I applied via Referral and was interviewed before Oct 2020. There were 3 interview rounds.
Transformers are tested for various parameters to ensure their proper functioning.
Measurement of winding resistance
Measurement of voltage ratio and turns ratio
Measurement of insulation resistance
Measurement of no-load current and losses
Measurement of load losses and impedance voltage
Measurement of temperature rise
Dielectric tests
PI test is a type of transformer testing that measures the insulation resistance and polarization index.
PI test is performed to determine the condition of insulation in transformers.
It involves measuring the insulation resistance and polarization index of the transformer.
The insulation resistance is measured by applying a DC voltage to the transformer winding and measuring the current.
The polarization index is the rati...
CT Secondary site is shorted to prevent damage to the CT and connected equipment.
Shorting CT Secondary site prevents high voltage from being induced in the secondary winding.
It also prevents damage to the CT and connected equipment due to high voltage.
Shorting is done during CT testing or maintenance.
Shorting can be done using a shorting link or a shorting switch.
Transformers are rated in KVA because it indicates the maximum amount of power that can be transferred through the transformer.
KVA rating is used to determine the maximum amount of power that can be transferred through the transformer
It takes into account both the voltage and current ratings of the transformer
KVA rating is important for selecting the appropriate transformer for a given application
For example, a 100 KVA...
Yes, I can draw the control diagram of Star Delta Starter.
The diagram consists of three contactors, a timer, and an overload relay.
In the starting position, the contactors are in the open position.
When the start button is pressed, the timer starts and the contactors close in a specific sequence.
After a set time, the contactors switch to the delta position.
The overload relay protects the motor from overloading.
The contr...
VFD stands for Variable Frequency Drive. It is an electronic device used to control the speed and torque of an electric motor.
VFD works by converting fixed frequency and voltage input into variable frequency and voltage output.
It uses power electronics to vary the frequency and voltage supplied to the motor, allowing for precise control of motor speed.
By adjusting the frequency and voltage, VFD can regulate the motor's...
Top trending discussions
I applied via Naukri.com and was interviewed in Sep 2020. There were 3 interview rounds.
The HashMap class is used to represent key-value pairs in Java.
HashMap is a part of the Java Collections Framework.
It allows null values and only one null key.
It provides constant-time performance for basic operations like get and put.
Example: HashMap<String, Integer> map = new HashMap<>();
Abstraction is the process of simplifying complex systems by focusing on essential details and hiding unnecessary complexities.
Abstraction allows us to create models or representations of real-world objects or systems in software.
It helps in managing complexity by breaking down a system into smaller, more manageable parts.
Abstraction provides a level of indirection, allowing changes to be made in one part of the system...
try-catch is used in Java to handle exceptions and prevent program crashes.
try-catch blocks are used to catch and handle exceptions that may occur during program execution.
It allows the program to gracefully handle errors and prevent the program from crashing.
The try block contains the code that may throw an exception, and the catch block handles the exception.
Multiple catch blocks can be used to handle different types...
The statement to use for selecting based on integer inputs is the 'switch' statement.
The 'switch' statement allows for multiple cases to be evaluated based on the value of an integer input.
Each case represents a possible value of the input, and the corresponding code block is executed if the value matches.
The 'switch' statement also provides a 'default' case which is executed if none of the cases match the input value.
...
I applied via Campus Placement and was interviewed in Oct 2020. There was 1 interview round.
I applied via Approached by company and was interviewed in Aug 2021. There were 2 interview rounds.
Quant focussed Case Study (be prepared for calculations)
I applied via Company Website and was interviewed before Oct 2020. There was 1 interview round.
I applied via Referral and was interviewed before Nov 2020. There were 3 interview rounds.
based on 12 reviews
Rating in categories
Supervisor
4
salaries
| ₹1.1 L/yr - ₹3.5 L/yr |
Accountant
3
salaries
| ₹1.5 L/yr - ₹3 L/yr |
Electrical Engineer
3
salaries
| ₹3.1 L/yr - ₹3.6 L/yr |
Office Assistant
3
salaries
| ₹1.5 L/yr - ₹1.5 L/yr |
Marpu Foundation
Huawei Technologies
HCL Infosystems
Z X Learning