Filter interviews by
I applied via Naukri.com and was interviewed in Mar 2024. There were 2 interview rounds.
Top trending discussions
posted on 28 Jul 2024
MCB stands for Miniature Circuit Breaker. Types include single pole, double pole, triple pole, and four pole. Functions include overcurrent protection and short circuit protection.
Types of MCBs: single pole, double pole, triple pole, four pole
Functions: overcurrent protection, short circuit protection
Examples: Single pole MCB for individual circuits, four pole MCB for three-phase circuits
The current in a 3 phase system depends on the voltage and power of the system.
The current in a 3 phase system can be calculated using the formula: I = P / (sqrt(3) * V)
Where I is the current, P is the power, and V is the voltage
For example, if the power is 1000W and the voltage is 240V, the current would be approximately 4.33A
MCB stands for Miniature Circuit Breaker, a device designed to protect electrical circuits from overloads and short circuits.
MCB is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions like overload or short circuit.
It is commonly used in residential and commercial electrical installations to protect wiring and electrical equipment.
MCBs are available in different curr...
To check AC DC current, use a multimeter set to the appropriate setting and connect the probes to the circuit being tested.
Set the multimeter to the AC or DC current setting depending on what you are testing.
Ensure the multimeter probes are connected correctly to the circuit being tested.
Read the current measurement displayed on the multimeter.
For AC current, make sure the multimeter is set to the appropriate range (e....
To check cable continuity, use a multimeter to measure resistance between two points on the cable.
Use a multimeter set to the resistance or continuity mode.
Connect one probe to one end of the cable and the other probe to the other end.
A low resistance reading indicates good continuity, while a high resistance or infinite reading indicates a break in the cable.
Check for continuity in each conductor of the cable separate...
PVC stands for Polyvinyl Chloride, a type of plastic commonly used in construction and electrical applications.
PVC is a versatile material known for its durability and resistance to chemicals.
It is commonly used in electrical wiring, plumbing pipes, and vinyl flooring.
PVC is lightweight, easy to install, and cost-effective compared to other materials.
Examples of PVC products include PVC pipes, PVC electrical conduits,
The motor work in AC is based on electromagnetic induction, while in DC it is based on the Lorentz force principle.
AC motors work on the principle of electromagnetic induction, where a changing magnetic field induces a current in the rotor coils.
DC motors operate based on the Lorentz force principle, where a current-carrying conductor in a magnetic field experiences a force.
Examples of AC motors include induction motor...
I was interviewed in May 2023.
Rewinding a 72 slot 50 hp motor involves disassembling the motor, removing the old windings, and replacing them with new windings.
Disassemble the motor carefully to access the windings
Remove the old windings without damaging the core
Calculate the number of turns and wire gauge needed for the new windings
Wind the new coils carefully and evenly in the slots
Connect the windings properly and test the motor for functionalit
NO NC stands for Normally Open and Normally Closed. They refer to the state of a switch or relay when it is not activated.
NO (Normally Open) - the switch is open (off) when not activated
NC (Normally Closed) - the switch is closed (on) when not activated
Used in electrical circuits to control the flow of current
Commonly used in control panels, automation systems, and safety circuits
Earthing points are checked by using a multimeter to measure the resistance between the earthing point and the earth electrode.
Use a multimeter set to the resistance mode
Connect one probe to the earthing point and the other probe to the earth electrode
Check the resistance reading on the multimeter
A low resistance reading indicates a good earthing connection
Repeat the process for all earthing points in the system
Fan rewinding is the process of replacing the copper wire coils in the stator of a fan motor to restore its functionality.
Disconnect the fan from the power source before starting the rewinding process.
Remove the fan blades and outer casing to access the stator.
Carefully unwind the old copper wire coils from the stator and measure their length and gauge.
Select the appropriate gauge and length of copper wire for rewindin...
A contactor relay is an electrical device used to control a high-power circuit with a low-power signal.
Contactor relay consists of a coil, contacts, and an enclosure.
When the coil is energized, it creates a magnetic field that pulls the contacts together to close the circuit.
Contactor relays are commonly used in motor control circuits to start and stop motors.
They can also be used in lighting control, heating systems,
I applied via Walk-in and was interviewed in Jan 2022. There was 1 interview round.
posted on 12 Oct 2023
I applied via Walk-in and was interviewed in Sep 2023. There were 3 interview rounds.
How to make new project in R&D
I applied via Company Website and was interviewed in Jul 2023. There was 1 interview round.
An encoder is a device or circuit that converts information from one format to another.
An encoder can be a hardware device or a software program.
In the context of electrical engineering, an encoder is often used to convert analog signals into digital signals.
Encoders are commonly used in communication systems, robotics, and industrial automation.
Examples of encoders include rotary encoders used in motor control and opt
posted on 26 Oct 2024
Maths and basic puzzles
I applied via Walk-in and was interviewed in Mar 2022. There were 2 interview rounds.
An encoder is a device that converts motion into an electrical signal. A proxy is a server that acts as an intermediary for requests from clients.
Encoders are used in various applications such as robotics, automation, and CNC machines.
Proxies are commonly used in computer networks to improve security and performance.
An example of an encoder is a rotary encoder that converts the rotational motion of a shaft into an elec...
To check a transformer, perform visual inspection, measure voltage and current, and test insulation resistance.
Perform a visual inspection of the transformer for any physical damage or signs of overheating.
Measure the voltage and current using a multimeter to ensure they are within the rated values.
Test the insulation resistance using a megohmmeter to ensure it is above the minimum value.
Perform a polarity test to ensu...
To check motor conditions, perform visual inspection, measure voltage and current, check for abnormal noises, and test motor performance.
Perform a visual inspection to check for any physical damage or loose connections.
Measure the voltage and current using a multimeter to ensure they are within the specified range.
Listen for any abnormal noises such as grinding or squealing that may indicate motor issues.
Test the motor...
VFD drives are used to control the speed and torque of electric motors, resulting in energy savings and improved motor performance.
VFD drives allow for precise control of motor speed and torque.
They can be used to match the motor speed to the load requirements, resulting in energy savings.
VFD drives can improve motor performance by reducing mechanical stress and wear.
They enable soft starting and stopping of motors, re...
ACB and VCB breakers are both types of circuit breakers used in electrical systems, but they differ in their operating mechanisms.
ACB stands for Air Circuit Breaker, while VCB stands for Vacuum Circuit Breaker.
ACB breakers use air as the medium for arc extinction, while VCB breakers use vacuum.
ACB breakers are typically used for low voltage applications, while VCB breakers are used for medium to high voltage applicatio...
Di and Do are electrical protection devices used in low voltage systems to protect against overcurrent and short circuits.
Di stands for Differential Current Protection and is used to detect and protect against ground faults and leakage currents.
Do stands for Overcurrent Protection and is used to protect against overloads and short circuits.
Di works by comparing the current flowing in the live and neutral conductors, an...
based on 2 reviews
Rating in categories
Deputy Manager
1.2k
salaries
| ₹4.5 L/yr - ₹14.3 L/yr |
Senior Manager
651
salaries
| ₹8.5 L/yr - ₹28 L/yr |
Manager
650
salaries
| ₹6.4 L/yr - ₹19 L/yr |
Assistant Manager
315
salaries
| ₹3.8 L/yr - ₹11 L/yr |
Deputy General Manager
314
salaries
| ₹15 L/yr - ₹41 L/yr |
Siemens
ABB
Honeywell Automation
Emerson Electric Co.