Q1. When ud has done then how to add mic in result recording screen
To add MIC in result recording screen after UD, go to inspection lot, select MIC, enter result, save.
Go to the inspection lot in SAP QM module
Select the relevant MIC (Measuring Point) for which you want to record the result
Enter the result of the inspection
Save the result to update the MIC in the result recording screen
Q2. How to create inspection lot using 0101 type
To create inspection lot using 0101 type, use transaction code QA01 and enter the material number and plant.
Use transaction code QA01 to create inspection lot
Enter the material number and plant
Select inspection type 0101
Q3. Types of mic and differentiation them
There are various types of microphones, including dynamic, condenser, ribbon, and shotgun.
Dynamic microphones are durable and can handle high sound pressure levels.
Condenser microphones are more sensitive and provide a wider frequency response.
Ribbon microphones are known for their warm and natural sound.
Shotgun microphones have a narrow pickup pattern and are often used in film and TV production.
Q4. What is sample prcodeure
Sample procedure is a method used in quality management to determine the quality of a product by inspecting a sample of the product.
Sample procedure involves selecting a representative sample from a batch of products for inspection.
The sample is inspected according to predefined criteria to determine if it meets quality standards.
Results from the sample inspection are used to make decisions about the entire batch of products.
Sample procedure helps in ensuring consistent quali...read more