Filter interviews by
I applied via Naukri.com and was interviewed in Jun 2023. There were 4 interview rounds.
Gel test process is a method used to analyze the physical and chemical properties of a gel material.
Gel test process involves preparing a sample of the gel material.
The sample is then subjected to various tests such as viscosity measurement, gel strength testing, and chemical analysis.
The results of the gel test process help in determining the quality and performance of the gel material.
Example: Gel test process can be...
Adhesion test is a method to measure the strength of adhesion between two materials, while peel test is a method to measure the force required to peel two materials apart.
Adhesion test involves applying a force to separate two materials bonded together and measuring the force required to do so.
Peel test specifically measures the force required to peel two materials apart at a specified angle.
Both tests are commonly use...
B.tech in (ECE ) Electronics and Communication Engineering
I applied via Company Website and was interviewed in Apr 2021. There were 3 interview rounds.
Top trending discussions
I applied via Walk-in and was interviewed in Feb 2024. There was 1 interview round.
I applied via Referral and was interviewed in Mar 2024. There were 2 interview rounds.
Possible reasons for cube failure despite good materials
Improper mixing of materials
Incorrect curing process
Inadequate compaction of concrete
Presence of air voids or impurities
Poor quality control during manufacturing
Compression test is conducted after cube test to determine the compressive strength of concrete.
Compression test is conducted to determine the compressive strength of concrete.
It involves applying a gradually increasing load to the concrete specimen until failure.
The results of the compression test help in assessing the quality of the concrete mix and its ability to withstand compressive forces.
Compression test is an i...
The quantity of cement used in M35 grade concrete varies depending on the mix design and specifications.
The quantity of cement in M35 grade concrete typically ranges from 360 to 420 kg/m3.
The exact amount of cement needed can be calculated using the mix design provided for the project.
Factors such as water-cement ratio, aggregate size, and admixtures also influence the quantity of cement required.
posted on 28 Jun 2024
I applied via Campus Placement
General aptitude online test
Renewable energies are sources of energy that are replenished naturally and can be used repeatedly without running out.
Renewable energies come from sources such as sunlight, wind, rain, tides, waves, and geothermal heat.
They are sustainable and environmentally friendly alternatives to fossil fuels.
Examples include solar power, wind power, hydropower, and biomass.
Renewable energies help reduce greenhouse gas emissions a
About your personal details.
Bulk density refers to the mass of a substance per unit volume, excluding any voids or air spaces.
It is a measure of how densely packed the particles or molecules are in a given volume.
Bulk density is commonly used in industries such as mining, agriculture, and pharmaceuticals.
It is calculated by dividing the mass of the substance by its volume.
For example, the bulk density of a soil sample can indicate its compaction ...
Target mean strength is the desired strength level of a product or material.
It is the strength level that a product or material is designed to meet or exceed.
It is determined based on the intended use and expected stresses on the product or material.
It is often used in quality control to ensure that products meet the desired strength level.
For example, the target mean strength of a steel beam used in construction may b...
There are several types of brick tests and corresponding IS codes.
Compressive strength test (IS code: IS 3495 Part 1)
Water absorption test (IS code: IS 3495 Part 2)
Efflorescence test (IS code: IS 3495 Part 3)
Dimensional tolerance test (IS code: IS 3495 Part 4)
Warpage test (IS code: IS 3495 Part 5)
Soundness test (IS code: IS 3495 Part 6)
Density test (IS code: IS 3495 Part 7)
I applied via Campus Placement and was interviewed in Nov 2020. There were 4 interview rounds.
posted on 1 Mar 2021
The welding procedure for P91 material involves preheating, maintaining interpass temperature, and post-weld heat treatment.
P91 material is a type of high-strength, low-alloy steel used in high-temperature applications.
The welding procedure for P91 material typically includes preheating the base metal to a specific temperature range.
Interpass temperature control is crucial to prevent cracking and maintain the mechanica...
A 1 gigawatt required pallet is a pallet that can handle the weight and power requirements of a 1 gigawatt load.
A 1 gigawatt required pallet needs to be able to support the weight of a 1 gigawatt load.
It should have a strong and sturdy construction to prevent any damage or collapse.
The pallet should be designed to handle the power requirements of a 1 gigawatt load, ensuring proper electrical connections and insulation.
...
Blocking diodes are used in junction boxes to prevent reverse current flow and protect electrical components.
Blocking diodes are used to prevent reverse current flow in electrical circuits.
They protect electrical components from damage caused by reverse voltage.
Blocking diodes are commonly used in junction boxes to ensure proper current flow.
They are also used in solar panels to prevent power loss due to reverse curren...
If module temperature increases, it can lead to reduced efficiency, increased stress on components, and potential failure.
Increased temperature can cause a decrease in the efficiency of the module.
Higher temperatures can lead to increased stress on components, potentially reducing their lifespan.
Excessive heat can cause thermal expansion and contraction, which may result in mechanical failure.
Increased temperature can ...
My life goal is to make a positive impact on society by ensuring quality in engineering processes.
To continuously improve and optimize engineering processes
To ensure products meet high quality standards
To contribute to the development of innovative and reliable solutions
To collaborate with cross-functional teams to drive quality improvements
To mentor and inspire others in the field of quality engineering
based on 3 reviews
Rating in categories
Electrical Engineer
51
salaries
| ₹1.7 L/yr - ₹5.9 L/yr |
Assistant Manager
49
salaries
| ₹5.4 L/yr - ₹10.3 L/yr |
Senior Manager
37
salaries
| ₹9.5 L/yr - ₹24 L/yr |
Senior Engineer
36
salaries
| ₹3.5 L/yr - ₹7.8 L/yr |
Manager
27
salaries
| ₹9 L/yr - ₹20 L/yr |
Adani Green Energy
Waaree Energies
Jakson Group
Azure Power