There are two main types of air conditioners: window units and central units.
Window units are self-contained and installed in a window or through a hole in an exterior wall.
Central units are larger and cool the entire house through a system of ducts.
Other types include portable units, split systems, and ductless mini-splits.
Air conditioners can also be categorized by their energy efficiency rating (EER) or seasonal ene
Top trending discussions
I applied via Naukri.com and was interviewed before May 2022. There were 4 interview rounds.
Technician questions on lab instruments like as pH meter, ir, uv, kf, hplc, titration and autotitrator etc
I was interviewed in Aug 2017.
Calibration is the process of adjusting or verifying the accuracy of a measuring instrument or device.
Calibration ensures that measurements taken by an instrument are accurate and reliable.
It involves comparing the measurements of a device to a known standard.
Calibration may involve adjusting the device to bring it in line with the standard.
It is important in various fields like engineering, manufacturing, and scientif...
Calibrating temperature indicators involves adjusting them to ensure accurate readings.
Calibration of temperature indicators involves comparing their readings to a known standard.
Adjustments are made to the indicators to align their readings with the standard.
Calibration may involve adjusting the zero point and span of the indicators.
Examples of temperature indicators include thermometers, temperature sensors, and temp
Calibration of RTDs involves comparing the sensor's output to a known reference and adjusting it accordingly.
RTDs (Resistance Temperature Detectors) are calibrated to ensure accurate temperature measurements.
Calibration involves comparing the RTD's resistance values at different temperatures to a known reference.
Adjustments are made to the RTD's output signal to align it with the reference values.
Calibration can be don...
There are several types of flow meters used in various industries to measure the flow rate of fluids or gases.
Some common types of flow meters include electromagnetic flow meters, ultrasonic flow meters, turbine flow meters, and positive displacement flow meters.
Electromagnetic flow meters use Faraday's law of electromagnetic induction to measure the flow rate of conductive fluids.
Ultrasonic flow meters utilize ultraso...
To check door interlock systems, inspect the physical components, test the electrical connections, and verify proper functioning.
Inspect the door hinges, latches, and locks for any damage or misalignment.
Check the wiring connections and ensure they are secure and not damaged.
Test the interlock switch by opening and closing the door to see if it activates properly.
Verify that the interlock system prevents the door from ...
To calibrate pressure gauges, vacuum gauges, and compound gauges, follow these steps:
Use a known reference pressure source to compare the readings of the gauges.
Adjust the gauges if there is any deviation from the reference pressure.
Repeat the process multiple times to ensure accuracy.
Document the calibration process and results for future reference.
Perform regular calibrations to maintain accuracy.
Example: For pressur...
based on 2 reviews
Rating in categories
Officer
123
salaries
| ₹2 L/yr - ₹3.7 L/yr |
Territory Business Manager
103
salaries
| ₹2.4 L/yr - ₹7 L/yr |
Key Account Manager
65
salaries
| ₹3.2 L/yr - ₹6.6 L/yr |
Senior Officer
63
salaries
| ₹2.5 L/yr - ₹5.7 L/yr |
Regional Business Manager
60
salaries
| ₹5.5 L/yr - ₹11.8 L/yr |
Serum Institute of India
Panacea Biotec
Biocon Limited
Zydus Lifesciences