connection increases current but does not increase voltage.
Series connectio...
Periodic maintenance of batteries is crucial for their longevity and optimal performance.
Check the battery terminals for corrosion and clean them if necessary
Inspect the battery case for any cracks or damage
Ensure that the battery is securely fastened in place
Check the electrolyte level and top up with distilled water if required
Test the battery voltage and recharge if necessary
A faulty battery can be identified by checking its voltage, capacity, and physical appearance.
Check the voltage of the battery using a multimeter
Test the capacity of the battery using a battery tester
Inspect the physical appearance of the battery for any signs of damage or leakage
Check the battery terminals for corrosion or loose connections
Compare the battery's performance to its specifications
FUSE, MCB, ELCB, and RCCB are all electrical protection devices, but they differ in their functions and applications.
FUSE is a simple device that protects electrical circuits from overloading or short-circuiting by melting and breaking the circuit.
MCB (Miniature Circuit Breaker) is an automatic switch that trips and cuts off the power supply when there is an overload or short-circuit.
ELCB (Earth Leakage Circuit Breaker...
A DOL starter is a direct online motor starter that provides full voltage to the motor.
Consists of a contactor, overload relay, and start/stop buttons
The contactor connects the motor to the power supply
The overload relay protects the motor from overloading
The start/stop buttons control the on/off function of the motor
Used for small motors with low starting current
Not suitable for large motors or motors with high starti
I applied via Naukri.com and was interviewed in Jan 2021. There was 1 interview round.
posted on 30 Apr 2021
Lighting levels for indoor and outdoor areas are determined based on the purpose of the space and the activities that take place.
Indoor lighting levels are typically measured in foot-candles or lux
Outdoor lighting levels are typically measured in lumens per square meter
Calculation procedures involve determining the required illuminance level for the space and selecting appropriate light fixtures and bulbs
Factors such a...
Cable glands are used to secure and seal cables in various applications based on the area of installation.
Cable glands are used in hazardous areas to prevent the entry of flammable gases and liquids.
In outdoor applications, cable glands are used to protect cables from moisture and dust.
In industrial settings, cable glands are used to secure cables and prevent them from being pulled out.
Different types of cable glands a...
based on 5 reviews
Rating in categories
HSE Officer
37
salaries
| ₹6 L/yr - ₹16 L/yr |
Safety Officer
15
salaries
| ₹4.3 L/yr - ₹15 L/yr |
Instrumentation Technician
13
salaries
| ₹3 L/yr - ₹10.6 L/yr |
Electrician
10
salaries
| ₹3 L/yr - ₹7 L/yr |
Piping Foreman
10
salaries
| ₹6.1 L/yr - ₹15 L/yr |
L&T Construction
Saint-Gobain
Worley
AECOM