Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Jul 2021. There were 3 interview rounds.
Top trending discussions
I applied via Walk-in and was interviewed in Nov 2023. There were 2 interview rounds.
A pH meter is a scientific instrument used to measure the acidity or alkalinity of a substance. Calibration ensures accurate readings.
pH meter measures the concentration of hydrogen ions in a solution
Calibration involves adjusting the pH meter to known standard solutions
Regular calibration ensures accurate readings over time
HPLC stands for High Performance Liquid Chromatography, which consists of a pump, injector, column, detector, and integrator.
HPLC involves a pump to push the liquid solvent through the system.
It includes an injector to introduce the sample into the mobile phase.
The column separates the components of the sample based on their interactions with the stationary phase.
A detector measures the amount of analyte in the eluent.
...
Buffers commonly used in HPLC include phosphate buffers, acetate buffers, and citrate buffers.
Phosphate buffers are commonly used in HPLC for separating acidic compounds.
Acetate buffers are used for separating basic compounds.
Citrate buffers are used for separating metal ions.
Other common buffers used in HPLC include ammonium acetate and ammonium formate.
HPLC calibration involves adjusting parameters to ensure accurate and reliable results.
Prepare standard solutions of known concentrations
Run the standard solutions through the HPLC system
Compare the results to expected values and adjust parameters as needed
Repeat the process until accurate and consistent results are obtained
I applied via Referral and was interviewed in Apr 2021. There was 1 interview round.
posted on 23 Jan 2021
I was interviewed before Jan 2020.
I applied via Walk-in and was interviewed in Nov 2023. There were 2 interview rounds.
A pH meter is a scientific instrument used to measure the acidity or alkalinity of a substance. Calibration ensures accurate readings.
pH meter measures the concentration of hydrogen ions in a solution
Calibration involves adjusting the pH meter to known standard solutions
Regular calibration ensures accurate readings over time
HPLC stands for High Performance Liquid Chromatography, which consists of a pump, injector, column, detector, and integrator.
HPLC involves a pump to push the liquid solvent through the system.
It includes an injector to introduce the sample into the mobile phase.
The column separates the components of the sample based on their interactions with the stationary phase.
A detector measures the amount of analyte in the eluent.
...
Buffers commonly used in HPLC include phosphate buffers, acetate buffers, and citrate buffers.
Phosphate buffers are commonly used in HPLC for separating acidic compounds.
Acetate buffers are used for separating basic compounds.
Citrate buffers are used for separating metal ions.
Other common buffers used in HPLC include ammonium acetate and ammonium formate.
HPLC calibration involves adjusting parameters to ensure accurate and reliable results.
Prepare standard solutions of known concentrations
Run the standard solutions through the HPLC system
Compare the results to expected values and adjust parameters as needed
Repeat the process until accurate and consistent results are obtained
posted on 22 Jun 2024
based on 15 reviews
Rating in categories
Executive
49
salaries
| ₹2.5 L/yr - ₹7 L/yr |
Senior Executive
17
salaries
| ₹5.3 L/yr - ₹8.5 L/yr |
Executive Production
14
salaries
| ₹2.9 L/yr - ₹6.2 L/yr |
Technical Assistant
6
salaries
| ₹2.2 L/yr - ₹3 L/yr |
Executive Microbiologist
4
salaries
| ₹3 L/yr - ₹3.2 L/yr |
Novartis Healthcare
Symbiotec Pharmalab
Aspiro Pharma
Bajaj Healthcare