Intertek
20+ Anthelio Healthcare Solutions Interview Questions and Answers
Q1. What is depth required fir igl has laying
The depth required for IGL gas laying depends on various factors such as soil type, traffic load, and depth of other utilities.
The depth should be sufficient to prevent damage from external factors such as traffic load and soil type.
The depth should also be deep enough to avoid interference with other utilities.
The depth requirement may vary depending on the location and local regulations.
For example, in Delhi, the minimum depth requirement for IGL gas laying is 1.2 meters.
Th...read more
Q2. Q. What is represented by W,H,R,P and V?
W, H, R, P, and V represent different variables or parameters.
W could represent weight or width
H could represent height
R could represent radius
P could represent pressure
V could represent volume
Q3. In which type of fitting use during charging
Fittings used during charging depend on the type of refrigerant and system design.
The type of refrigerant and system design determine the fittings used during charging.
Common fittings include flare, sweat, and quick-connect fittings.
Flare fittings are commonly used in air conditioning systems.
Sweat fittings are commonly used in refrigeration systems.
Quick-connect fittings are commonly used in automotive air conditioning systems.
Proper fittings must be used to prevent leaks an...read more
Q4. Q. Types of valve and it's function?
Valves are devices used to control the flow of fluids or gases in a system.
Gate valve: used to start or stop the flow of fluid by lifting or lowering a gate
Ball valve: uses a rotating ball with a hole to control the flow
Check valve: allows flow in one direction and prevents backflow
Globe valve: controls flow by raising or lowering a disc against the flow
Butterfly valve: uses a disc to control flow by rotating it
Q5. Q. QAP, WPS and DFT description?
QAP, WPS, and DFT are important documents used in inspection engineering.
QAP stands for Quality Assurance Plan, which outlines the procedures and requirements for ensuring quality in a project or process.
WPS stands for Welding Procedure Specification, which provides detailed instructions for performing welding operations.
DFT stands for Dry Film Thickness, which refers to the thickness of a coating or paint applied to a surface.
QAP ensures that quality standards are met throug...read more
Q6. What is required data for fire & safety
Data required for fire & safety
Building layout and floor plans
Location of fire exits and emergency equipment
Fire suppression systems and equipment
Fire alarm and detection systems
Emergency response plan and procedures
Q7. Types of pipe, what is wps, difference between garade A53 and A106, process of hydrotest and pneometic test, what is ndt, one weldor productivity in one day, one day erection on one day, what is jsa
Types of pipes include steel, copper, PVC; WPS stands for Welding Procedure Specification; A53 is for low pressure, A106 is for high pressure; Hydrotest uses water, pneumatic test uses air; NDT is Non-Destructive Testing; JSA is Job Safety Analysis.
Types of pipes: steel, copper, PVC
WPS: Welding Procedure Specification
Difference between A53 and A106: A53 for low pressure, A106 for high pressure
Process of hydrotest: uses water to test for leaks
Process of pneumatic test: uses ai...read more
Q8. Loading unloading weight quantity and quality
Loading, unloading weight quantity, and quality are important factors in ensuring product integrity.
Loading and unloading processes should be carefully monitored to prevent damage to the products.
Weight verification should be conducted to ensure accurate quantity of goods.
Quality checks should be performed to ensure that the products meet the required standards.
Examples: using weighing scales to measure the weight of goods, inspecting the condition of products during loading ...read more
Q9. Instrument of GC Ms and UV spectroscopy trouble shooting
For GC Ms, check for leaks, column contamination, and detector issues. For UV spectroscopy, check for lamp and cell issues.
For GC Ms, check for leaks in the system and ensure that the column is not contaminated. Also, check for detector issues such as a dirty or faulty detector.
For UV spectroscopy, check for lamp issues such as a burnt-out lamp or incorrect wavelength settings. Also, check for cell issues such as air bubbles or scratches on the cell.
Regular maintenance and ca...read more
Q10. Types of valve and their functions?
Valves are mechanical devices used to control the flow of fluids within a system. They can be classified into different types based on their design and function.
Gate valves: used to fully open or close the flow of fluid
Ball valves: have a spherical closure element to control flow
Check valves: allow flow in one direction only to prevent backflow
Butterfly valves: have a disc that rotates to control flow
Pressure relief valves: release excess pressure to prevent damage
Globe valve...read more
Q11. Design of Piped water supply Scheme to the Drawing Reading capacity of the Scheme.
Q12. How many experience with testing industry
I have 5 years of experience in the testing industry.
5 years of experience in testing industry
Proficient in manual and automated testing
Experience with various testing tools and methodologies
Strong understanding of software development lifecycle
Worked on testing projects for different industries
Q13. How to maximise the budgeted sales volume
Maximise budgeted sales volume by optimizing marketing strategies, improving sales team performance, and identifying new market opportunities.
Optimize marketing strategies to reach target audience effectively
Improve sales team performance through training and motivation
Identify new market opportunities for potential growth
Analyze sales data to understand customer behavior and preferences
Offer promotions or discounts to attract more customers
Collaborate with other departments ...read more
Q14. What is WPS ,PQR
WPS stands for Welding Procedure Specification and PQR stands for Procedure Qualification Record.
WPS is a document that provides detailed welding instructions and parameters for a specific welding job.
PQR is a record of the welding parameters used during the qualification of a welding procedure.
WPS and PQR are essential documents in the welding industry to ensure quality and consistency in welding processes.
Q15. What is the standard drying conditions
Q16. Critical of wet process
Wet process can lead to contamination and inconsistent results.
Wet process involves the use of water and other liquids which can introduce contaminants.
The process can also be affected by variations in temperature and humidity.
Examples of wet processes include washing, precipitation, and filtration.
To mitigate these issues, strict quality control measures must be in place.
Regular testing and monitoring can help ensure consistent and reliable results.
Q17. What is Work at height
Work at height refers to any work that takes place above ground level where a person could fall and injure themselves.
Work at height includes activities such as working on roofs, scaffolding, ladders, or elevated platforms.
Safety measures such as fall protection equipment and guardrails should be used when working at height.
Workers should be trained on proper procedures for working at height to prevent accidents.
Regular inspections of equipment and work areas should be conduc...read more
Q18. What do you about nabl lab Iso methods
NABL lab ISO methods are internationally recognized standards for testing and calibration laboratories.
NABL stands for National Accreditation Board for Testing and Calibration Laboratories
ISO methods ensure quality and reliability of testing procedures
Compliance with ISO methods is essential for accreditation and recognition
Examples of ISO methods include ISO 17025 for testing laboratories and ISO 15189 for medical laboratories
Q19. Defect of welding
Defects in welding can compromise the integrity of the joint and lead to structural failures.
Common welding defects include porosity, lack of fusion, cracks, and undercutting.
Porosity is caused by gas entrapment during the welding process.
Lack of fusion occurs when the weld metal fails to fuse with the base metal.
Cracks can result from excessive stress or improper cooling of the weld.
Undercutting is a groove formation along the weld toe, weakening the joint.
Proper inspection ...read more
Q20. Tolerance of UT test
The tolerance of UT test refers to the acceptable range of error in the test results.
Tolerance is typically specified in the testing standards or procedures.
It is important to ensure that the equipment used for UT testing is calibrated within the specified tolerance limits.
Deviation from the tolerance range may indicate a need for retesting or further investigation.
Examples of tolerance limits for UT testing may include +/- 1mm for wall thickness measurements.
Q21. Is method food analysis
Method food analysis involves using various techniques to analyze the composition and quality of food products.
Method food analysis includes techniques such as chromatography, spectroscopy, and microbiological testing.
It helps in determining the nutritional content, presence of contaminants, and overall quality of food products.
Examples of method food analysis include testing for pesticide residues in fruits and vegetables, determining the fat content in dairy products, and i...read more
Q22. Type of fire extinguisher
There are different types of fire extinguishers for different types of fires, such as Class A, B, C, D, and K.
Class A fire extinguishers are for ordinary combustibles like wood and paper.
Class B fire extinguishers are for flammable liquids like gasoline and oil.
Class C fire extinguishers are for electrical fires.
Class D fire extinguishers are for flammable metals.
Class K fire extinguishers are for kitchen fires involving cooking oils and fats.
Top HR Questions asked in Anthelio Healthcare Solutions
Interview Process at Anthelio Healthcare Solutions
Top Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month