i
Filter interviews by
I applied via Campus Placement and was interviewed in Feb 2024. There were 2 interview rounds.
Technical and general aptitude
Insulators are materials that resist the flow of electric current, while dielectrics are insulating materials that can be polarized by an electric field.
Insulators prevent the flow of electric current through them, while dielectrics can store electrical energy when subjected to an electric field.
Insulators have high resistivity, while dielectrics have high permittivity.
Examples of insulators include glass, rubber, and ...
Top trending discussions
posted on 22 Dec 2024
The output voltage of an AAAC Rabbit conductor is typically around 600 volts.
The output voltage of an AAAC Rabbit conductor is usually around 600 volts.
The exact output voltage may vary depending on the specific application and conditions.
It is important to consult the manufacturer's specifications for accurate information.
My execution work plan involves setting clear goals, creating a timeline, assigning tasks, monitoring progress, and adjusting as needed.
Set clear goals and objectives for the project
Create a detailed timeline with milestones and deadlines
Assign tasks to team members based on their strengths and expertise
Regularly monitor progress and make adjustments as needed
Communicate effectively with team members and stakeholders
Ut...
posted on 1 Nov 2023
I applied via AmbitionBox and was interviewed in Oct 2023. There was 1 interview round.
I have a total of 18 years of experience in power plant and oil and gas plant.
Experience includes working on various projects in power plant and oil and gas plant
Knowledge of electrical systems, equipment, and regulations in these industries
Hands-on experience in maintenance, troubleshooting, and project management
Strong understanding of safety protocols and procedures in high-risk environments
I applied via Naukri.com and was interviewed in Feb 2023. There were 2 interview rounds.
posted on 28 Jul 2023
I applied via Company Website and was interviewed in Jan 2023. There were 3 interview rounds.
posted on 17 Jan 2021
I applied via Referral
posted on 10 Feb 2024
I applied via Recruitment Consulltant and was interviewed in Jan 2024. There were 3 interview rounds.
Technical related questions and answers
My last company name
My last company CTC was $60,000 per year.
My last company CTC was $60,000 per year
CTC stands for Cost to Company
It includes salary, bonuses, benefits, and any other perks
posted on 2 Nov 2022
I applied via Recruitment Consulltant
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Substations use various equipment for power distribution and control.
Transformers: Step up or step down voltage levels.
Circuit breakers: Protect the system from overloads and faults.
Switchgear: Control and isolate electrical circuits.
Busbars: Distribute power to different parts of the substation.
Relays: Monitor and protect the system from abnormalities.
Capacitors: Improve power factor and voltage stability.
Disconnect s...
CTs, PTs, LAs, and Transformers are electrical devices used in power systems for measurement, protection, and voltage transformation.
CTs (Current Transformers) are used to measure and transform high currents into manageable levels for instruments and relays.
PTs (Potential Transformers) are used to measure and transform high voltages into low voltages for instruments and relays.
LAs (Lightning Arresters) are used to prot...
Circuit breakers are safety devices that protect electrical circuits from damage caused by overload, short circuit, or ground fault.
Circuit breakers are used to prevent damage to electrical equipment and wiring.
They interrupt the flow of electricity when there is an overload, short circuit, or ground fault.
Circuit breakers are commonly used in homes, businesses, and industrial settings.
They come in different sizes and ...
The rating of copper and aluminium cables depends on their size, insulation, and intended use.
Copper cables have higher conductivity and are therefore rated higher than aluminium cables of the same size.
The rating of a cable also depends on its insulation material and thickness.
Cables used for high voltage transmission have higher ratings than those used for low voltage applications.
For example, a 10 AWG copper cable m...
Types of protection on Transformer side line side
Overcurrent protection
Differential protection
Restricted earth fault protection
Overvoltage protection
Under voltage protection
Different types of relays are used for protection system such as overcurrent, differential, distance, and directional relays.
Overcurrent relays are used to protect against overloads and short circuits.
Differential relays are used to protect transformers and generators from internal faults.
Distance relays are used to protect transmission lines from faults.
Directional relays are used to protect against faults in specific...
Quantity Surveyor
7
salaries
| ₹4.2 L/yr - ₹8.4 L/yr |
Senior Quantity Surveyor
4
salaries
| ₹9 L/yr - ₹19 L/yr |
Graduate Engineer
3
salaries
| ₹3.6 L/yr - ₹3.6 L/yr |
Senior Manager
3
salaries
| ₹23 L/yr - ₹29 L/yr |
Procurement Engineer
3
salaries
| ₹10 L/yr - ₹10.8 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
Hindustan Construction Company