I applied via Company Website and was interviewed before Nov 2020. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Aug 2020. There were 3 interview rounds.
Power factor is a measure of how effectively electrical power is being used in a circuit.
Power factor is the ratio of real power (in watts) to apparent power (in volt-amperes).
It indicates the efficiency of electrical power consumption in a circuit.
A power factor of 1 means all the power is being used effectively, while a power factor less than 1 indicates wastage of power.
Inductive loads like motors and transformers h...
A motor is an electrical device that converts electrical energy into mechanical energy.
Motors are used in a variety of applications, from powering industrial machinery to driving household appliances.
There are different types of motors, including AC motors, DC motors, and stepper motors.
Motors can be controlled using various methods, such as variable frequency drives and soft starters.
Proper maintenance and inspection ...
A star delta starter is used to reduce the starting current of a motor.
The motor is initially connected in star configuration to reduce the voltage across each winding.
After a set time, the motor is switched to delta configuration for normal operation.
The control diagram includes a timer, contactors, and overload protection.
The timer delays the switching from star to delta configuration.
The contactors are used to switc...
DOL starter is used in single-phase induction motors and small three-phase motors.
DOL starter stands for Direct-On-Line starter.
It is used to start and stop the motor directly without any intermediate control.
It is commonly used in single-phase induction motors and small three-phase motors.
DOL starter provides full voltage to the motor during starting, which can cause high starting current.
It consists of a contactor, t...
The resistive load equation is used to calculate the power consumed by a resistive load.
The equation is P = V^2/R, where P is power, V is voltage, and R is resistance.
This equation is used in electrical engineering to determine the power consumption of resistive loads such as heaters and incandescent light bulbs.
The equation can also be rearranged to solve for voltage or resistance, depending on the information given.
I...
Asynchronous motors are used for various purposes due to their simple design and low cost.
Asynchronous motors are commonly used in industrial applications such as pumps, fans, and compressors.
They are also used in household appliances like washing machines and refrigerators.
Asynchronous motors are preferred for their low maintenance and high reliability.
They are also used in electric vehicles and hybrid cars.
Asynchrono...
Transformers are classified based on their construction, purpose, and voltage level.
Based on construction: core type, shell type, and Berry type
Based on purpose: power transformer, distribution transformer, isolation transformer, autotransformer, etc.
Based on voltage level: step-up transformer, step-down transformer, and isolation transformer
Other classifications: single-phase transformer, three-phase transformer, and ...
India has a total installed capacity of over 370 GW as of 2021.
India's power generation capacity has been growing rapidly in recent years
The country has set a target of achieving 450 GW of renewable energy capacity by 2030
India is one of the world's largest producers of renewable energy, with a capacity of over 100 GW
Coal still accounts for a significant portion of India's power generation, but the government is workin
Chopper circuits are used to convert a fixed DC voltage to a variable DC voltage.
Chopper circuits are also known as DC-DC converters.
They are used in applications such as battery charging, motor control, and renewable energy systems.
Chopper circuits use high-frequency switching to control the output voltage.
Examples of chopper circuits include buck converters, boost converters, and buck-boost converters.
I applied via Company Website and was interviewed before Apr 2020. There were 3 interview rounds.
posted on 27 Dec 2024
Notice period is the amount of time an employee needs to give before leaving a job.
Notice period is typically stated in the employment contract.
It can range from 1 week to several months depending on the company and position.
During the notice period, the employee is expected to work as usual and hand over responsibilities.
Some companies may allow employees to buy out their notice period by paying a fee.
Notice period pr...
I was interviewed in Feb 2022.
I applied via Company Website
I applied via Referral
I applied via Company Website and was interviewed before Oct 2021. There were 3 interview rounds.
Concrete temperature refers to the temperature of freshly mixed concrete.
Concrete temperature affects the setting time and strength development of concrete.
It is important to control the temperature of concrete during mixing, transportation, and placement.
High temperatures can accelerate the setting time and reduce workability, while low temperatures can slow down setting and strength gain.
Concrete temperature is typic...
Precocious of water structure joint refers to the ability of a joint to withstand water pressure and prevent leakage.
Water structure joints should be designed and constructed to be watertight.
Various types of joints can be used in water structures, such as expansion joints, construction joints, and control joints.
Proper sealing materials and techniques should be employed to ensure the integrity of the joints.
Regular in...
Cube test results are used to determine the compressive strength of concrete at 7 and 28 days.
Cube test involves casting cubes of concrete and testing them under compression
Results are reported in terms of compressive strength in MPa or psi
7-day results are used to determine early strength and 28-day results are used to determine ultimate strength
Concrete with a compressive strength of at least 20 MPa is considered sui
Service Engineer
11
salaries
| ₹0 L/yr - ₹0 L/yr |
Cluster Leader
9
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
8
salaries
| ₹0 L/yr - ₹0 L/yr |
MIS Coordinator
6
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior HR Executive
6
salaries
| ₹0 L/yr - ₹0 L/yr |
Kirloskar Electric Company
BHEL
Thermax Limited
Crompton Greaves Consumer Electricals