Q1. What are different maintenance procedures,How can one ensure for zero breakdown for equipments.

Ans.

Regular maintenance, inspections, and repairs can prevent equipment breakdowns.

  • Develop a preventive maintenance schedule

  • Train staff on proper equipment use and care

  • Regularly inspect equipment for signs of wear and tear

  • Address any issues promptly to prevent further damage

  • Keep accurate records of maintenance and repairs

  • Consider investing in newer, more reliable equipment

  • Partner with reputable vendors for repairs and replacements

View 1 answer

Q2. Which type of redundancy should be available for Data center in terms of infrastructure.

Ans.

Data centers should have N+1 or 2N redundancy for infrastructure.

  • N+1 redundancy means having one extra backup component for every critical component in the infrastructure.

  • 2N redundancy means having two complete sets of infrastructure, each capable of handling the full load, with one set acting as a backup for the other.

  • Redundancy ensures high availability and minimizes downtime in case of component failure.

  • Examples of critical components that require redundancy include power ...read more

Add your answer

Q3. How do you manage incidents and Risks of Site's?

Ans.

I manage incidents and risks of sites by implementing a comprehensive risk management plan.

  • Conducting regular risk assessments to identify potential hazards

  • Developing and implementing emergency response plans

  • Training staff on safety procedures and protocols

  • Maintaining accurate incident records and conducting thorough investigations

  • Collaborating with external agencies and stakeholders

  • Regularly reviewing and updating risk management plans

Add your answer

Q4. How many types of energy convertion are there in DG set

Ans.

There are two main types of energy conversion in a DG set: mechanical energy to electrical energy and chemical energy to mechanical energy.

  • Mechanical energy to electrical energy: The diesel engine in the DG set converts the mechanical energy produced by the combustion of diesel fuel into electrical energy through the alternator.

  • Chemical energy to mechanical energy: The combustion of diesel fuel in the engine generates heat energy, which is then converted into mechanical energ...read more

View 1 answer
Discover The Laburnum interview dos and don'ts from real experiences

Q5. What is the importance of transformer oil

Ans.

Transformer oil is crucial for insulating and cooling transformers to ensure efficient operation and prevent breakdowns.

  • Transformer oil acts as an insulating medium to prevent electrical breakdowns

  • It also helps in cooling the transformer by dissipating heat generated during operation

  • Regular testing and maintenance of transformer oil is essential to ensure its effectiveness

  • Contaminated or degraded transformer oil can lead to equipment failure and costly repairs

  • Examples of tran...read more

View 2 more answers

Q6. If DG set trips when taking on load, reasons

Ans.

DG set trips when taking on load due to various reasons such as overload, short circuit, fuel issues, or mechanical failures.

  • Overload on the DG set causing it to trip for safety reasons

  • Short circuit in the electrical system leading to a trip

  • Fuel supply issues such as low fuel level or contaminated fuel

  • Mechanical failures in the DG set components

  • Incorrect load balancing causing the DG set to trip

Add your answer
Are these interview questions helpful?

Q7. What will be reason of dg doesnt crank

Ans.

Possible reasons for a DG not cranking include dead battery, faulty starter motor, fuel supply issues, or electrical problems.

  • Dead battery: Check the battery voltage and connections.

  • Faulty starter motor: Test the starter motor for proper functioning.

  • Fuel supply issues: Ensure there is enough fuel in the tank and check the fuel lines for blockages.

  • Electrical problems: Inspect the wiring and fuses for any damage or faults.

View 1 answer

Q8. what is the activity of WTP

Ans.

WTP stands for Water Treatment Plant, which is responsible for treating water to make it safe for consumption.

  • WTP is responsible for removing impurities and contaminants from water.

  • It involves processes such as filtration, sedimentation, and disinfection.

  • Examples of WTPs include municipal water treatment plants and industrial water treatment facilities.

Add your answer
Share interview questions and help millions of jobseekers 🌟

Q9. What is the activity of STP

Ans.

STP stands for Sewage Treatment Plant, which is responsible for treating wastewater to remove contaminants before releasing it back into the environment.

  • STP is a facility designed to treat wastewater from households, industries, and commercial buildings.

  • The process involves physical, chemical, and biological methods to remove contaminants such as solids, organic matter, and pathogens.

  • Common treatment methods in STP include screening, sedimentation, biological treatment (such ...read more

Add your answer

Q10. How you calculated CAM charge.

Ans.

CAM charge is calculated by dividing the total operating expenses of a property by the total square footage of the property.

  • Total operating expenses include costs such as property taxes, insurance, maintenance, and utilities.

  • Divide the total operating expenses by the total square footage of the property to get the CAM charge per square foot.

  • For example, if the total operating expenses are $100,000 and the total square footage is 10,000, the CAM charge per square foot would be...read more

Add your answer

Q11. UPS diagram and its parts

Ans.

A UPS diagram shows the components of an uninterruptible power supply system.

  • UPS system includes a rectifier, battery, inverter, and bypass switch

  • Rectifier converts AC power to DC power to charge the battery

  • Battery stores energy to provide power during outages

  • Inverter converts DC power from the battery to AC power for devices

  • Bypass switch allows power to bypass the UPS during maintenance or failure

View 1 answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos

Interview Process at The Laburnum

based on 11 interviews
2 Interview rounds
Resume Shortlist Round
One-on-one Round
View more
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories

Top Facility Manager Interview Questions from Similar Companies

3.4
 • 13 Interview Questions
View all
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
75 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter