Transformers over load capacity can lead to overheating, damage, and potential failure.
Overloading a transformer can cause overheating and damage to the insulation
Excessive current flow can lead to increased losses and reduced efficiency
Regular maintenance and monitoring of load capacity is essential to prevent failures
Examples: If a transformer is rated for 100 kVA but is consistently loaded at 120 kVA, it is operatin
Top trending discussions
I applied via Walk-in and was interviewed before Mar 2023. There was 1 interview round.
Star delta starter is a method used to reduce the starting current of induction motors.
Star delta starter is used for starting induction motors in applications where the starting current needs to be limited.
In star connection, the motor windings are connected in a star configuration during starting to reduce the voltage across each winding.
After a certain time, the windings are switched to a delta configuration to run ...
Motor current formulas can be found using basic electrical principles and motor specifications.
Use Ohm's Law (I = V / R) to calculate current based on voltage and resistance.
For AC motors, use the formula I = P / (sqrt(3) * V * cos(theta)), where P is power, V is voltage, and theta is the power factor angle.
Refer to motor datasheets for specific current ratings and calculations.
Consider factors like efficiency, power f...
Protection in a transformer involves measures to prevent damage from overcurrent, overvoltage, and overheating.
Use fuses or circuit breakers to protect against overcurrent
Install surge arresters to protect against overvoltage
Use temperature sensors and cooling systems to prevent overheating
Implement differential protection to detect internal faults
Regular maintenance and testing to ensure proper functioning
Faults in a transformer can include short circuits, open circuits, overheating, and insulation breakdown.
Short circuits can occur due to insulation failure or winding damage.
Open circuits can result from broken connections or faulty windings.
Overheating may be caused by overloading or poor cooling.
Insulation breakdown can lead to arcing and short circuits.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
DCS Engineer
15
salaries
| ₹2.5 L/yr - ₹7.1 L/yr |
Deputy Manager
14
salaries
| ₹6.5 L/yr - ₹12.8 L/yr |
Shift Incharge
13
salaries
| ₹1.8 L/yr - ₹7.8 L/yr |
QC Chemist
12
salaries
| ₹1.8 L/yr - ₹4 L/yr |
Chemist
11
salaries
| ₹2 L/yr - ₹3.1 L/yr |
Gujarat Fluorochemicals
Pidilite Industries
Tata Chemicals
UPL