Filter interviews by
I applied via Recruitment Consultant and was interviewed before Sep 2020. There were 3 interview rounds.
Top trending discussions
posted on 5 Jul 2020
I appeared for an interview before Jul 2019.
posted on 11 Mar 2022
I applied via Approached by Company and was interviewed before Mar 2021. There were 2 interview rounds.
CB operation and use refers to the operation and use of circuit breakers in electrical systems.
CBs are used to protect electrical systems from overloads and short circuits.
They work by interrupting the flow of current when a fault is detected.
CBs can be manually or automatically operated.
They come in different types, such as air, oil, vacuum, and SF6 CBs.
CBs are commonly used in residential, commercial, and industrial
posted on 19 Apr 2022
I applied via LinkedIn and was interviewed before Apr 2021. There were 2 interview rounds.
I am a dedicated Safety Officer with a strong background in ensuring workplace safety and implementing safety protocols.
Experienced in conducting safety inspections and risk assessments.
Proficient in developing and implementing safety training programs.
Skilled in investigating accidents and incidents to identify root causes and prevent future occurrences.
Knowledgeable in maintaining safety records and ensuring complian...
posted on 2 Nov 2021
I applied via Referral and was interviewed before Nov 2020. There was 1 interview round.
Height work safety involves implementing control measures to prevent falls and injuries.
Conducting a risk assessment before starting any work at height
Providing appropriate training and equipment for workers
Implementing a fall protection plan
Regularly inspecting equipment and ensuring it is in good condition
Establishing clear communication and emergency procedures
Examples of control measures include guardrails, safety ...
posted on 2 Nov 2021
I applied via Referral and was interviewed before Nov 2020. There was 1 interview round.
Single phase and three phase are two types of electrical power distribution systems.
Single phase has one live conductor and one neutral conductor, while three phase has three live conductors and one neutral conductor.
Single phase is commonly used in residential and small commercial applications, while three phase is used in industrial and large commercial applications.
Single phase power supply is suitable for low power...
R, Y, B phases are the three phases of AC power supply. They differ in their phase angle and voltage level.
R phase has a phase angle of 0 degrees and is usually connected to the red wire.
Y phase has a phase angle of 120 degrees and is usually connected to the yellow wire.
B phase has a phase angle of 240 degrees and is usually connected to the blue wire.
The voltage level of each phase is the same, but they are out of ph...
In series, voltage adds up while current remains the same. In parallel, voltage remains the same while current adds up.
In series, batteries are connected end-to-end, positive to negative. In parallel, batteries are connected positive to positive and negative to negative.
Series connection increases voltage but does not increase current. Parallel connection increases current but does not increase voltage.
Series connectio...
Periodic maintenance of batteries is crucial for their longevity and optimal performance.
Check the battery terminals for corrosion and clean them if necessary
Inspect the battery case for any cracks or damage
Ensure that the battery is securely fastened in place
Check the electrolyte level and top up with distilled water if required
Test the battery voltage and recharge if necessary
A faulty battery can be identified by checking its voltage, capacity, and physical appearance.
Check the voltage of the battery using a multimeter
Test the capacity of the battery using a battery tester
Inspect the physical appearance of the battery for any signs of damage or leakage
Check the battery terminals for corrosion or loose connections
Compare the battery's performance to its specifications
FUSE, MCB, ELCB, and RCCB are all electrical protection devices, but they differ in their functions and applications.
FUSE is a simple device that protects electrical circuits from overloading or short-circuiting by melting and breaking the circuit.
MCB (Miniature Circuit Breaker) is an automatic switch that trips and cuts off the power supply when there is an overload or short-circuit.
ELCB (Earth Leakage Circuit Breaker...
A DOL starter is a direct online motor starter that provides full voltage to the motor.
Consists of a contactor, overload relay, and start/stop buttons
The contactor connects the motor to the power supply
The overload relay protects the motor from overloading
The start/stop buttons control the on/off function of the motor
Used for small motors with low starting current
Not suitable for large motors or motors with high starti
posted on 26 Dec 2021
I applied via Walk-in and was interviewed in Nov 2021. There was 1 interview round.
HIRA stands for Hazard Identification and Risk Assessment.
HIRA is a systematic process of identifying potential hazards and analyzing the associated risks.
It involves identifying the hazards, assessing the risks, and implementing control measures to mitigate the risks.
HIRA is an important tool for safety officers to ensure the safety of employees and the workplace.
Examples of hazards that can be identified through HIRA...
I'm sorry, but the question is not clear and seems to be incomplete.
Please provide more context or rephrase the question.
Without proper information, I cannot provide a relevant answer.
Kindly clarify the question so that I can assist you better.
LMR full from refers to a situation where the Land Mobile Radio system is at maximum capacity.
LMR full from means that the Land Mobile Radio system is unable to accommodate any more users or communications.
This can occur when all available channels or frequencies are in use.
It may result in communication delays or the inability to establish new connections.
LMR full from can impact the effectiveness of emergency respons...
Safety is the state of being protected from harm, danger, or injury.
Safety involves identifying and assessing potential hazards
It requires implementing measures to prevent or mitigate those hazards
It involves training and educating individuals on safe practices
Safety is a continuous process that requires ongoing evaluation and improvement
Examples of safety measures include wearing personal protective equipment, followi...
Shutting down work is a crucial safety measure to prevent accidents and ensure the well-being of workers.
Shutting down work may be necessary in case of an imminent danger or hazard that cannot be immediately controlled.
It is important to have clear protocols and procedures in place for shutting down work in different scenarios.
Examples of situations that may require work shutdown include gas leaks, chemical spills, str...
An accident is an unexpected and unintentional event that causes harm or damage.
Accidents can happen in any setting, including workplaces, homes, and on the road.
They can result in physical injuries, property damage, or both.
Accidents can be caused by human error, equipment failure, or environmental factors.
Examples of accidents include slips and falls, car crashes, and machinery malfunctions.
An incident is an unplanned event that results in injury, damage, or loss.
Incidents can occur in any workplace or environment
They can range from minor incidents such as slips and falls to major incidents such as explosions or fires
Incidents should be reported and investigated to prevent future occurrences
Proper safety measures and training can help prevent incidents from happening
posted on 30 May 2022
I applied via Naukri.com and was interviewed in Apr 2022. There were 4 interview rounds.
How to implement workers to do work in a Safety process.
How to minimize and control hazard.
I applied via Recruitment Consulltant and was interviewed in Nov 2023. There were 4 interview rounds.
HSE policy, Hira, jsa, bocw
HSE Officer
52
salaries
| ₹5 L/yr - ₹18.5 L/yr |
Mechanical Supervisor
47
salaries
| ₹4.2 L/yr - ₹13.2 L/yr |
Safety Officer
37
salaries
| ₹3 L/yr - ₹12 L/yr |
Mechanical Technician
37
salaries
| ₹3.5 L/yr - ₹10.1 L/yr |
Mechanical Engineer
29
salaries
| ₹6.3 L/yr - ₹9.8 L/yr |
Shapoorji Pallonji Group
Kalpataru Projects International
Nagarjuna Construction Company
KEC International