i
Centrient
Pharmaceuticals
Filter interviews by
Woking process SOP is a set of instructions that outlines the steps to be followed for safe and efficient operation of the Woking process.
Woking process SOP includes safety procedures, equipment operation guidelines, and troubleshooting steps.
It ensures that the process is carried out consistently and efficiently.
Examples of Woking process SOPs include those for chemical manufacturing, food processing, and wastewa...
Our company uses a shell and tube condenser.
The condenser is designed to transfer heat from the steam to the cooling water.
It consists of a bundle of tubes through which the steam flows and a shell surrounding the tubes through which the cooling water flows.
The shell and tube condenser is commonly used in power plants and industrial processes.
Our company's condenser is made of stainless steel for durability and co...
The chiller gas leak test method involves pressurizing the chiller system with a gas and using a detector to identify any leaks.
Pressurize the chiller system with a gas, such as nitrogen or helium.
Use a gas detector to identify any leaks in the system.
Inspect all connections, valves, and fittings for potential leaks.
Perform a bubble test by applying a soapy solution to suspected leak areas and look for bubbles.
Uti...
The same problem in a machine that occurs repeatedly.
One common problem is overheating due to insufficient cooling.
Another common problem is a faulty sensor causing inaccurate readings.
A recurring issue could be a clogged filter leading to reduced efficiency.
Frequent breakdowns may be caused by worn-out or damaged components.
Inconsistent power supply can also be a recurring problem in machines.
TR Chiller machine is a type of chiller used for cooling applications in various industries.
TR Chiller machine is a refrigeration system that removes heat from a process or space.
It uses a compressor, condenser, expansion valve, and evaporator to cool the fluid or air.
TR stands for Ton of Refrigeration, which is a unit of cooling capacity.
TR Chiller machines are commonly used in HVAC systems, industrial processes,...
High pressure problem in chiller compressor
High pressure in chiller compressor can be caused by various factors such as dirty condenser coils, refrigerant leaks, or a malfunctioning expansion valve.
Excessive high pressure can lead to compressor overheating, reduced cooling capacity, and potential damage to the chiller system.
Regular maintenance and monitoring of the chiller system can help identify and resolve hig...
D.G. A, B, C, D checks refer to the operational checks for diesel generators in utility operations.
A: Check the fuel level to ensure adequate supply for operation.
B: Check the battery condition to ensure reliable starting.
C: Check the coolant level to prevent overheating during operation.
D: Check the oil level and quality to ensure proper lubrication.
Cooling towers are classified into two types: open circuit and closed circuit.
Open circuit cooling towers: Water is exposed to the atmosphere and cooled through evaporation.
Closed circuit cooling towers: Water is cooled indirectly through a heat exchanger.
Examples of cooling towers: Crossflow cooling tower, counterflow cooling tower, induced draft cooling tower, forced draft cooling tower.
A cooling tower problem refers to an issue or malfunction in the cooling system of a facility, which can lead to inefficient cooling or equipment failure.
Cooling tower problems can include issues with water quality, such as scaling or fouling, which can reduce heat transfer efficiency.
Mechanical problems like pump failures or fan malfunctions can also cause cooling tower problems.
Inadequate maintenance or improper...
Service time refers to the duration of time a machine is in operation.
Service time is measured in hours or minutes depending on the machine.
It is important to keep track of service time to ensure proper maintenance and avoid breakdowns.
Regular maintenance can increase service time and prolong the life of the machine.
For example, a generator may have a service time of 500 hours before it needs an oil change.
Monitor...
TR Chiller machine is a type of chiller used for cooling applications in various industries.
TR Chiller machine is a refrigeration system that removes heat from a process or space.
It uses a compressor, condenser, expansion valve, and evaporator to cool the fluid or air.
TR stands for Ton of Refrigeration, which is a unit of cooling capacity.
TR Chiller machines are commonly used in HVAC systems, industrial processes, and ...
Cooling towers are classified into two types: open circuit and closed circuit.
Open circuit cooling towers: Water is exposed to the atmosphere and cooled through evaporation.
Closed circuit cooling towers: Water is cooled indirectly through a heat exchanger.
Examples of cooling towers: Crossflow cooling tower, counterflow cooling tower, induced draft cooling tower, forced draft cooling tower.
Priming in pump is the process of removing air from the pump and filling it with liquid to create suction and start the pumping action.
Priming is necessary to ensure the pump is filled with liquid and there is no air trapped inside.
It involves filling the pump casing and suction pipe with liquid before starting the pump.
Priming can be done manually or automatically depending on the type of pump.
Examples of priming meth...
Service time refers to the duration of time a machine is in operation.
Service time is measured in hours or minutes depending on the machine.
It is important to keep track of service time to ensure proper maintenance and avoid breakdowns.
Regular maintenance can increase service time and prolong the life of the machine.
For example, a generator may have a service time of 500 hours before it needs an oil change.
Monitoring s...
D.G. A, B, C, D checks refer to the operational checks for diesel generators in utility operations.
A: Check the fuel level to ensure adequate supply for operation.
B: Check the battery condition to ensure reliable starting.
C: Check the coolant level to prevent overheating during operation.
D: Check the oil level and quality to ensure proper lubrication.
A cooling tower problem refers to an issue or malfunction in the cooling system of a facility, which can lead to inefficient cooling or equipment failure.
Cooling tower problems can include issues with water quality, such as scaling or fouling, which can reduce heat transfer efficiency.
Mechanical problems like pump failures or fan malfunctions can also cause cooling tower problems.
Inadequate maintenance or improper oper...
The chiller gas leak test method involves pressurizing the chiller system with a gas and using a detector to identify any leaks.
Pressurize the chiller system with a gas, such as nitrogen or helium.
Use a gas detector to identify any leaks in the system.
Inspect all connections, valves, and fittings for potential leaks.
Perform a bubble test by applying a soapy solution to suspected leak areas and look for bubbles.
Utilize ...
I am seeking new challenges and opportunities for growth that align with my career goals and aspirations.
Desire for career advancement: I feel that I have reached a plateau in my current role and am looking for opportunities to grow.
Seeking new challenges: I want to work in an environment that pushes me to develop new skills and take on more responsibilities.
Alignment with long-term goals: My career aspirations have ev...
The same problem in a machine that occurs repeatedly.
One common problem is overheating due to insufficient cooling.
Another common problem is a faulty sensor causing inaccurate readings.
A recurring issue could be a clogged filter leading to reduced efficiency.
Frequent breakdowns may be caused by worn-out or damaged components.
Inconsistent power supply can also be a recurring problem in machines.
High pressure problem in chiller compressor
High pressure in chiller compressor can be caused by various factors such as dirty condenser coils, refrigerant leaks, or a malfunctioning expansion valve.
Excessive high pressure can lead to compressor overheating, reduced cooling capacity, and potential damage to the chiller system.
Regular maintenance and monitoring of the chiller system can help identify and resolve high pre...
Woking process SOP is a set of instructions that outlines the steps to be followed for safe and efficient operation of the Woking process.
Woking process SOP includes safety procedures, equipment operation guidelines, and troubleshooting steps.
It ensures that the process is carried out consistently and efficiently.
Examples of Woking process SOPs include those for chemical manufacturing, food processing, and wastewater t...
Our company uses a shell and tube condenser.
The condenser is designed to transfer heat from the steam to the cooling water.
It consists of a bundle of tubes through which the steam flows and a shell surrounding the tubes through which the cooling water flows.
The shell and tube condenser is commonly used in power plants and industrial processes.
Our company's condenser is made of stainless steel for durability and corrosi...
Top trending discussions
posted on 17 Jan 2025
I applied via Referral and was interviewed in Dec 2024. There were 3 interview rounds.
Our organization is a leading retail company specializing in high-quality fashion and accessories.
Founded in 2005 by a group of fashion enthusiasts
Over 100 stores nationwide
Focus on sustainable and ethical sourcing practices
Collaborations with renowned designers like Stella McCartney
Strong online presence with e-commerce platform
I am available to start immediately.
I can start as soon as possible.
I am flexible with my start date.
I am ready to join the team whenever needed.
posted on 25 Oct 2024
I applied via Referral and was interviewed in Apr 2024. There was 1 interview round.
I applied via Referral and was interviewed before Dec 2023. There was 1 interview round.
I am a dedicated professional with 5 years of experience in management roles, specializing in team leadership and project coordination.
5 years of experience in management roles
Specialize in team leadership and project coordination
I applied via Walk-in and was interviewed in Nov 2024. There were 2 interview rounds.
Related to pharma industry including sales and marketing
I applied via Campus Placement and was interviewed in Jul 2024. There was 1 interview round.
Nice aptitude questions of logical reasons and data interpretation
I appeared for an interview before Apr 2024, where I was asked the following questions.
Yes, I am familiar with Adobe Analytics and have experience using it for data analysis.
I have used Adobe Analytics to track website traffic and user behavior
I have created custom reports and dashboards using Adobe Analytics
I am proficient in extracting insights from Adobe Analytics data to drive business decisions
based on 1 review
Rating in categories
Senior Executive
38
salaries
| ₹5.4 L/yr - ₹11 L/yr |
Executive
36
salaries
| ₹3.7 L/yr - ₹7.8 L/yr |
Officer
35
salaries
| ₹3.5 L/yr - ₹5.8 L/yr |
Assistant Manager
28
salaries
| ₹10.1 L/yr - ₹16.6 L/yr |
Supervisor
18
salaries
| ₹2.7 L/yr - ₹4 L/yr |
Apotex Research
Apitoria Pharma
Encube Ethicals
Raptakos Brett and Company