Q1. What are Fleming's Left Hand Rule and Right Hand Rule in electromagnetism?

Ans.

Fleming's Left Hand Rule and Right Hand Rule are used to determine the direction of force, current, or magnetic field in electromagnetism.

  • Fleming's Left Hand Rule is used to determine the direction of force on a current-carrying conductor in a magnetic field.

  • Fleming's Right Hand Rule is used to determine the direction of induced current in a conductor moving in a magnetic field.

  • Both rules are based on the relationship between the magnetic field, current, and force in electrom...read more

Add your answer

Q2. What are the safety devices used in conveyor belts and how are they wired?

Ans.

Safety devices used in conveyor belts include pull cord switches, belt sway switches, and emergency stop switches.

  • Pull cord switches are used to stop the conveyor belt in case of emergency by pulling the cord.

  • Belt sway switches are used to detect any misalignment or deviation of the belt and trigger an alarm or stop the conveyor.

  • Emergency stop switches are placed at regular intervals along the conveyor belt to quickly stop the operation in case of emergency.

Add your answer

Q3. What are the common malfunctions and troubleshooting methods for electrical feeders?

Ans.

Common malfunctions and troubleshooting methods for electrical feeders

  • Common malfunctions include short circuits, overloads, and open circuits

  • Troubleshooting methods involve checking for loose connections, using a multimeter to test for continuity, and inspecting for physical damage

  • In case of a short circuit, isolate the fault by disconnecting sections of the feeder until the fault is located

  • For overloads, check the load distribution and consider redistributing the load or up...read more

Add your answer

Q4. What is the minimum megger value required for high tension (HT) and low tension (LT) motors?

Ans.

The minimum megger value required for high tension (HT) and low tension (LT) motors is typically 500V for HT motors and 250V for LT motors.

  • Minimum megger value for HT motors is usually 500V

  • Minimum megger value for LT motors is typically 250V

  • Megger testing is essential to ensure insulation resistance in motors

Add your answer
Discover DataCare interview dos and don'ts from real experiences

Q5. Does a Megger generate AC or DC, and what is the reason for its output?

Ans.

A Megger generates DC voltage to test insulation resistance in electrical systems.

  • A Megger generates DC voltage typically ranging from 250V to 5000V

  • The reason for using DC voltage is to accurately measure the insulation resistance of electrical systems

  • DC voltage helps in detecting any insulation faults or breakdowns in the system

  • The high voltage generated by a Megger helps in identifying potential issues before they cause major problems

Add your answer

Q6. How can the Megger value of a found unsatisfactory insulation be improved?

Ans.

The Megger value of unsatisfactory insulation can be improved by drying out the insulation, repairing any damaged areas, and retesting.

  • Dry out the insulation using heaters or fans to remove moisture

  • Repair any damaged areas by replacing or patching up the insulation

  • Retest the insulation using the Megger to ensure the value has improved

  • Consider using insulation coatings or sealants to improve the insulation resistance

Add your answer
Are these interview questions helpful?

Q7. What steps should be taken if a transformer trips due to the Buchholz relay acting?

Ans.

Steps to be taken if a transformer trips due to Buchholz relay acting

  • Immediately isolate the transformer from the system to prevent further damage

  • Inspect the transformer and Buchholz relay for any faults or leaks

  • Reset the Buchholz relay and check for proper functioning

  • Investigate the cause of the trip such as internal faults or oil contamination

  • Repair or replace any faulty components before re-energizing the transformer

Add your answer

Q8. What is the working principle of motors and generators?

Ans.

Motors convert electrical energy into mechanical energy, while generators convert mechanical energy into electrical energy.

  • Motors work on the principle of electromagnetic induction, where a current-carrying conductor experiences a force in a magnetic field.

  • Generators work on the principle of Faraday's law of electromagnetic induction, where a changing magnetic field induces an electromotive force in a conductor.

  • Motors and generators both involve the interaction between magnet...read more

Add your answer
Share interview questions and help millions of jobseekers 🌟

Q9. What is the control circuit of a star-delta starter?

Ans.

The control circuit of a star-delta starter involves two contactors and a timer for smooth transition from star to delta connection.

  • The control circuit includes a main contactor for connecting the motor in star during starting.

  • A timer is used to delay the transition from star to delta connection to prevent sudden voltage spikes.

  • Once the timer elapses, a delta contactor is energized to switch the motor windings from star to delta configuration.

  • This control circuit ensures a sm...read more

Add your answer

Q10. What activities are involved in electrical preventive maintenance?

Ans.

Electrical preventive maintenance activities include inspection, testing, cleaning, and replacement of components to prevent breakdowns.

  • Regular inspection of electrical systems

  • Testing of equipment for proper functioning

  • Cleaning of electrical components to prevent dust buildup

  • Replacement of worn out or damaged parts

  • Tightening of connections to prevent loose connections

  • Checking for overheating issues

  • Updating software/firmware as needed

  • Implementing safety measures to prevent acc...read more

Add your answer

Q11. What are the maintenance practices for transformers?

Ans.

Maintenance practices for transformers include regular inspections, testing, cleaning, and oil analysis.

  • Regularly inspecting for signs of overheating, leaks, or damage

  • Performing routine testing such as insulation resistance and turns ratio tests

  • Keeping the transformer and surrounding area clean and free of debris

  • Conducting oil analysis to monitor the condition of the transformer oil

  • Ensuring proper ventilation and cooling of the transformer

  • Checking and tightening connections a...read more

Add your answer

Q12. What are the protective measures for a transformer?

Ans.

Protective measures for a transformer include overcurrent protection, temperature monitoring, and regular maintenance.

  • Overcurrent protection: Use fuses or circuit breakers to protect against excessive current flow.

  • Temperature monitoring: Install temperature sensors to prevent overheating.

  • Regular maintenance: Inspect and test the transformer regularly to ensure proper functioning.

  • Grounding: Properly ground the transformer to prevent electrical shocks and damage.

  • Oil level monit...read more

Add your answer

Q13. What is the working principle of a transformer?

Ans.

A transformer works on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.

  • Transformers have two coils of wire, known as the primary and secondary coils, which are wound around a core made of ferromagnetic material.

  • When an alternating current flows through the primary coil, it creates a changing magnetic field around the coil.

  • This changing magnetic field induces a voltage in the secondary coil through electromagnetic induction...read more

Add your answer

Q14. What is the generator excitation system?

Ans.

The generator excitation system is a system that provides the necessary field current to the generator rotor to produce the desired voltage output.

  • The excitation system controls the magnetic field strength of the generator to regulate the output voltage.

  • It typically consists of an exciter, voltage regulator, and automatic voltage regulator (AVR).

  • The exciter produces the field current, the voltage regulator adjusts the excitation level based on load changes, and the AVR mainta...read more

Add your answer

Q15. What is the bus changeover scheme?

Ans.

Bus changeover scheme is a system used to transfer power supply from one source to another in case of a fault or maintenance.

  • Bus changeover scheme involves the use of automatic transfer switches (ATS) or manual switches to transfer power sources.

  • It ensures uninterrupted power supply by quickly switching to an alternate power source when needed.

  • Common examples include dual power supply systems in data centers or hospitals.

  • The scheme is designed to prevent power outages and min...read more

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions
Get AmbitionBox app

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter