i
Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Sep 2023. There was 1 interview round.
The least count of a Vernier caliper is the smallest measurement that can be read on the scale.
The least count of a Vernier caliper is typically 0.02 mm or 0.001 inches.
It is determined by the number of divisions on the main scale and the Vernier scale.
For example, if the main scale has 20 divisions and the Vernier scale has 10 divisions, the least count would be 0.02 mm.
Top trending discussions
I applied via Approached by Company and was interviewed in Aug 2023. There was 1 interview round.
RBI stands for Risk-Based Inspection, a method used to optimize inspection schedules based on risk levels.
RBI is a methodology used to determine the most effective inspection plan based on the risk associated with each piece of equipment or component.
It involves assessing the likelihood of failure and the consequences of failure to prioritize inspection efforts.
RBI helps in optimizing inspection intervals, reducing dow...
Hot tap is a method used to create a connection to a pressurized system without shutting it down.
Hot tap involves drilling into a pressurized system to create a branch connection.
It is commonly used in pipelines to install new equipment or perform maintenance without interrupting the flow.
Specialized equipment and procedures are used to ensure safety and integrity of the system during hot tapping.
Examples include addin...
Inspection procedure for pressure vessel involves visual inspection, non-destructive testing, and documentation review.
Visual inspection of the exterior and interior surfaces of the pressure vessel
Non-destructive testing methods such as ultrasonic testing, radiography, and magnetic particle testing
Review of documentation including design specifications, fabrication records, and previous inspection reports
Various types of NDT methods are used including ultrasonic testing, radiographic testing, magnetic particle testing, liquid penetrant testing, and visual testing.
Ultrasonic testing is used to detect internal flaws in materials by sending high-frequency sound waves through the material.
Radiographic testing uses X-rays or gamma rays to inspect the internal structure of a component.
Magnetic particle testing is used to det...
Interview experience
based on 2 reviews
Rating in categories
Quality Inspector
15
salaries
| ₹2 L/yr - ₹2.8 L/yr |
Quality Supervisor
5
salaries
| ₹2.1 L/yr - ₹3 L/yr |
Project Lead
4
salaries
| ₹4.2 L/yr - ₹6 L/yr |
Quality Engineer
4
salaries
| ₹2.2 L/yr - ₹4.2 L/yr |
Team Lead
4
salaries
| ₹3.5 L/yr - ₹4.2 L/yr |
TCS
Wipro
Infosys
Tech Mahindra