Lakshya Powertech Limited Field Engineer Interview Questions and Answers for Experienced

Updated 12 Sep 2020

Lakshya Powertech Limited Field Engineer Interview Experiences for Experienced

1 interview found

I applied via Referral and was interviewed before Sep 2019. There were 3 interview rounds.

Interview Questionnaire 

3 Questions

  • Q1. They asked all about from my experience.
  • Q2. Management skills
  • Q3. Any task apart from your experience
  • Ans. 

    I have experience in troubleshooting network issues and configuring network devices.

    • Troubleshooting network connectivity problems

    • Configuring routers and switches

    • Installing and maintaining network equipment

    • Performing network audits and assessments

    • Implementing network security measures

  • Answered by AI

Interview Preparation Tips

Interview preparation tips for other job seekers - If you are experienced then be confident and explain about your experience positively. Don't try to bypass small things of routine jobs. Let them know about your personality, it will help you.

Interview questions from similar companies

Interview Questionnaire 

1 Question

  • Q1. Normal question about personality and job related

Interview Preparation Tips

Round: Test
Experience: Interview was going smoothly & all questions was related my job so it's was easy for me.
Tips: Good knowledge about of wind turbine
Duration: 2 hours
Total Questions: 25

Round: HR Interview
Experience: Interview was completed so easy
Tips: Required nice personality and confidence is must required

I was interviewed before Nov 2016.

Interview Questionnaire 

3 Questions

  • Q1. About yourself
  • Q2. Will you work at any location
  • Ans. 

    Yes, I am willing to work at any location for the Senior Engineer position.

    • I am open to relocating for the right opportunity

    • I have experience working in different locations

    • I am flexible and adaptable to new environments

  • Answered by AI
  • Q3. Why you think you can work in any adverse situation
  • Ans. 

    I have a proven track record of staying calm and focused in challenging situations, allowing me to problem-solve effectively.

    • I have experience working in high-pressure environments and have successfully delivered projects on time despite obstacles.

    • I am adaptable and can quickly assess a situation to determine the best course of action.

    • I have strong problem-solving skills and can think creatively to find solutions in ad

  • Answered by AI

Interview Preparation Tips

Round: Test
Duration: 1 hour
Total Questions: 100

Round: Group Discussion
Duration: 20 minutes

I applied via Referral and was interviewed before Apr 2021. There was 1 interview round.

Round 1 - Technical 

(1 Question)

  • Q1. Maintenance phylosophy
  • Ans. Depends on equipment running hour, criticality, availability and standby.
  • Answered Anonymously

Interview Preparation Tips

Topics to prepare for Thermax Limited Senior Engineer interview:
  • Boe
  • Energy manager
Interview preparation tips for other job seekers - Be confidential and technically strong.

I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.

Interview Questionnaire 

10 Questions

  • Q1. Why transformer are rated in KVA.
  • Ans. 

    Transformers are rated in KVA because it represents the apparent power they can handle.

    • KVA stands for kilovolt-ampere, which is a unit of apparent power.

    • Transformers are designed to handle a certain amount of power, and the KVA rating indicates their capacity.

    • The KVA rating takes into account both the voltage and current that the transformer can handle.

    • It helps in determining the appropriate size and capacity of the tr...

  • Answered by AI
  • Q2. What is the ground clearance of 400KV transmission line.
  • Ans. 

    The ground clearance of a 400KV transmission line varies depending on various factors.

    • The ground clearance of a transmission line is the vertical distance between the lowest point of the conductor and the ground.

    • The ground clearance is determined based on safety regulations and requirements.

    • Factors that influence the ground clearance include terrain, vegetation, and proximity to buildings or roads.

    • In hilly areas, the g...

  • Answered by AI
  • Q3. What should be the tan Delta value of electrical equipment (for example T/F).
  • Ans. 

    The tan Delta value of electrical equipment should be as low as possible.

    • Tan Delta is a measure of the dielectric losses in electrical equipment.

    • A low tan Delta value indicates that the equipment has good insulation properties.

    • The tan Delta value can be affected by factors such as temperature, moisture, and aging of the equipment.

    • For transformers, a typical tan Delta value is around 0.001 or lower.

  • Answered by AI
  • Q4. Why ACSRinvar conductor are widely used in metro principal city.
  • Ans. 

    ACSRinvar conductors are widely used in metro principal cities due to their high strength and low thermal expansion.

    • ACSRinvar conductors have a high tensile strength, making them suitable for long-distance transmission lines in metro cities.

    • They have a low coefficient of thermal expansion, which helps in reducing sagging of the conductors and maintaining power transmission efficiency.

    • The use of ACSRinvar conductors in ...

  • Answered by AI
  • Q5. The Basis setting of REF protectionfor transformer should be how much.
  • Ans. 

    The Basis setting of REF protection for a transformer should be determined based on the transformer's characteristics and the system requirements.

    • The basis setting of REF (Restricted Earth Fault) protection for a transformer is typically determined by considering the transformer's winding configuration, impedance, and the system's fault level.

    • The setting should be chosen to ensure that the protection operates reliably ...

  • Answered by AI
  • Q6. The SF6 gas used for Ckt breaker chamber should be how much bar.
  • Ans. 

    The SF6 gas used for Ckt breaker chamber should be maintained at a pressure of around 5-7 bar.

    • The SF6 gas in the circuit breaker chamber should be maintained at a specific pressure to ensure proper functioning.

    • The recommended pressure for SF6 gas in the circuit breaker chamber is typically between 5 and 7 bar.

    • Maintaining the correct pressure helps in extinguishing the arc during circuit interruption.

    • Too low or too high...

  • Answered by AI
  • Q7. Why star star zero phase shift transformer winding are used.
  • Ans. 

    Star-star zero phase shift transformer windings are used to provide a balanced three-phase output with zero phase shift between primary and secondary voltages.

    • Star-star zero phase shift transformer windings are commonly used in power distribution systems.

    • They are used to supply power to three-phase loads such as motors, generators, and transformers.

    • The windings are designed in such a way that the voltages in the primar...

  • Answered by AI
  • Q8. What are the main difference between AIS and GIS Substation.
  • Ans. 

    AIS and GIS substations differ in their construction and insulation methods.

    • AIS (Air Insulated Substation) uses air as the insulation medium, while GIS (Gas Insulated Substation) uses SF6 gas.

    • AIS substations require larger land areas compared to GIS substations.

    • GIS substations are more compact and can be installed in urban areas where space is limited.

    • AIS substations are more susceptible to environmental factors like p...

  • Answered by AI
  • Q9. Why vibration damper are used with Conductor.
  • Ans. 

    Vibration dampers are used with conductors to reduce the risk of fatigue failure and damage caused by wind-induced vibrations.

    • Vibration dampers absorb and dissipate the energy generated by wind-induced vibrations in conductors.

    • They help to reduce the risk of fatigue failure and damage to the conductor and associated hardware.

    • Vibration dampers are typically installed at regular intervals along the length of the conducto...

  • Answered by AI
  • Q10. What is main function of LA in Substion.
  • Ans. 

    The main function of LA in a substation is to protect electrical equipment from lightning strikes.

    • LA stands for Lightning Arrester.

    • It is installed in substations to divert lightning strikes away from sensitive equipment.

    • LA provides a low-impedance path for lightning current to flow to the ground.

    • It helps in preventing damage to transformers, circuit breakers, and other electrical devices.

    • LA operates by ionizing the air...

  • Answered by AI

Interview Preparation Tips

Interview preparation tips for other job seekers - As per my point of view the interview for Electrical Experience Engineer/Manager should be on behalf of Experience and technical topics.
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
6-8 weeks
Result
Selected Selected

I applied via Approached by Company

Round 1 - Technical 

(1 Question)

  • Q1. Transformer working Principal
  • Ans. 

    Transformer works on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.

    • Transformers have two coils of wire, known as primary and secondary coils.

    • When an alternating current flows through the primary coil, it creates a changing magnetic field.

    • This changing magnetic field induces a voltage in the secondary coil, transferring electrical energy.

    • Transformers are used to st...

  • Answered by AI
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Round 1 - Technical 

(1 Question)

  • Q1. Transmission and distribution realted question
Round 1 - Technical 

(2 Questions)

  • Q1. What's your ambition
  • Q2. What's your goals why you want to go for it

Interview Preparation Tips

Interview preparation tips for other job seekers - Not bad. Better to go for other companies where the job is secure and had good leadership.
Not good for FTE
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Round 1 - Resume Shortlist 
Pro Tip by AmbitionBox:
Keep your resume crisp and to the point. A recruiter looks at your resume for an average of 6 seconds, make sure to leave the best impression.
View all tips
Round 2 - Aptitude Test 

CBT at designated venue as fixed by PGCIL and will be mentioned in the admit card.

Round 3 - Technical 

(2 Questions)

  • Q1. Basic Electrical Engineering, Power Transmission and Distribution Networks, various equipments used in Power Systems, HR Question etc.
  • Q2. What are the various types of conductors and details?
  • Ans. 

    Various types of conductors include copper, aluminum, and steel.

    • Copper: highly conductive, commonly used in electrical wiring

    • Aluminum: lighter and cheaper than copper, used in power lines

    • Steel: used in overhead transmission lines for strength and durability

  • Answered by AI
Interview experience
4
Good
Difficulty level
-
Process Duration
-
Result
-
Round 1 - Group Discussion 

Discuss work related questions

Round 2 - HR 

(1 Question)

  • Q1. Salary discuss and other accommodation

Interview Preparation Tips

Interview preparation tips for other job seekers - Good for career growth and life cycle balance

Tell us how to improve this page.

Interview Questions from Similar Companies

Senco Gold Interview Questions
4.5
 • 558 Interviews
Swiggy Interview Questions
3.8
 • 428 Interviews
Siemens Interview Questions
4.1
 • 420 Interviews
Planet Spark Interview Questions
3.7
 • 360 Interviews
ITC Infotech Interview Questions
3.6
 • 335 Interviews
Udaan Interview Questions
4.0
 • 334 Interviews
Meesho Interview Questions
3.7
 • 328 Interviews
Ekart Logistics Interview Questions
3.9
 • 307 Interviews
CitiusTech Interview Questions
3.4
 • 270 Interviews
NeoSOFT Interview Questions
3.6
 • 262 Interviews
View all
Lakshya Powertech Limited Field Engineer Salary
based on 5 salaries
₹3.2 L/yr - ₹3.9 L/yr
10% less than the average Field Engineer Salary in India
View more details

Lakshya Powertech Limited Field Engineer Reviews and Ratings

based on 1 review

3.0/5

Rating in categories

3.0

Skill development

3.0

Work-life balance

2.0

Salary

1.0

Job security

3.0

Company culture

2.0

Promotions

2.0

Work satisfaction

Explore 1 Review and Rating
Mechanical Technician
22 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Mechanical Engineer
13 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Civil Engineer
7 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Process Engineer
7 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Project Manager
7 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Explore more salaries
Compare Lakshya Powertech Limited with

Suzlon Group

4.1
Compare

BHEL

4.1
Compare

Tata Power

3.9
Compare

Adani Power

3.9
Compare
Did you find this page helpful?
Yes No
write
Share an Interview