Thermax Limited
Fasteners Allied Products Interview Questions and Answers
Q1. Tell the interlock and permissive of boiler and turbine?
Interlocks and permissives are safety mechanisms in place to prevent unsafe operation of boiler and turbine systems.
Interlocks prevent certain actions from taking place unless specific conditions are met
Permissives allow certain actions to take place only if specific conditions are met
Example of interlock: Boiler feed pump interlock prevents the boiler from starting unless the feed pump is running
Example of permissive: Turbine start permissive allows the turbine to start only...read more
Q2. Which are the equipment used in steam turbine? And their principal and working and troubleshooting?
Equipment used in steam turbine include turbine blades, nozzles, casing, rotor, bearings, and governor.
Turbine blades: convert steam energy into mechanical energy
Nozzles: control the flow of steam into the turbine
Casing: contains and directs the steam flow through the turbine
Rotor: connected to the turbine blades and rotates to generate power
Bearings: support the rotor and reduce friction
Governor: regulates the speed of the turbine
Q3. How to assign new chennal in Honeywell DCS ?
To assign a new channel in Honeywell DCS, you need to access the configuration software and follow the steps to add the channel.
Access the Honeywell DCS configuration software
Navigate to the channel configuration section
Add a new channel by specifying the channel number, type, and other relevant parameters
Save the changes and verify the new channel is successfully assigned
Q4. Tell us about the Woodward 505 ?
Woodward 505 is a versatile control system used in industrial applications.
The Woodward 505 is a widely used control system in industries such as power generation, oil and gas, and marine.
It offers advanced features like PID control, sequencing, and communication capabilities.
The Woodward 505 is known for its reliability and robustness in harsh operating environments.
It can be easily integrated with various types of sensors and actuators for precise control.
Q5. What is PID and How does it work ?
PID stands for Proportional-Integral-Derivative, a control loop feedback mechanism used in engineering.
PID is a control algorithm that calculates an error value as the difference between a desired setpoint and a measured process variable.
Proportional (P) control responds to the current error value.
Integral (I) control accumulates past errors to correct the present error.
Derivative (D) control predicts future errors based on the rate of change of the error.
The combined use of ...read more
Q6. Explain the structure of the Honeywell DCS ?
The Honeywell DCS (Distributed Control System) is a modular system consisting of controllers, I/O modules, and operator stations.
Consists of controllers, I/O modules, and operator stations
Uses a network to communicate between components
Allows for centralized control and monitoring of processes
Supports various communication protocols such as Modbus, OPC, etc.
Example: Honeywell Experion PKS
Q7. DCS tag assigning process
DCS tag assigning process involves assigning unique names to process variables for monitoring and control.
DCS tag assigning process is crucial for efficient process control and monitoring.
Each tag represents a process variable and is assigned a unique name for easy identification.
Tags can be assigned manually or automatically based on the process requirements.
Tag naming conventions should be consistent and follow industry standards.
Examples of DCS tags include FT-101 (flow tr...read more
Top Senior Engineer Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month