Filter interviews by
I applied via Walk-in and was interviewed in Feb 2020. There was 1 interview round.
Small micro size columns are not used in daily routine analysis due to limitations in sample capacity and resolution.
Small micro size columns have limited sample capacity, which may not be sufficient for routine analysis that requires larger sample volumes.
These columns also have limited resolution, which may not be suitable for complex analyses that require high separation power.
Using larger columns allows for higher ...
Top trending discussions
I applied via Company Website and was interviewed in Sep 2024. There were 2 interview rounds.
posted on 21 Jan 2025
I applied via Walk-in and was interviewed in Jan 2024. There was 1 interview round.
I applied via Walk-in and was interviewed in Jul 2023. There was 1 interview round.
Granulation can be either wet or dry, with each method having its own advantages and disadvantages.
Granulation can be categorized as wet granulation or dry granulation.
Wet granulation involves the addition of a liquid binder to the powder mixture, followed by drying and sizing.
Dry granulation involves compacting the powder mixture without the use of liquid binders.
Examples of wet granulation include high-shear granulat...
Automation is the use of technology to perform tasks with minimal human intervention.
Automation involves the use of machines, software, and other technologies to carry out tasks that would otherwise be done by humans.
Examples of automation include robotic process automation (RPA), self-driving cars, and smart home devices.
Automation can increase efficiency, reduce errors, and save time and money for businesses.
FBD FBP and FBE are different types of insurance policies.
FBD (Full Business Day) insurance covers loss of income due to business interruption.
FBP (Full Business Protection) insurance covers both property damage and business interruption.
FBE (Full Business Enhancement) insurance offers additional coverage options to enhance a standard policy.
I applied via Naukri.com and was interviewed before Apr 2023. There were 2 interview rounds.
Saturation solubility is the maximum amount of solute that can dissolve in a solvent at a specific temperature.
Saturation solubility is influenced by temperature, pressure, and the chemical nature of the solute and solvent.
It is typically expressed in units of mass of solute per volume of solvent (e.g. g/L).
Factors affecting saturation solubility include the presence of impurities, pH of the solution, and the presence ...
The main sensor of an autoclave is a pressure sensor.
The pressure sensor monitors the pressure inside the autoclave to ensure it reaches the desired level for sterilization.
It helps in regulating the temperature and pressure during the sterilization process.
Common types of pressure sensors used in autoclaves include strain gauge pressure sensors and piezoelectric pressure sensors.
based on 4 reviews
Rating in categories
Officer
88
salaries
| ₹1.8 L/yr - ₹4 L/yr |