i
ABIS Exports
Filter interviews by
I was interviewed in Jan 2025.
Top trending discussions
posted on 19 Jan 2023
I applied via Company Website and was interviewed in Dec 2022. There were 2 interview rounds.
posted on 7 Oct 2022
I applied via Walk-in and was interviewed before Oct 2021. There were 4 interview rounds.
Working on live DB or Control panel requires proper training and safety measures.
Ensure that all safety procedures are followed before working on live equipment.
Use appropriate personal protective equipment (PPE) such as gloves, goggles, and insulated tools.
Identify the specific risks associated with the equipment and take necessary precautions.
Work with a partner who can assist in case of an emergency.
Avoid wearing an...
Yes, I am familiar with cable glanding and termination.
Cable glanding involves fitting a gland around the cable to provide a secure seal and prevent ingress of dust or moisture.
Termination involves connecting the cable to a device or equipment using appropriate connectors.
I have experience in selecting the right type of gland and connector based on the cable size and application requirements.
I am also familiar with the...
A star terminal motor has three terminals, with one end of each winding connected to a common point, forming a star shape.
A star terminal motor is a type of three-phase AC motor.
It has three terminals, labeled U, V, and W.
One end of each winding is connected to a common point, forming a star shape.
The other end of each winding is connected to a power supply.
This type of motor is also known as a Y-connected motor.
It is ...
PF stands for Power Factor, which is the ratio of real power to apparent power in an electrical system.
Power Factor is a measure of how efficiently electrical power is being used in a system.
It is expressed as a decimal or a percentage, with a value of 1 or 100% indicating perfect efficiency.
A low power factor can result in increased energy costs and reduced equipment lifespan.
Capacitors can be used to improve power fa...
Star and Delta connections are used in three-phase AC systems to control voltage and current.
Star connection is used when the load requires a lower voltage than the supply voltage.
Delta connection is used when the load requires the same voltage as the supply voltage.
Practically, star connection is achieved by connecting the three phases to a common point and the load to the other ends of the phases.
Delta connection is ...
based on 1 interview
Interview experience
Executive Accountant
63
salaries
| ₹1.8 L/yr - ₹5 L/yr |
Assistant Manager
41
salaries
| ₹3.8 L/yr - ₹8.5 L/yr |
Senior Executive
33
salaries
| ₹2.9 L/yr - ₹6.5 L/yr |
Branch Manager
27
salaries
| ₹3.6 L/yr - ₹6 L/yr |
Manager
21
salaries
| ₹4.6 L/yr - ₹12.5 L/yr |
Cargill
Mother Dairy Fruit & Vegetable
Amul India
Heritage Foods