Machine maintenance involves regular inspections, cleaning, lubrication, and repairs to ensure optimal performance and prevent breakdowns.
Create a maintenance schedule to track tasks and ensure they are completed on time.
Perform regular inspections to identify any signs of wear, damage, or malfunction.
Clean machines regularly to remove dirt, dust, and debris that can affect performance.
Lubricate moving parts to reduce ...
The frequency of machine maintenance depends on various factors such as machine type, usage, and manufacturer's recommendations.
Machine maintenance schedules can vary from daily, weekly, monthly, quarterly, or annually.
Some machines may require maintenance after a certain number of operating hours or cycles.
Manufacturer's guidelines and maintenance manuals provide specific recommendations for each machine.
Regular maint...
Before 90 days, I would perform initial setup, testing, and calibration of the machine.
Perform initial setup of the machine, including installation and configuration of electrical components.
Conduct testing to ensure all electrical systems are functioning properly.
Calibrate the machine to ensure accurate measurements and performance.
Inspect and troubleshoot any potential issues or defects.
Create a maintenance schedule ...
posted on 6 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Feb 2023. There were 3 interview rounds.
Self Introduction and communication English
posted on 28 Jul 2021
posted on 15 Jul 2021
I appeared for an interview in Jan 2025.
posted on 16 Jun 2023
I applied via Walk-in and was interviewed before Jun 2022. There were 3 interview rounds.
A synchronisation panel for DG is used to synchronize multiple generators to ensure they are running in parallel and sharing the load evenly.
Synchronisation panels are used in situations where multiple diesel generators need to be connected in parallel to supply power to a common bus.
The panel monitors the frequency, voltage, and phase angle of each generator and ensures they are synchronized before connecting them to ...
Pulse width in laser refers to the duration of time that a laser beam is emitted.
Pulse width is measured in seconds or milliseconds.
It determines the amount of energy delivered by the laser beam.
Shorter pulse widths are often used for precision cutting or welding.
Longer pulse widths are used for applications like material processing or drilling.
BDV stands for Breakdown Voltage. It is a measure of the dielectric strength of transformer oil.
BDV is the voltage at which the insulation between two conductors breaks down.
It is an important parameter to determine the quality of transformer oil.
BDV is usually measured in kilovolts (kV).
Higher BDV indicates better quality and higher dielectric strength of the oil.
RTCC panel stands for Remote Tap Changing Control panel, used in power transformers to automatically adjust the voltage ratio.
RTCC panel monitors the load and voltage levels of the transformer.
It automatically adjusts the tap changer to maintain the desired voltage ratio.
RTCC panel can be programmed to operate based on specific parameters like load current, temperature, etc.
It helps in optimizing the transformer perfor...
posted on 27 Jun 2023
posted on 15 Jan 2024
An induction motor is an AC electric motor in which power is supplied to the rotor by electromagnetic induction.
Induction motors are widely used in various applications, including industrial machinery, appliances, and transportation systems.
They work on the principle of electromagnetic induction, where a rotating magnetic field is created in the stator, inducing current in the rotor.
The rotor of an induction motor can ...
Sensors are devices that detect and respond to physical inputs or changes in the environment.
Temperature sensors measure the heat or coldness of an object or environment.
Pressure sensors measure the force exerted on a surface.
Proximity sensors detect the presence or absence of an object within a certain range.
Motion sensors detect movement or changes in position.
Light sensors measure the intensity or presence of light.
...
posted on 26 Nov 2021
I applied via Walk-in and was interviewed before Nov 2020. There were 3 interview rounds.
based on 1 review
Rating in categories
Assistant Engineer
2.7k
salaries
| ₹1.5 L/yr - ₹4 L/yr |
Deputy Engineer
1.8k
salaries
| ₹1.5 L/yr - ₹4.6 L/yr |
Diploma Trainee Engineer
917
salaries
| ₹1.2 L/yr - ₹3 L/yr |
Engineer
413
salaries
| ₹1.8 L/yr - ₹7.8 L/yr |
Production Engineer
347
salaries
| ₹1.2 L/yr - ₹6.8 L/yr |
JBM Group
Endurance Technologies
Spark Minda
Gabriel India