kVA is the total power in a circuit, while KVAR is the reactive power in a circuit.
kVA is the apparent power in a circuit, which is the combination of real power (kW) and reactive power (KVAR).
KVAR is the reactive power in a circuit, which is the power that oscillates between the load and the source without being consumed.
kVA is used to size the electrical equipment, while KVAR is used to correct the power factor of th...
Nitrogen gas is used in suspension cylinder to prevent foaming and cavitation.
Nitrogen gas is used as a cushion to prevent the formation of air bubbles in the hydraulic fluid.
It also prevents cavitation, which can cause damage to the cylinder and reduce its efficiency.
Nitrogen gas is non-reactive and does not corrode the cylinder, making it a suitable choice for suspension systems.
Examples of suspension systems that us...
The Skelton system is a mechanism used in 100 ton dumpers for efficient unloading of materials.
The Skelton system uses a hydraulic cylinder to lift the dumper bed and dump the materials.
It is designed to handle heavy loads and withstand harsh working conditions.
The system is controlled by an operator using a control panel.
Regular maintenance is required to ensure the system operates smoothly and safely.
Top trending discussions
I appeared for an interview before Jan 2021.
Composite error and ratio error are two types of errors in current transformers.
Composite error is the combination of ratio error and phase angle error in a current transformer.
Ratio error is the difference between the actual turns ratio and the specified turns ratio of a current transformer.
Phase angle error is the angular difference between the primary and secondary currents of a current transformer.
Composite error a...
An AC drive circuit diagram controls the speed of an AC motor by varying the frequency and voltage of the power supplied to it.
An AC drive consists of a rectifier, DC link, inverter, and control circuitry.
The rectifier converts AC power to DC power, which is stored in the DC link.
The inverter converts the DC power back to AC power with variable frequency and voltage.
The control circuitry adjusts the frequency and volta...
A single line diagram of a distribution system is required with proper specifications.
The diagram should show the flow of power from the source to the load
It should include all components such as transformers, switchgear, and cables
The specifications should include voltage levels, power ratings, and protection devices
The diagram should follow standard symbols and conventions
Example: A 11 kV distribution system with a 5
Dewpoint test is done in transformer to check the moisture content in the insulation oil.
Moisture in insulation oil can cause breakdown of transformer insulation
Dewpoint test helps to determine the moisture content in the oil
It is a preventive maintenance measure to avoid transformer failure
The test involves cooling a mirror until dew forms on it, and measuring the temperature at which dew forms
Power transformers are used in transmission systems to step up or down voltage, while distribution transformers are used in distribution systems to step down voltage.
Power transformers are used in high voltage transmission systems to step up or down voltage for long distance transmission.
Distribution transformers are used in low voltage distribution systems to step down voltage for local distribution.
Power transformers...
Buchholz relay is used to protect transformers from faults by detecting gas and oil flow abnormalities.
Buchholz relay is installed in the pipe connecting the transformer tank and conservator tank.
It operates based on the principle that faults in the transformer generate gases and cause oil flow disturbances.
When gas or oil flow abnormalities occur, the relay trips and sends a signal to the control panel to isolate the ...
I applied via Approached by Company and was interviewed before May 2021. There were 3 interview rounds.
I applied via Approached by Company and was interviewed in Jul 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in May 2021. There was 1 interview round.
posted on 29 Nov 2022
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
posted on 21 Sep 2023
I applied via Campus Placement and was interviewed in Mar 2023. There were 3 interview rounds.
posted on 26 Feb 2024
I applied via Approached by Company and was interviewed in Aug 2023. There were 2 interview rounds.
I applied via Company Website and was interviewed in Mar 2022. There were 3 interview rounds.
based on 3 reviews
Rating in categories
Assistant Manager
17
salaries
| ₹4.5 L/yr - ₹10.5 L/yr |
Electrical Engineer
16
salaries
| ₹3.2 L/yr - ₹6.6 L/yr |
Mechanical Engineer
11
salaries
| ₹3.2 L/yr - ₹4.8 L/yr |
Assistant Mines Manager
7
salaries
| ₹4.6 L/yr - ₹7.5 L/yr |
Deputy Manager
7
salaries
| ₹6.8 L/yr - ₹10.2 L/yr |
Adani Enterprises
Hindustan Zinc
Vedanta Limited
Coal India