Q1. 1. 12 mm Steel Rod using for construction ok that lapping length how much

Ans.

The lapping length for a 12 mm steel rod used in construction is typically 60 times the diameter of the rod.

  • Lapping length is usually 60 times the diameter of the steel rod

  • For a 12 mm steel rod, the lapping length would be 12 mm x 60 = 720 mm

  • Lapping is done to ensure continuity and strength in the reinforcement

View 1 answer

Q2. One concrete floor for broken so rectify the floor what kind of material using

Ans.

To rectify a broken concrete floor, materials like concrete mix, epoxy resin, or self-leveling compound can be used.

  • Use concrete mix to fill in the broken areas and level the floor.

  • Apply epoxy resin to seal cracks and strengthen the floor.

  • Consider using self-leveling compound for a smooth and even surface.

  • Ensure proper preparation and cleaning of the floor before applying any material.

  • Consult with a structural engineer if the damage is extensive or structural.

Add your answer

Q3. What is excavation ?

Ans.

Excavation is the process of removing earth or other materials from a site to create a hole or cavity.

  • Excavation is commonly done for construction purposes, such as building foundations or underground utilities.

  • It involves the use of heavy machinery, such as excavators or backhoes, to dig and remove the soil or rock.

  • Excavation may also be done for archaeological purposes to uncover artifacts or historical remains.

  • Safety measures, such as shoring or sloping, are often implemen...read more

View 8 more answers

Q4. 10 year gulf experience

Ans.

Yes, I have 10 years of experience working as an electrician in the Gulf region.

  • During my time in the Gulf, I gained extensive knowledge and experience in electrical systems and equipment commonly used in the region.

  • I have worked on various projects ranging from residential to commercial and industrial buildings.

  • I am familiar with the safety regulations and standards in the Gulf region and have always ensured that my work adheres to them.

  • I have also worked with a diverse team...read more

Add your answer
Discover Fine Digital interview dos and don'ts from real experiences

Q5. What type of footting using the oman country

Ans.

In Oman, commonly used footings include spread footings, strip footings, and raft footings.

  • Spread footings are used for individual columns or walls and distribute the load over a larger area.

  • Strip footings are continuous footings that support a line of columns or walls.

  • Raft footings are used for large or irregularly shaped structures to distribute the load over a wider area.

  • In Oman, due to the sandy soil conditions, deep foundations like piles may also be used for certain pro...read more

View 1 answer

Q6. What is cretical lifting ?

Ans.

Critical lifting refers to the process of lifting heavy objects or loads that require special attention and precautions to ensure safety.

  • Critical lifting involves assessing the weight and dimensions of the load to determine the appropriate lifting equipment and techniques.

  • It requires proper planning and coordination to minimize the risk of accidents and injuries.

  • Factors such as the stability of the load, the condition of the lifting equipment, and the competency of the person...read more

View 1 answer
Are these interview questions helpful?

Q7. What is the superheat , how to calculate superheat

Ans.

Superheat is the temperature increase of a vapor above its boiling point at a given pressure.

  • Superheat is important in HVAC systems to ensure proper refrigerant flow and system efficiency.

  • It is calculated by subtracting the boiling point temperature of the refrigerant at a given pressure from the actual temperature of the refrigerant.

  • The ideal superheat value varies depending on the type of refrigerant and the specific system, but typically falls between 5-20 degrees Fahrenhe...read more

Add your answer

Q8. Concrete setting times how many days

Ans.

Concrete setting times can vary depending on factors like temperature and mix design.

  • Concrete typically sets within 24-48 hours, but continues to harden over time.

  • Factors affecting setting time include temperature, humidity, and mix design.

  • For example, in hot weather, concrete may set faster, while in cold weather it may take longer.

  • Accelerators or retarders can be added to the mix to adjust setting times as needed.

Add your answer
Share interview questions and help millions of jobseekers 🌟

Q9. What is sup cooling What is function of expension value

Ans.

Subcooling is the process of cooling a liquid refrigerant below its saturation temperature.

  • Subcooling is achieved by removing heat from the refrigerant after it has been condensed.

  • It ensures that the refrigerant is in a liquid state before it enters the expansion valve.

  • The expansion valve reduces the pressure of the refrigerant and controls the flow rate into the evaporator.

  • This causes the refrigerant to evaporate and absorb heat from the surrounding air or water.

  • The expansio...read more

Add your answer

Q10. What is JHA

Ans.

JHA stands for Job Hazard Analysis. It is a systematic process used to identify and evaluate potential hazards in the workplace.

  • JHA is used to assess the risks associated with specific job tasks or activities.

  • It involves breaking down the job into steps, identifying potential hazards, and determining control measures to mitigate those hazards.

  • JHA helps in preventing accidents, injuries, and illnesses by proactively addressing workplace hazards.

  • Examples of hazards that may be ...read more

View 1 answer

Q11. Why are increased head pressure

Ans.

Increased head pressure in HVAC systems can be caused by various factors.

  • Dirty condenser coils

  • Blocked or restricted airflow

  • Refrigerant overcharge

  • Malfunctioning expansion valve

  • Faulty compressor

  • Ambient temperature increase

  • Clogged filter drier

  • Low refrigerant charge

  • Kinked or blocked refrigerant lines

Add your answer

Q12. Haw to maintain a battery bank

Ans.

To maintain a battery bank, regular inspections, proper charging, temperature control, and monitoring electrolyte levels are essential.

  • Perform regular inspections to check for signs of corrosion, leaks, or damage

  • Ensure proper charging by following manufacturer's guidelines and avoiding overcharging

  • Control temperature to prevent overheating or freezing, which can reduce battery life

  • Monitor electrolyte levels and top up with distilled water as needed to maintain proper levels

  • Im...read more

Add your answer

Q13. Procedure about maintenance

Ans.

Maintenance procedures involve regular inspections, testing, and repairs to ensure equipment functionality and safety.

  • Regularly schedule maintenance tasks to prevent breakdowns and ensure equipment longevity

  • Conduct thorough inspections to identify potential issues before they escalate

  • Keep detailed records of maintenance activities and equipment history

  • Train staff on proper maintenance procedures and safety protocols

  • Utilize predictive maintenance techniques such as vibration a...read more

Add your answer

Q14. Tell me about reverse alignment

Ans.

Reverse alignment is the process of aligning two machines in opposite directions.

  • Reverse alignment is used when two machines are required to operate in opposite directions.

  • It involves aligning the machines in a way that the coupling faces are parallel and at the same height.

  • Reverse alignment is important to prevent damage to the machines and ensure efficient operation.

  • It requires specialized tools and techniques such as laser alignment and dial indicators.

  • Examples of machines...read more

Add your answer

Q15. Hvac working principle

Ans.

HVAC systems work by transferring heat from one area to another using refrigerant to cool or heat the air.

  • HVAC systems use refrigerant to absorb and release heat

  • Air is circulated through ducts to distribute the cooled or heated air

  • Thermostats control the temperature settings of the HVAC system

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos

Interview Process at Fine Digital

based on 19 interviews
Interview experience
3.6
Good
View more
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories

Top Interview Questions from Similar Companies

3.4
 • 791 Interview Questions
3.8
 • 181 Interview Questions
3.6
 • 176 Interview Questions
4.0
 • 172 Interview Questions
4.0
 • 157 Interview Questions
3.7
 • 142 Interview Questions
View all
Top Bahwan Engineering Interview Questions And Answers
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter