10+ FedEx Express Interview Questions and Answers

Updated 20 Feb 2025

Q1. What are the current setting parameters for relays, and how do you select contactors and cables for a feeder?

Ans.

Relay setting parameters include current rating, time delay, and pickup voltage. Contactors and cables for a feeder are selected based on load current, voltage rating, and environmental conditions.

  • Relay setting parameters include current rating, time delay, and pickup voltage

  • Contactors for a feeder are selected based on load current and voltage rating

  • Cables for a feeder are selected based on load current, voltage rating, and environmental conditions

Add your answer

Q2. What is the process for setting up a multiple function relay?

Ans.

Setting up a multiple function relay involves configuring the relay settings, connecting it to the power source and load, and testing its functionality.

  • Configure the relay settings based on the specific functions required, such as overcurrent protection, voltage monitoring, or phase sequence detection.

  • Connect the relay to the power source and load using appropriate wiring and terminals.

  • Test the relay's functionality by simulating different fault conditions and verifying that ...read more

Add your answer

Q3. What are the maintenance procedures for low tension (LT) and high tension (HT) motors?

Ans.

Maintenance procedures for LT and HT motors involve regular inspection, cleaning, lubrication, and testing.

  • Regularly inspect motor for any signs of wear or damage

  • Clean motor components to prevent dust and debris buildup

  • Lubricate moving parts as per manufacturer's recommendations

  • Test motor performance using appropriate tools and equipment

  • Check electrical connections for tightness and signs of overheating

  • Monitor motor temperature during operation

  • Keep motor surroundings clean an...read more

Add your answer

Q4. What are the parameters for setting Variable Voltage and Frequency Drives (VVFD)?

Ans.

Parameters for setting Variable Voltage and Frequency Drives (VVFD) include voltage, frequency, acceleration time, deceleration time, and motor overload protection.

  • Voltage setting determines the output voltage supplied to the motor.

  • Frequency setting controls the speed of the motor.

  • Acceleration time sets the time taken for the motor to reach full speed from standstill.

  • Deceleration time determines how quickly the motor slows down.

  • Motor overload protection is important to preven...read more

Add your answer
Discover FedEx Express interview dos and don'ts from real experiences

Q5. Which model of PLC have you worked with, and what can you tell me about inter-node communication?

Ans.

I have worked with Allen-Bradley PLCs and have experience with inter-node communication.

  • I have experience working with Allen-Bradley PLCs, specifically the ControlLogix series.

  • Inter-node communication refers to the exchange of data between different nodes or devices within a PLC network.

  • This communication can be achieved using various protocols such as Ethernet/IP, DeviceNet, or ControlNet.

  • Examples of inter-node communication include sending data between PLCs in a production ...read more

Add your answer

Q6. What are the maintenance procedures for an OLTC transformer?

Ans.

Maintenance procedures for an OLTC transformer involve regular inspection, cleaning, lubrication, and testing.

  • Regularly inspect the OLTC for any signs of wear, damage, or overheating.

  • Clean the OLTC contacts and components to ensure proper functioning.

  • Lubricate moving parts to prevent friction and wear.

  • Perform routine testing to check the OLTC's operation and efficiency.

  • Keep detailed records of maintenance activities and any issues encountered.

  • Consult manufacturer guidelines f...read more

Add your answer
Are these interview questions helpful?

Q7. How to check pi value of transformer,how to maintenance of ht and lt motors,

Ans.

To check pi value of transformer, perform insulation resistance test. For maintenance of HT and LT motors, follow manufacturer's guidelines.

  • To check pi value of transformer, perform insulation resistance test using a megger.

  • For maintenance of HT and LT motors, follow manufacturer's guidelines regarding lubrication, cleaning, and inspection.

  • Regularly check for any abnormal noise, vibration, or temperature rise in motors.

  • Ensure proper ventilation and cooling of motors.

  • Check and...read more

Add your answer

Q8. How to handle man power if not follow your instructions

Ans.

Communicate clearly and set expectations, provide training and support, and take corrective action if necessary.

  • Clearly communicate expectations and consequences of not following instructions

  • Provide training and support to ensure understanding and competence

  • Take corrective action if necessary, including disciplinary measures

  • Document incidents and follow up with individuals to prevent future occurrences

Add your answer
Share interview questions and help millions of jobseekers 🌟

Q9. What size of furnace you have handled?

Ans.

I have handled furnaces ranging from small residential units to large industrial furnaces.

  • Handled various sizes of furnaces including residential, commercial, and industrial

  • Experience with troubleshooting and maintenance of different furnace sizes

  • Managed installation and repair of furnaces of different capacities

Add your answer

Q10. What is positive isolation?

Ans.

Positive isolation is a safety procedure that involves isolating a system or equipment from its energy source to prevent accidental activation.

  • Positive isolation is a critical safety measure that ensures the safety of workers and equipment.

  • It involves disconnecting a system or equipment from its energy source, such as electricity, gas, or steam.

  • Positive isolation is typically done using lockout/tagout procedures, which involve locking and tagging the energy source to prevent ...read more

Add your answer

Q11. Types of rotary equupments

Ans.

Rotary equipment refers to machines that rotate around a central axis.

  • Pumps (centrifugal, positive displacement)

  • Compressors (centrifugal, reciprocating, screw)

  • Turbines (steam, gas, hydraulic)

  • Mixers (agitators, blenders)

  • Fans (centrifugal, axial)

  • Rollers (conveyor, printing)

  • Generators (diesel, gas, wind)

  • Extruders (single screw, twin screw)

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos

Interview Process at FedEx Express

based on 5 interviews
Interview experience
4.2
Good
View more
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories

Top Interview Questions from Similar Companies

3.8
 • 331 Interview Questions
4.1
 • 299 Interview Questions
4.0
 • 281 Interview Questions
3.4
 • 174 Interview Questions
4.1
 • 156 Interview Questions
4.1
 • 140 Interview Questions
View all
Top Pradhan Associates Interview Questions And Answers
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter