Q1. What is DG make and interface with your existing electrical network?
DG stands for Diesel Generator. It is used as a backup power source in case of power outages or emergencies.
DG is connected to the existing electrical network through an Automatic Transfer Switch (ATS)
The ATS detects when there is a power outage and automatically switches the power source from the main grid to the DG
Once the main power is restored, the ATS switches the power source back to the grid and the DG is turned off
The DG should be properly sized to meet the power requ...read more
Q2. What are the motor and transformer protection scheme
Motor and transformer protection schemes are used to prevent damage to the equipment and ensure safe operation.
Motor protection schemes include overload protection, short circuit protection, and earth fault protection.
Transformer protection schemes include overcurrent protection, differential protection, and earth fault protection.
Motor and transformer protection schemes can be achieved through the use of fuses, circuit breakers, relays, and other protective devices.
Proper ma...read more
Q3. What is the parameters check daily in a transformer ?
Parameters checked daily in a transformer include temperature, oil level, and cooling system.
Temperature of the transformer should be monitored to ensure it is within safe operating limits.
Oil level in the transformer should be checked to ensure proper lubrication and insulation.
Cooling system of the transformer should be inspected to ensure efficient heat dissipation.
Any abnormal noise or vibration should be investigated to prevent potential issues.
Regular visual inspection ...read more
Q4. What is reverse synchronisation relay?
Reverse synchronisation relay is a protective relay used to prevent the generator from being synchronized with the grid in the wrong direction.
It is used to prevent the generator from being synchronized with the grid in the wrong direction
It detects the reverse power flow from the grid to the generator
It trips the generator breaker if the reverse power flow exceeds a certain limit
It is important for the safety of the generator and the grid
Q5. ntroduction to existing electrical network.
The existing electrical network refers to the current system of electrical infrastructure in place.
The existing electrical network includes power generation, transmission, and distribution systems.
It may also include electrical equipment and devices such as transformers, switchgear, and meters.
The network may be owned and operated by a utility company or other entity.
The network may have limitations or challenges such as capacity constraints or outdated technology.
Improvement...read more
Q6. Type of transformer oil tests
Transformer oil tests include dielectric strength, acidity, interfacial tension, and dissolved gas analysis.
Dielectric strength test measures the ability of oil to withstand electrical stress
Acidity test determines the acidity level of oil
Interfacial tension test measures the oil's ability to separate from water
Dissolved gas analysis identifies the presence of gases in the oil, indicating potential faults in the transformer
Other tests include flash point, viscosity, and color
Share interview questions and help millions of jobseekers 🌟
Electrical Incharge Jobs
Interview Questions of Similar Designations
Interview experiences of popular companies
Calculate your in-hand salary
Confused about how your in-hand salary is calculated? Enter your annual salary (CTC) and get your in-hand salary
Reviews
Interviews
Salaries
Users/Month