Filter interviews by
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
Current is the flow of electric charge in a circuit.
Current is measured in amperes (A).
It is caused by the movement of electrons or other charged particles.
Current can be either direct current (DC) or alternating current (AC).
In a DC circuit, current flows in one direction only, while in an AC circuit, it periodically changes direction.
Current is essential for the operation of electrical devices and is controlled by re
An amp is a unit of electric current measurement in the International System of Units (SI).
Amp is short for ampere, named after the French physicist André-Marie Ampère.
It is used to measure the flow of electric charge in a circuit.
One ampere is defined as the amount of current that flows through a conductor when a potential difference of one volt is applied across it.
Amps are commonly used to rate the capacity of elect...
Top trending discussions
I applied via Campus Placement and was interviewed before Aug 2021. There were 4 interview rounds.
30 questions related aptitude and core branch.
4 or 5 panel members are sitting in front of me and asked question one by one
I applied via Approached by Company and was interviewed before Oct 2021. There were 3 interview rounds.
COP of a chiller stands for Coefficient of Performance, which is a measure of the efficiency of a chiller system.
COP is calculated as the ratio of cooling output to the energy input required to produce that cooling output.
A higher COP value indicates a more efficient chiller system.
COP can be calculated using the formula: COP = Cooling Output / Energy Input.
For example, if a chiller has a COP of 4, it means that for ev...
I applied via Naukri.com and was interviewed in Dec 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed before Mar 2022. There were 4 interview rounds.
Elementry mathematics questions
There are two types of projection in technical drawings: orthographic and isometric.
Orthographic projection shows the object as it appears from different directions.
Isometric projection shows the object in a 3D view with equal angles between the axes.
Orthographic projection is commonly used in engineering drawings.
Isometric projection is commonly used in architectural and product design drawings.
Evaporator is a heat exchanger that converts liquid into vapor by absorbing heat from the surroundings.
Evaporator is a key component in refrigeration and air conditioning systems.
It operates at low temperatures to absorb heat from the surroundings and convert liquid refrigerant into vapor.
The temperature of the evaporator is typically lower than the surrounding environment to facilitate heat transfer.
The heat absorbed ...
Condenser, compressor, and evaporator are key components in a refrigeration system.
Condenser: Converts refrigerant gas into liquid by releasing heat to the surroundings.
Compressor: Increases the pressure and temperature of the refrigerant gas.
Evaporator: Absorbs heat from the surroundings to evaporate the refrigerant into a gas.
Example: In an air conditioning unit, the condenser is located outside to release heat, the ...
Safety is the practice of preventing accidents, injuries, and other potential hazards in the workplace.
Always wear appropriate personal protective equipment (PPE)
Follow safety protocols and procedures
Keep work areas clean and organized
Report any unsafe conditions or incidents to supervisors
Attend safety training sessions regularly
Kaizen is a Japanese term meaning continuous improvement. 7QC Tools are a set of quality control tools. GD&T stands for Geometric Dimensioning and Tolerancing. Tolerance refers to the allowable variation in a dimension. The symbol of concentricity is a circle within a circle.
Kaizen is a philosophy of continuous improvement in all aspects of life and work.
7QC Tools are a set of problem-solving tools used in quality cont...
I applied via Recruitment Consulltant and was interviewed in Jul 2022. There were 2 interview rounds.
About of HVAC system
There are many questions regarding reseating and Apitube.
Rendering API responses in the frontend.
Assistant Manager
47
salaries
| ₹10.6 L/yr - ₹21 L/yr |
Senior Application Engineer
23
salaries
| ₹7.5 L/yr - ₹16.5 L/yr |
Senior Sales Engineer
22
salaries
| ₹8 L/yr - ₹13.6 L/yr |
Assistant Sales Manager
20
salaries
| ₹11.5 L/yr - ₹19.5 L/yr |
Senior Engineer
15
salaries
| ₹6.5 L/yr - ₹15 L/yr |
Dell
HARMAN
Godrej & Boyce Manufacturing
Vivo