I applied via Campus Placement and was interviewed before Nov 2021. There were 3 interview rounds.
I don't even know 1 answer. blindly ticked
Discussion About the company and manufacturing industries details.
Top trending discussions
I applied via Naukri.com and was interviewed in Mar 2024. There were 4 interview rounds.
The question is testing the candidate's knowledge of present simple and present continuous tenses.
Present Simple is used for general truths, habits, and routines.
Present Continuous is used for actions happening now or around the present moment.
Examples: 'He cares for the equipment regularly.' (Present Simple) 'He is currently calling the supplier for spare parts.' (Present Continuous)
posted on 5 Nov 2023
I applied via Company Website and was interviewed in Jul 2023. There were 3 interview rounds.
MCB stands for Miniature Circuit Breaker. It is a type of electrical protection device that automatically switches off electrical circuits during abnormal conditions.
MCB is used to protect electrical circuits from overloads and short circuits.
It is a more convenient and reliable alternative to fuses.
MCBs come in different ratings to suit different electrical loads.
They can be easily reset after tripping, unlike fuses w...
Mcb is used for safety in both homes and companies. Safety wiring is essential for preventing electrical hazards.
Mcb (Miniature Circuit Breaker) is used in homes and companies to protect electrical circuits from overloads and short circuits.
Safety wiring, such as grounding wires and proper insulation, is crucial for preventing electrical shocks and fires.
Proper installation and maintenance of Mcbs and safety wiring are...
Maintenance work often requires the use of various tools and equipment.
Maintenance work may involve using tools such as screwdrivers, wrenches, pliers, multimeters, and power drills.
Different tools are used for different tasks, such as testing electrical circuits, tightening bolts, or replacing components.
Regular maintenance of equipment may require specialized tools specific to the machinery being serviced.
Proper tool...
Maintenance work often involves using electrical equipment such as tap cutters.
Regularly inspecting and cleaning electrical equipment to ensure proper functioning
Replacing worn out parts or components as needed
Testing equipment after maintenance to ensure it is working correctly
Following safety procedures when working with electrical equipment
Keeping a record of maintenance work done on each piece of equipment
posted on 20 Oct 2023
I applied via LinkedIn and was interviewed before Oct 2022. There were 4 interview rounds.
Air dryers are devices used to remove moisture from compressed air to prevent corrosion and damage to equipment.
Types of air dryers include refrigerated dryers, desiccant dryers, and membrane dryers
Refrigerated dryers work by cooling the air to condense and remove moisture
Desiccant dryers use a material like silica gel to absorb moisture from the air
Membrane dryers rely on a membrane to selectively permeate water vapor...
I applied via Recruitment Consulltant and was interviewed before Jun 2022. There were 5 interview rounds.
Basic questions with respect to your role
Checkpoints during breakdown
I applied via Referral and was interviewed before Feb 2023. There was 1 interview round.
posted on 6 Apr 2021
The voltage in three-phase power systems is typically 208 volts, 240 volts, or 480 volts.
Three-phase power systems are commonly used in industrial and commercial applications.
The voltage in a three-phase system depends on the specific application and the power requirements.
Common voltages in three-phase systems include 208 volts, 240 volts, and 480 volts.
Higher voltage levels are typically used for larger industrial eq...
The frequency in India is 50 Hz.
The frequency of electrical power in India is standardized at 50 Hz.
This frequency is used for both residential and commercial electricity supply.
It is important for electrical technicians to be familiar with this frequency when working with electrical systems in India.
I applied via Recruitment Consulltant and was interviewed in Nov 2022. There were 2 interview rounds.
To handle any breakdown, it is important to follow a systematic approach and have a good understanding of the equipment and its components.
Identify the cause of the breakdown by conducting thorough inspections and diagnostic tests.
Refer to equipment manuals and documentation to understand the functioning and troubleshooting procedures.
Use appropriate tools and equipment to repair or replace faulty components.
Ensure saf...
The lowest cooling capacity of an air conditioner depends on its BTU rating and the ambient temperature.
The cooling capacity of an air conditioner is measured in BTUs (British Thermal Units).
The lowest cooling capacity is determined by the BTU rating of the air conditioner.
The ambient temperature also affects the lowest cooling capacity.
Air conditioners with lower BTU ratings may have a lower lowest cooling capacity.
Fo...
posted on 7 Sep 2021
I applied via Recruitment Consultant and was interviewed in Mar 2021. There was 1 interview round.
Proximity sensors are devices that detect the presence or absence of an object within a certain range.
Proximity sensors use various technologies such as capacitive, inductive, ultrasonic, and optical to detect objects.
Capacitive proximity sensors detect objects by measuring changes in capacitance when an object enters the sensor's electric field.
Inductive proximity sensors use electromagnetic fields to detect metallic ...
Connect one relay to each push button and motor, and connect the relays in parallel to the SMPS for forward and reverse operation.
Connect one relay to each push button and motor
Connect the relays in parallel to the SMPS
Use the push buttons to control the relays and thus the motor direction
There are two main types of motors: AC motors and DC motors.
AC motors: synchronous and asynchronous
DC motors: brushed and brushless
Other types: stepper, servo, linear, etc.
Motors can also be classified by their power source, size, and application
There are several companies that produce PLCs. I have experience with Siemens and Allen Bradley PLCs.
Siemens and Allen Bradley are two of the most popular PLC manufacturers
I have experience running programs on both Siemens and Allen Bradley PLCs
Siemens TIA Portal and Allen Bradley Studio 5000 are both user-friendly software for programming PLCs
Power factor is a measure of how effectively electrical power is being used. It can be improved by using power factor correction techniques.
Power factor is the ratio of real power to apparent power in an electrical system.
It indicates the efficiency of electrical power usage.
A power factor of 1 indicates all the power is being used effectively, while a power factor less than 1 indicates inefficiency.
Power factor can be...
Yes, I am familiar with Digital Multimeter and can demonstrate its usage for different components.
For HV diode, set the multimeter to resistance mode and connect the probes to the diode terminals. The multimeter should show a low resistance value in one direction and high resistance in the other direction.
For HV capacitor, set the multimeter to capacitance mode and connect the probes to the capacitor terminals. The mul...
Servo motors are used for high precision control while stepper motors are used for low speed and high torque applications.
Servo motors have a closed-loop system while stepper motors have an open-loop system.
Servo motors have higher accuracy and precision than stepper motors.
Stepper motors have a higher torque output than servo motors.
Servo motors are more expensive than stepper motors.
Examples of servo motors include A...
Trainee
107
salaries
| ₹1.8 L/yr - ₹3.5 L/yr |
Assistant Engineer
83
salaries
| ₹2 L/yr - ₹9 L/yr |
Production Engineer
55
salaries
| ₹1.8 L/yr - ₹10.9 L/yr |
Diploma Trainee Engineer
39
salaries
| ₹1.3 L/yr - ₹4 L/yr |
Team Lead
36
salaries
| ₹3 L/yr - ₹12 L/yr |
Mahindra & Mahindra
Tata Motors
Ashok Leyland
Bharat Forge