Filter interviews by
Be the first one to contribute and help others!
posted on 18 Jul 2024
I applied via Naukri.com and was interviewed in Jan 2024. There was 1 interview round.
Percentage impedance is a measure of a transformer's ability to limit short-circuit currents and is related to its performance.
Percentage impedance is the ratio of the transformer's impedance to its rated voltage.
It is a measure of the transformer's ability to limit short-circuit currents and protect the system.
A higher percentage impedance indicates a higher impedance and better protection against short-circuit curren...
Short circuit is an abnormal connection between two nodes of an electric circuit that results in excessive current flow.
Short circuit occurs when a low-resistance path is created between two points in an electrical circuit.
Short circuit current is calculated using Ohm's Law: I = V/R, where I is the current, V is the voltage, and R is the resistance.
Short circuit current can also be calculated by dividing the voltage by...
T&D losses refer to Transmission and Distribution losses, while AT&C losses refer to Aggregate Technical and Commercial losses.
T&D losses are the losses that occur when electricity is transmitted and distributed from power plants to consumers.
AT&C losses include technical losses (due to inefficient equipment and infrastructure) and commercial losses (due to theft and billing inefficiencies).
Reducing T&D and AT&C losses...
Standard Performance indices are metrics used to measure and evaluate the performance of an individual, team, or organization.
Standard Performance indices are quantitative measures used to assess the efficiency, effectiveness, and quality of performance.
They provide a benchmark for comparison and help in identifying areas for improvement.
Examples include Key Performance Indicators (KPIs), Balanced Scorecard metrics, an...
posted on 25 Oct 2024
I applied via Walk-in and was interviewed before Mar 2020. There were 3 interview rounds.
Wind turbines convert wind energy into electricity through the rotation of blades connected to a generator.
Wind turns the blades of the turbine
Blades are connected to a generator
Generator converts mechanical energy into electricity
One major challenge in current wind farms is optimizing energy production while minimizing environmental impact.
Balancing energy production with environmental concerns
Efficiently integrating renewable energy sources into the grid
Mitigating noise and visual impacts on local communities
Addressing wildlife conservation and habitat disruption
Dealing with intermittency and variability of wind power
posted on 21 Feb 2024
A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction.
Transformers are commonly used to step up or step down voltage in electrical power distribution.
They consist of two coils of wire, known as the primary and secondary coils, wrapped around a core.
The primary coil is connected to a source of alternating current, which creates a changing magnetic field...
Transformers are classified based on their construction and purpose, such as power transformers, distribution transformers, and instrument transformers.
Power transformers are used to step up or step down voltage for transmission and distribution of electricity.
Distribution transformers are used to supply lower voltage to end-users.
Instrument transformers are used for measuring voltage and current in power systems.
Other...
An inverter is an electronic device that converts direct current (DC) to alternating current (AC).
Converts DC power to AC power
Used in solar power systems to convert DC electricity from solar panels to AC electricity for use in homes
Commonly used in uninterruptible power supplies (UPS) to provide backup power during outages
The type of inverter used is a grid-tied inverter.
Grid-tied inverters are connected to the utility grid and do not require batteries.
They convert DC power from solar panels into AC power for use in the home or to be fed back into the grid.
Examples of grid-tied inverters include string inverters, microinverters, and power optimizers.
Op amp stands for operational amplifier, a type of electronic amplifier with high gain and differential inputs.
Op amp is a type of amplifier that amplifies the difference in voltage between its two inputs.
It has a very high open-loop gain, typically around 100,000.
Op amps are commonly used in signal conditioning, filtering, and mathematical operations in electronic circuits.
Examples of op amp ICs include the LM741, AD8
Transformer design involves creating efficient and reliable electrical transformers for various applications.
Consider the desired voltage and current ratings for the transformer
Select appropriate core and winding materials for optimal performance
Design the transformer to minimize losses and improve efficiency
Perform simulations and testing to validate the design
Iterate on the design to meet specifications and requireme
posted on 14 May 2024
I applied via Walk-in and was interviewed in Apr 2024. There were 3 interview rounds.
Related previous company
posted on 20 Jun 2024
All types of questions are asked
Current affairs topics
posted on 14 Mar 2024
I applied via Company Website and was interviewed in Feb 2024. There was 1 interview round.
Motor testing equipment is commonly known as a megohmmeter or insulation tester.
Commonly known as a megohmmeter or insulation tester
Used to measure the insulation resistance of motors
Helps identify potential issues before they cause motor failure
posted on 12 Feb 2023
I applied via LinkedIn and was interviewed in Jan 2024. There were 2 interview rounds.
Various foundations involved in station management include government funding, private donations, grants, and corporate sponsorships.
Government funding: Provides financial support for station operations and infrastructure.
Private donations: Contributions from individuals or organizations to support station programming.
Grants: Funding awarded by government agencies or private foundations for specific projects or initiat...
based on 16 reviews
Rating in categories
Lead Engineer
11
salaries
| ₹4 L/yr - ₹11.6 L/yr |
Assistant Manager
7
salaries
| ₹11 L/yr - ₹13.5 L/yr |
Associate Finance & Accounts
5
salaries
| ₹3.6 L/yr - ₹7.5 L/yr |
Diploma Trainee Engineer
4
salaries
| ₹2.8 L/yr - ₹5 L/yr |
Company Secretary
4
salaries
| ₹12 L/yr - ₹25 L/yr |
Adani Power
JSW Energy
NTPC
Reliance Power